24,000 BTU mini-split heat pump · Multizone Outdoors
AireForce DXH24FMK3IH
Below average cooling efficiency and average heating efficiency for a 24,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #277 of 430 24,000 BTU mini-splits for cooling efficiency, and costs about $622 a year to run in a mixed climate like Atlanta.
- SEER2
- 21.0 Cooling efficiency over a seasonBelow average · beats 30%
- HSPF2
- 10.0 Heating efficiency over a seasonAverage · beats 43%
- EER2
- 13.3 Cooling efficiency on a 95°F dayVery good · beats 70%
- Heat at 5°F
- 21,600 BTU/h90% of its 47°F outputAverage · beats 48%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 21,600 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 12 certified pairings.
Think twice if…
- Cooling cost matters most - its SEER2 is below average for mini-splits.
Details
Specifications
| General | |
|---|---|
| Brand | AireForce |
| Also sold as | Airtemp, Gibson, Intertherm |
| Outdoor unit model | DXH24FMK3IH |
| Series | Multizone Outdoors |
| Type | Mini-split heat pump |
| Nominal size | 24,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-32 |
| Connected (smart) capable | No |
| On the market since | September 26, 2024 |
| Last certified | March 17, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 21.0 (range 18.0-21.0) |
| EER2Efficiency at 95°F outdoors | 12.0-13.3 |
| Cooling capacity | 24,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.1-10.0 |
| Capacity at 47°F | 24,000 BTU/h |
| Capacity at 17°F | 22,000-23,600 BTU/h |
| Capacity at 5°F | 21,600 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80-2.00 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| - · cold climate | 21.0 | 13.3 | 10.0 | 21,600 | 215746281 |
| - Intertherm · cold climate | 21.0 | 13.3 | 10.0 | 21,600 | 215746326 |
| - AIRTEMP · cold climate | 21.0 | 13.3 | 10.0 | 21,600 | 215746296 |
| - GIBSON · cold climate | 21.0 | 13.3 | 10.0 | 21,600 | 215746311 |
| - GIBSON · cold climate | 19.0 | 12.2 | 9.0 | 21,600 | 215746321 |
| - · cold climate | 19.0 | 12.2 | 9.0 | 21,600 | 215746291 |
| - AIRTEMP · cold climate | 19.0 | 12.2 | 9.0 | 21,600 | 215746306 |
| - Intertherm · cold climate | 19.0 | 12.2 | 9.0 | 21,600 | 215746336 |
| - · cold climate | 18.0 | 12.0 | 8.1 | 21,600 | 215746287 |
| - AIRTEMP · cold climate | 18.0 | 12.0 | 8.1 | 21,600 | 215746302 |
| - GIBSON · cold climate | 18.0 | 12.0 | 8.1 | 21,600 | 215746317 |
| - Intertherm · cold climate | 18.0 | 12.0 | 8.1 | 21,600 | 215746332 |
Yearly running cost in 10 large cities
- Phoenix, AZ$672/yr
- Miami, FL$538/yr
- Houston, TX$603/yr
- Atlanta, GA$622/yr
- Los Angeles, CA$608/yr
- New York, NY$1,501/yr
- Chicago, IL$1,221/yr
- Denver, CO$1,018/yr
- Seattle, WA$627/yr
- Minneapolis, MN$1,260/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the AireForce DXH24FMK3IH?
- The AireForce DXH24FMK3IH is rated at up to 21.0 SEER2 and 13.3 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 12 certified matchups SEER2 ranges from 18.0-21.0.
- Is the AireForce DXH24FMK3IH good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 21,600 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the AireForce DXH24FMK3IH cost to run per year?
- At its rated efficiency it costs about $538-$1,501 a year in electricity in large U.S. cities, depending on climate and local rates - for example $672 in Phoenix and $1,260 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- What refrigerant does the AireForce DXH24FMK3IH use?
- It uses R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 24,000 BTU models
- 1HVAC SC-27Z-HH-M4B · cold climate21.0 SEER2 · 10.0 HSPF2
- Blueridge BMKH24MC · cold climate21.0 SEER2 · 10.0 HSPF2
- Innovair QOS24H2BH0A · cold climate21.0 SEER2 · 10.5 HSPF2
- COSTWAY FP10524US-12WH21.0 SEER2 · 10.0 HSPF2
- Hisense AOU-24U3T25U · cold climate21.0 SEER2 · 10.5 HSPF2
- COSTWAY FP10790US-12BK21.0 SEER2 · 10.0 HSPF2
- Guardian UPC24CN23STG1 · cold climate21.0 SEER2 · 10.5 HSPF2
- Daikin 3MXM24AVJU · cold climate21.0 SEER2 · 10.0 HSPF2
See all 430 24,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of March 17, 2026. How we use the data.