36,000 BTU mini-split heat pump · DLC-series
Airquest DLCMHBH36DAK
Below average cooling efficiency and average heating efficiency for a 36,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #147 of 205 36,000 BTU mini-splits for cooling efficiency, and costs about $966 a year to run in a mixed climate like Atlanta.
- SEER2
- 20.0 Cooling efficiency over a seasonBelow average · beats 18%
- HSPF2
- 10.0 Heating efficiency over a seasonAverage · beats 43%
- EER2
- 12.5 Cooling efficiency on a 95°F dayAverage · beats 44%
- Heat at 5°F
- 36,000 BTU/h97% of its 47°F outputBelow average · beats 27%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 36,000 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 36 certified pairings.
Think twice if…
- Cooling cost matters most - its SEER2 is below average for mini-splits.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Airquest |
| Also sold as | Smart Comfort, Tempstar, Midea, Kenmore, Keeprite, Heil, Day & Night, Comfortmaker, Arcoaire, LPS Legacy, Viessmann |
| Outdoor unit model | DLCMHBH36DAK |
| Series | DLC-series |
| Type | Mini-split heat pump |
| Nominal size | 36,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | January 1, 2018 |
| Last certified | March 4, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 20.0 (range 19.0-20.0) |
| EER2Efficiency at 95°F outdoors | 11.7-12.5 |
| Cooling capacity | 36,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.7-10.0 |
| Capacity at 47°F | 37,000 BTU/h |
| Capacity at 17°F | 35,000 BTU/h |
| Capacity at 5°F | 33,000-36,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.70-1.90 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| - ARCOAIRE · cold climate | 20.0 | 12.5 | 9.7 | 36,000 | 207643002 |
| - COMFORTMAKER · cold climate | 20.0 | 12.5 | 9.7 | 36,000 | 207643023 |
| - DAY & NIGHT · cold climate | 20.0 | 12.5 | 9.7 | 36,000 | 207643044 |
| - HEIL · cold climate | 20.0 | 12.5 | 9.7 | 36,000 | 207643065 |
| - KENMORE · cold climate | 20.0 | 12.5 | 9.7 | 36,000 | 207643107 |
| - TEMPSTAR · cold climate | 20.0 | 12.5 | 9.7 | 36,000 | 207643149 |
| - SMART COMFORT · cold climate | 20.0 | 12.5 | 9.7 | 36,000 | 207643170 |
| - AIRQUEST · cold climate | 20.0 | 12.5 | 9.7 | 36,000 | 207643191 |
| - LPS Legacy · cold climate | 20.0 | 12.5 | 9.7 | 36,000 | 211756577 |
| - Viessmann · cold climate | 20.0 | 12.5 | 9.7 | 36,000 | 215569824 |
| - MIDEA · cold climate | 20.0 | 12.5 | 9.7 | 36,000 | 207643128 |
| - KEEPRITE · cold climate | 20.0 | 12.5 | 9.7 | 36,000 | 207643086 |
| - LPS Legacy · cold climate | 19.5 | 12.1 | 9.9 | 34,400 | 211756610 |
| - AIRQUEST · cold climate | 19.5 | 12.1 | 9.9 | 34,400 | 207643193 |
| - SMART COMFORT · cold climate | 19.5 | 12.1 | 9.9 | 34,400 | 207643172 |
| - KENMORE · cold climate | 19.5 | 12.1 | 9.9 | 34,400 | 207643109 |
| - TEMPSTAR · cold climate | 19.5 | 12.1 | 9.9 | 34,400 | 207643151 |
| - MIDEA · cold climate | 19.5 | 12.1 | 9.9 | 34,400 | 207643130 |
| - KEEPRITE · cold climate | 19.5 | 12.1 | 9.9 | 34,400 | 207643088 |
| - HEIL · cold climate | 19.5 | 12.1 | 9.9 | 34,400 | 207643067 |
| - COMFORTMAKER · cold climate | 19.5 | 12.1 | 9.9 | 34,400 | 207643025 |
| - DAY & NIGHT · cold climate | 19.5 | 12.1 | 9.9 | 34,400 | 207643046 |
| - ARCOAIRE · cold climate | 19.5 | 12.1 | 9.9 | 34,400 | 207643004 |
| - Viessmann · cold climate | 19.5 | 12.1 | 9.9 | 34,400 | 215569883 |
| - AIRQUEST | 19.0 | 11.7 | 10.0 | 33,000 | 207643192 |
| - SMART COMFORT | 19.0 | 11.7 | 10.0 | 33,000 | 207643171 |
| - TEMPSTAR | 19.0 | 11.7 | 10.0 | 33,000 | 207643150 |
| - MIDEA | 19.0 | 11.7 | 10.0 | 33,000 | 207643129 |
| - KENMORE | 19.0 | 11.7 | 10.0 | 33,000 | 207643108 |
| - KEEPRITE | 19.0 | 11.7 | 10.0 | 33,000 | 207643087 |
| - HEIL | 19.0 | 11.7 | 10.0 | 33,000 | 207643066 |
| - DAY & NIGHT | 19.0 | 11.7 | 10.0 | 33,000 | 207643045 |
| - COMFORTMAKER | 19.0 | 11.7 | 10.0 | 33,000 | 207643024 |
| - ARCOAIRE | 19.0 | 11.7 | 10.0 | 33,000 | 207643003 |
| - LPS Legacy | 19.0 | 11.7 | 10.0 | 33,000 | 211756519 |
| - Viessmann | 19.0 | 11.7 | 10.0 | 33,000 | 215569825 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,052/yr
- Miami, FL$847/yr
- Houston, TX$943/yr
- Atlanta, GA$966/yr
- Los Angeles, CA$943/yr
- New York, NY$2,323/yr
- Chicago, IL$1,889/yr
- Denver, CO$1,572/yr
- Seattle, WA$968/yr
- Minneapolis, MN$1,947/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Airquest DLCMHBH36DAK?
- The Airquest DLCMHBH36DAK is rated at up to 20.0 SEER2 and 12.5 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 36 certified matchups SEER2 ranges from 19.0-20.0.
- Is the Airquest DLCMHBH36DAK good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 36,000 BTU/h at 5°F with a COP of 1.90, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
- How much does the Airquest DLCMHBH36DAK cost to run per year?
- At its rated efficiency it costs about $847-$2,323 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,052 in Phoenix and $1,947 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- What refrigerant does the Airquest DLCMHBH36DAK use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 36,000 BTU models
- Lennox VPC036H5M-3P · cold climate20.0 SEER2 · 10.1 HSPF2
- Blueridge BMM36HHC · cold climate20.0 SEER2 · 10.0 HSPF2
- Carrier 37VMB036HDS3-1 · cold climate20.0 SEER2 · 10.1 HSPF2
- ComfortStar C32-MZ-5 · cold climate20.0 SEER2 · 10.0 HSPF2
- Midea MDV-V36WMN10T-H · cold climate20.0 SEER2 · 10.2 HSPF2
- Guardian UPC36CN23STG1 · cold climate20.0 SEER2 · 10.0 HSPF2
- Mainline ML36HP230LCM-O · cold climate20.0 SEER2 · 10.3 HSPF2
- Hisense AOU-36U3T25U · cold climate20.0 SEER2 · 10.0 HSPF2
See all 205 36,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of March 4, 2025. How we use the data.