2-ton central heat pump · Crossover Heat Pump

Airquest D5CUHAH24AAK+KSAIC0701230

Average cooling efficiency and very good heating efficiency for a 2-ton central heat pump, and certified for cold climates.

Ranks #160 of 331 2 ton central heat pumps for cooling efficiency, and costs about $649 a year to run in a mixed climate like Atlanta.

SEER2
18.0 Cooling efficiency over a season
Average · beats 66%
HSPF2
9.5 Heating efficiency over a season
Very good · beats 70%
EER2
11.0 Cooling efficiency on a 95°F day
Below average · beats 23%
Heat at 5°F
20,600 BTU/h85% of its 47°F output
Average · beats 51%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 20,600 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 4,017 certified pairings.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandAirquest
Also sold asSmart Comfort, Tempstar, Keeprite, Day & Night, Comfortmaker, Arcoaire, Heil, Viessmann
Outdoor unit modelD5CUHAH24AAK+KSAIC0701230
SeriesCrossover Heat Pump
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJune 27, 2024
Last certifiedJuly 17, 2026
Cooling
SEER2Seasonal efficiency, higher is better18.0 (range 15.2-18.0)
EER2Efficiency at 95°F outdoors10.0-11.0
Cooling capacity22,600-25,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1-9.5
Capacity at 47°F22,200-25,800 BTU/h
Capacity at 17°F16,800-18,700 BTU/h
Capacity at 5°F18,700-20,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.85-2.06
ENERGY STAR cold climateYes
Heating output as it gets colder85% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EA*5X25M17A at the standard test temperatures, in BTU/h:

