Below average cooling efficiency and average heating efficiency for a 24,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #273 of 430 24,000 BTU mini-splits for cooling efficiency, and costs about $603 a year to run in a mixed climate like Atlanta.
- SEER2
- 21.0 Cooling efficiency over a seasonBelow average · beats 30%
- HSPF2
- 10.5 Heating efficiency over a seasonAverage · beats 61%
- EER2
- 12.0 Cooling efficiency on a 95°F dayBelow average · beats 25%
- Heat at 5°F
- 24,200 BTU/h100% of its 47°F outputAverage · beats 48%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 24,200 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 15 certified pairings.
Think twice if…
- Cooling cost matters most - its SEER2 is below average for mini-splits.
Details
Specifications
| General | |
|---|---|
| Brand | Guardian |
| Also sold as | Luxaire, Coleman |
| Outdoor unit model | UPC24CN23STG1 |
| Series | UPAC |
| Type | Mini-split heat pump |
| Nominal size | 24,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | November 1, 2024 |
| Last certified | June 12, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 21.0 (range 18.0-21.0) |
| EER2Efficiency at 95°F outdoors | 11.7-12.0 |
| Cooling capacity | 18,000-24,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.5-10.5 |
| Capacity at 47°F | 18,000-24,000 BTU/h |
| Capacity at 17°F | 16,600-20,200 BTU/h |
| Capacity at 5°F | 19,500-24,200 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80-2.00 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with UNI24HW23STG1 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| UNI24HW23STG1 GUARDIAN | 21.0 | 12.0 | 10.0 | 24,000 | 216017246 |
| UNI24HW23STG1 Coleman | 21.0 | 12.0 | 10.0 | 24,000 | 216572160 |
| UNI24HW23STG1 LUXAIRE | 21.0 | 12.0 | 10.0 | 24,000 | 216572171 |
| UNI24CS23STG1 GUARDIAN · cold climate | 20.0 | 12.0 | 10.5 | 24,000 | 216019853 |
| UNI24CS23STG1 Coleman · cold climate | 20.0 | 12.0 | 10.5 | 24,000 | 216566109 |
| UNI24CS23STG1 LUXAIRE · cold climate | 20.0 | 12.0 | 10.5 | 24,000 | 216566111 |
| UNI24DT23STG1 GUARDIAN · cold climate | 19.0 | 11.7 | 9.5 | 24,000 | 216445266 |
| UNI24DT23STG1 LUXAIRE · cold climate | 19.0 | 11.7 | 9.5 | 24,000 | 216566115 |
| UNI24DT23STG1 Coleman · cold climate | 19.0 | 11.7 | 9.5 | 24,000 | 216566113 |
| JHE18B5AB2SS1 · cold climate | 18.0 | 12.0 | 9.5 | 19,500 | 217050611 |
| JHE24B5AC2SS1 · cold climate | 18.0 | 11.7 | 9.5 | 24,200 | 217050612 |
| JHE18B5AB2SS1 · cold climate | 18.0 | 12.0 | 9.5 | 19,500 | 217050614 |
| JHE24B5AC2SS1 · cold climate | 18.0 | 11.7 | 9.5 | 24,200 | 217050615 |
| JHE18B5AB2SS1 · cold climate | 18.0 | 12.0 | 9.5 | 19,500 | 217050617 |
| JHE24B5AC2SS1 · cold climate | 18.0 | 11.7 | 9.5 | 24,200 | 217050618 |
Yearly running cost in 10 large cities
- Phoenix, AZ$663/yr
- Miami, FL$537/yr
- Houston, TX$594/yr
- Atlanta, GA$603/yr
- Los Angeles, CA$587/yr
- New York, NY$1,442/yr
- Chicago, IL$1,171/yr
- Denver, CO$974/yr
- Seattle, WA$599/yr
- Minneapolis, MN$1,206/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Guardian UPC24CN23STG1?
- The Guardian UPC24CN23STG1 is rated at up to 21.0 SEER2 and 12.0 EER2 for cooling and up to 10.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 15 certified matchups SEER2 ranges from 18.0-21.0.
- Is the Guardian UPC24CN23STG1 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 24,200 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the Guardian UPC24CN23STG1 cost to run per year?
- At its rated efficiency it costs about $537-$1,442 a year in electricity in large U.S. cities, depending on climate and local rates - for example $663 in Phoenix and $1,206 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Guardian UPC24CN23STG1?
- ENERGY STAR lists 15 certified combinations for this outdoor unit. The highest-rated ones use GUARDIAN UNI24HW23STG1, Coleman UNI24HW23STG1, LUXAIRE UNI24HW23STG1.
- What refrigerant does the Guardian UPC24CN23STG1 use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 24,000 BTU models
- York YRACXJ24WHBA · cold climate21.0 SEER2 · 11.0 HSPF2
- Hisense AOU-24U3T25U · cold climate21.0 SEER2 · 10.5 HSPF2
- York YRACGJ24WHAA · cold climate21.0 SEER2 · 11.0 HSPF2
- Innovair QOS24H2BH0A · cold climate21.0 SEER2 · 10.5 HSPF2
- Hitachi RAC-XJ24WHAA · cold climate21.0 SEER2 · 11.0 HSPF2
- 1HVAC SC-27Z-HH-M4B · cold climate21.0 SEER2 · 10.0 HSPF2
- Deye DWLC2-24KR2(US) · cold climate21.0 SEER2 · 11.0 HSPF2
- AireForce DXH24FMK3IH · cold climate21.0 SEER2 · 10.0 HSPF2
See all 430 24,000 BTU mini-splits, ranked