24,000 BTU mini-split heat pump · airHome 800
Hitachi RAC-XJ24WHAA
Below average cooling efficiency and very good heating efficiency for a 24,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #270 of 430 24,000 BTU mini-splits for cooling efficiency, and costs about $586 a year to run in a mixed climate like Atlanta.
- SEER2
- 21.0 Cooling efficiency over a seasonBelow average · beats 30%
- HSPF2
- 11.0 Heating efficiency over a seasonVery good · beats 75%
- EER2
- 12.5 Cooling efficiency on a 95°F dayAverage · beats 44%
- Heat at 5°F
- 17,900 BTU/h75% of its 47°F outputBelow average · beats 27%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 17,900 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 75% of mini-splits.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Cooling cost matters most - its SEER2 is below average for mini-splits.
Details
Specifications
| General | |
|---|---|
| Brand | Hitachi |
| Outdoor unit model | RAC-XJ24WHAA |
| Series | airHome 800 |
| Type | Mini-split heat pump |
| Nominal size | 24,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-32 |
| Connected (smart) capable | No |
| On the market since | November 22, 2024 |
| Last certified | March 4, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 21.0 (range 21.0) |
| EER2Efficiency at 95°F outdoors | 12.5 |
| Cooling capacity | 24,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 11.0 |
| Capacity at 47°F | 24,000 BTU/h |
| Capacity at 17°F | 16,000 BTU/h |
| Capacity at 5°F | 17,900 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.90 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with RAK-XJ24PHAA at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| RAK-XJ24PHAA · cold climate | 21.0 | 12.5 | 11.0 | 17,900 | 216011944 |
Yearly running cost in 10 large cities
- Phoenix, AZ$655/yr
- Miami, FL$536/yr
- Houston, TX$587/yr
- Atlanta, GA$586/yr
- Los Angeles, CA$568/yr
- New York, NY$1,389/yr
- Chicago, IL$1,126/yr
- Denver, CO$935/yr
- Seattle, WA$573/yr
- Minneapolis, MN$1,156/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Hitachi RAC-XJ24WHAA?
- The Hitachi RAC-XJ24WHAA is rated at up to 21.0 SEER2 and 12.5 EER2 for cooling and up to 11.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the Hitachi RAC-XJ24WHAA good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 17,900 BTU/h at 5°F with a COP of 1.90, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
- How much does the Hitachi RAC-XJ24WHAA cost to run per year?
- At its rated efficiency it costs about $536-$1,389 a year in electricity in large U.S. cities, depending on climate and local rates - for example $655 in Phoenix and $1,156 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Hitachi RAC-XJ24WHAA?
- ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses RAK-XJ24PHAA.
- What refrigerant does the Hitachi RAC-XJ24WHAA use?
- It uses R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 24,000 BTU models
- Deye DWLC2-24KR2(US) · cold climate21.0 SEER2 · 11.0 HSPF2
- York YRACGJ24WHAA · cold climate21.0 SEER2 · 11.0 HSPF2
- ECO AC EHH-O24BB · cold climate21.0 SEER2 · 11.2 HSPF2
- York YRACXJ24WHBA · cold climate21.0 SEER2 · 11.0 HSPF2
- York YPAS24BLFASDQ1 · cold climate21.0 SEER2 · 12.2 HSPF2
- Guardian UPC24CN23STG1 · cold climate21.0 SEER2 · 10.5 HSPF2
- Napoleon NDHAS26BA-24-O · cold climate21.0 SEER2 · 13.5 HSPF2
- Hisense AOU-24U3T25U · cold climate21.0 SEER2 · 10.5 HSPF2
See all 430 24,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of March 4, 2025. How we use the data.