HVAC Rated

3-ton central heat pump · Platinum 19

American Standard 4A6L9036A1

Average cooling and heating efficiency for a 3-ton central heat pump, but not rated for cold climates.

Ranks #113 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,042 a year to run in a mixed climate like Atlanta.

SEER2
18.0 Cooling efficiency over a season
Average · beats 66%
HSPF2
8.7 Heating efficiency over a season
Average · beats 47%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
- Not reported by the maker

A good fit if…

  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 10 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications3 ton, R-410A
General
BrandAmerican Standard
Outdoor unit model4A6L9036A1
SeriesPlatinum 19
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceJanuary 1, 2023
Last certifiedMay 3, 2023
Cooling
SEER2Seasonal efficiency, higher is better18.0 (range 17.5-18.0)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity37,400-38,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-8.7
Capacity at 47°F33,000-33,600 BTU/h
Capacity at 17°F23,000-23,600 BTU/h
Capacity at 5°F-
COP at 5°F2.0 = twice as efficient as a space heater-
ENERGY STAR cold climateNo
Heating output as it gets colder

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 4TXCD010DS3 at the standard test temperatures, in BTU/h:

Certified matchups10 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
4TXCD010DS3S8V2D120M5PCA18.012.08.7-210691978
4PX*DU60BS3S8V2D120M5PCA18.012.08.7-210691964
4TXCC009DS3S8V2C100M5PCA17.511.78.7-210691976
4PX*CU60BS3S8V2C100M5PCA17.511.78.7-210691961
4PX*DU48BS3S8V2D120M5PCA17.511.78.7-210691963
4TXCD008DS3S8V2D120M5PCA17.511.78.7-210691977
4TXCC009DS3S8V2C080M5PCA17.511.78.7-210691975
4PX*CU60BS3S8V2C080M5PCA17.511.78.7-210691960
4PX*CD60BS3S8V2C100M5PCA17.511.78.5-210691953
4PX*CD60BS3S8V2C080M5PCA17.511.78.5-210691952
Yearly running cost in 10 large cities$979-$2,452

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the American Standard 4A6L9036A1?
The American Standard 4A6L9036A1 is rated at up to 18.0 SEER2 and 12.0 EER2 for cooling and up to 8.7 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 10 certified matchups SEER2 ranges from 17.5-18.0.
Is the American Standard 4A6L9036A1 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
How much does the American Standard 4A6L9036A1 cost to run per year?
At its rated efficiency it costs about $979-$2,452 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,184 in Phoenix and $2,031 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the American Standard 4A6L9036A1?
ENERGY STAR lists 10 certified combinations for this outdoor unit. The highest-rated ones use 4TXCD010DS3, 4PX*DU60BS3, 4TXCC009DS3.
What refrigerant does the American Standard 4A6L9036A1 use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,163/yrYou save $704/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump American Standard 4A6L9036A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,163
Current system, per year
$1,867
You save per year
$704
Payback
19.9 years
Net after 10 years
-$6,959

Cooling $735Heating $427Electricity used: 7,267 kWhSaved vs. a minimum-efficiency heat pump: $259

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 3, 2023. How we use the data.