Certified matchups4,017 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 4,017 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
EA*5X25M17A · cold climate*80MSU0601716A*18.011.09.019,100218486528
EA*5X25M17A · cold climate*80MSU0601716A*18.011.09.019,100218486527
EA*5X25M17A · cold climate*80MSU0601716A*18.011.09.019,100218486526
EA*5X25M17A · cold climate*80MSU0601716A*18.011.09.019,100218486525
EA*5X25M17A · cold climate*80MSU0601716A*18.011.09.019,100218486524
EA*5X25M17A · cold climate*80MSU0601716A*18.011.09.019,100218486523
EA*5X25M17A · cold climate*80MSU0601716A*18.011.09.019,100218486522
FTMA5B36L0C · cold climate-18.011.09.019,000218488453
FTMA5B36L0C · cold climate-18.011.09.019,000218488452
FTMA5B36L0C · cold climate-18.011.09.019,000218488451
FTMA5B36L0C · cold climate-18.011.09.019,000218488450
FTMA5B36L0C · cold climate-18.011.09.019,000218488449
FTMA5B36L0C · cold climate-18.011.09.019,000218488448
FTMA5B36L0C · cold climate-18.011.09.019,000218488447
EA*5X25M17A · cold climate*80MSU0601716A*18.011.09.019,100218681058
FTMA5B36L0C · cold climate-18.011.09.019,000218681333
EA*5X25M17A · cold climate*80VTL0451412B*18.011.08.518,900218486535
EA*5X25M17A · cold climate*80VTL0451412B*18.011.08.518,900218486534
EA*5X25M17A · cold climate*80VTL0451412B*18.011.08.518,900218486533
EA*5X25M17A · cold climate*80VTL0451412B*18.011.08.518,900218486532
EA*5X25M17A · cold climate*80VTL0451412B*18.011.08.518,900218486531
EA*5X25M17A · cold climate*80VTL0451412B*18.011.08.518,900218486530
EA*5X25M17A · cold climate*80VTL0451412B*18.011.08.518,900218486529
EA*5X25M17A · cold climate*80VSL0451412B*18.011.08.518,900218486493
EA*5X25M17A · cold climate*80VSL0451412B*18.011.08.518,900218486492
EA*5X25M17A · cold climate*80VSL0451412B*18.011.08.518,900218486491
EA*5X25M17A · cold climate*80VSL0451412B*18.011.08.518,900218486490
EA*5X25M17A · cold climate*80VSL0451412B*18.011.08.518,900218486489
EA*5X25M17A · cold climate*80VSL0451412B*18.011.08.518,900218486488
EA*5X25M17A · cold climate*80VSL0451412B*18.011.08.518,900218486487
EA*5X25M17A · cold climate*80VTL0451412B*18.011.08.518,900218681059
EA*5X25M17A · cold climate*80VSL0451412B*18.011.08.518,900218681053
FTMA5X24L0B · cold climate-17.511.09.519,000218475399
FTMA5X24L0B · cold climate-17.511.09.519,000218475398
FTMA5X24L0B · cold climate-17.511.09.519,000218475397
FTMA5X24L0B · cold climate-17.511.09.519,000218475396
FTMA5X24L0B · cold climate-17.511.09.519,000218475395
FTMA5X24L0B · cold climate-17.511.09.519,000218475394
FTMA5X24L0B · cold climate-17.511.09.519,000218475393
FTMA5X24L0B · cold climate-17.511.09.519,000218680171
EA*5X37M21A · cold climate*95MSU1002122A*17.511.09.019,000218487382
EA*5X37M21A · cold climate*95MSU1002122A*17.511.09.019,000218487381
EA*5X37M21A · cold climate*95MSU1002122A*17.511.09.019,000218487380
EA*5X37M21A · cold climate*95MSU1002122A*17.511.09.019,000218487379
EA*5X37M21A · cold climate*95MSU1002122A*17.511.09.019,000218487378
EA*5X37M21A · cold climate*95MSU1002122A*17.511.09.019,000218487377
EA*5X37M21A · cold climate*95MSU1002122A*17.511.09.019,000218487376
EA*5X37M17A · cold climate*80MSU0601716A*17.511.09.019,200218487102
EA*5X37M17A · cold climate*80MSU0601716A*17.511.09.019,200218487101
EA*5X37M17A · cold climate*80MSU0601716A*17.511.09.019,200218487100
EA*5X37M17A · cold climate*80MSU0601716A*17.511.09.019,200218487099
EA*5X37M17A · cold climate*80MSU0601716A*17.511.09.019,200218487098
EA*5X37M17A · cold climate*80MSU0601716A*17.511.09.019,200218487097
EA*5X37M17A · cold climate*80MSU0601716A*17.511.09.019,200218487096
EA*5X37M17A · cold climate*80VSL0701716B*17.511.09.019,300218487081
EA*5X37M17A · cold climate*80VSL0701716B*17.511.09.019,300218487080
EA*5X37M17A · cold climate*80VSL0701716B*17.511.09.019,300218487079
EA*5X37M17A · cold climate*80VSL0701716B*17.511.09.019,300218487078
EA*5X37M17A · cold climate*80VSL0701716B*17.511.09.019,300218487077
EA*5X37M17A · cold climate*80VSL0701716B*17.511.09.019,300218487076
Yearly running cost in 10 large cities$609-$1,528

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Airquest D5CUHAH24AAK+KSAIC0701230?
The Airquest D5CUHAH24AAK+KSAIC0701230 is rated at up to 18.0 SEER2 and 11.0 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 4017 certified matchups SEER2 ranges from 15.2-18.0.
Is the Airquest D5CUHAH24AAK+KSAIC0701230 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 20,600 BTU/h at 5°F with a COP of 2.06, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
How much does the Airquest D5CUHAH24AAK+KSAIC0701230 cost to run per year?
At its rated efficiency it costs about $609-$1,528 a year in electricity in large U.S. cities, depending on climate and local rates - for example $737 in Phoenix and $1,266 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Airquest D5CUHAH24AAK+KSAIC0701230?
ENERGY STAR lists 4017 certified combinations for this outdoor unit. The highest-rated ones use EA*5X25M17A, FTMA5B36L0C, FTMA5X24L0B.
What refrigerant does the Airquest D5CUHAH24AAK+KSAIC0701230 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $724/yrYou save $469/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Airquest D5CUHAH24AAK+KSAIC0701230
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$724
Current system, per year
$1,193
You save per year
$469
Payback
19.2 years
Net after 10 years
-$4,306

Cooling $458Heating $266Electricity used: 4,525 kWhSaved vs. a minimum-efficiency heat pump: $189

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 17, 2026. How we use the data.