3-ton central heat pump · PLATINUM 20
American Standard 4A6V0X36A1
Excellent cooling efficiency and average heating efficiency for a 3-ton central heat pump, and certified for cold climates.
Ranks #19 of 302 3 ton central heat pumps for cooling efficiency, and costs about $931 a year to run in a mixed climate like Atlanta.
- SEER2
- 20.5 Cooling efficiency over a seasonExcellent · beats 96%
- HSPF2
- 8.7 Heating efficiency over a seasonAverage · beats 47%
- EER2
- 12.7 Cooling efficiency on a 95°F dayVery good · beats 84%
- Heat at 5°F
- 22,400 BTU/h63% of its 47°F outputBelow average · beats 25%
A good fit if…
- You want low cooling bills - its SEER2 beats 96% of central heat pumps.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 22,400 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 212 certified pairings.
Think twice if…
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | American Standard |
| Outdoor unit model | 4A6V0X36A1 |
| Series | PLATINUM 20 |
| Type | Central heat pump |
| Nominal size | 3 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | January 1, 2023 |
| Last certified | September 24, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 20.5 (range 17.5-20.5) |
| EER2Efficiency at 95°F outdoors | 11.2-12.7 |
| Cooling capacity | 32,000-36,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.0-8.7 |
| Capacity at 47°F | 29,800-35,400 BTU/h |
| Capacity at 17°F | 24,400-29,000 BTU/h |
| Capacity at 5°F | 19,000-22,400 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.60-1.92 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 4PX*CU48BS3 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 212 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| 4PX*CU48BS3 | *UD2C100ACV5 | 20.5 | 12.7 | 8.7 | 20,400 | 207590662 |
| 4PX*CU48BS3 | S8V2C100M5PDA | 20.5 | 12.5 | 8.7 | 20,400 | 211081411 |
| 4PX*CU48BS3 | *UD2C080ACV4 | 20.5 | 12.7 | 8.7 | 20,200 | 207590661 |
| 4PX*CU48BS3 | S9V2C100U4VSA+RP | 20.5 | 12.7 | 8.7 | 20,200 | 207590136 |
| TEM8A0C42V41+TDR | - | 20.5 | 12.5 | 8.7 | 20,200 | 207590054 |
| TEM8A0C36V31+TDR | - | 20.5 | 12.5 | 8.7 | 20,200 | 207590053 |
| 4PX*CU48BS3 | S8V2C100M5PCA | 20.5 | 12.5 | 8.7 | 20,400 | 210692050 |
| 4PX*CU42BS3 | *UD2C080ACV4 | 20.5 | 12.7 | 8.7 | 20,200 | 211597751 |
| 4PX*CU42BS3 | S9V2C100U4VSA+RP | 20.5 | 12.7 | 8.7 | 20,200 | 210653002 |
| 4PX*CU48BS3 | S8V2C100M5PDB | 20.5 | 12.5 | 8.7 | 20,400 | 214253024 |
| 4PX*CU48BS3 | S8V2C100M5PCB | 20.5 | 12.5 | 8.7 | 20,400 | 214253026 |
| 4PX*CU48BS3 | S9V2C080U5PSC+RP | 20.5 | 12.7 | 8.7 | 21,800 | 214639468 |
| 4TXCC009DS3 | *UD2C080ACV4 | 20.5 | 12.7 | 8.7 | 21,400 | 214655474 |
| 4PX*CD42BS3 | S9V2C100D4VSA+RP | 20.5 | 12.7 | 8.2 | 20,000 | 210652999 |
| 4PX*CD42BS3+HORIZ-RT | *UD2C100ACV5 | 20.5 | 12.7 | 8.2 | 20,400 | 211289071 |
| 4PX*BD42BS3 | *DD2B060ACV3 | 20.5 | 12.5 | 8.2 | 20,600 | 211597741 |
| 4PX*CD42BS3+HORIZ-RT | *UD2C080ACV4 | 20.5 | 12.7 | 8.2 | 20,000 | 211597750 |
| 4PX*BD42BS3 | S9V2B080D4VSA+RP | 20.5 | 12.5 | 8.1 | 20,200 | 210173714 |
| 4PX*BD42BS3 | S9V2B060D3PSB+RP | 20.5 | 12.5 | 8.1 | 20,000 | 207590244 |
| 4PX*BD42BS3 | S9V2B080D4PSB+RP | 20.5 | 12.5 | 8.1 | 20,200 | 207590246 |
| 4PX*CD42BS3 | *DD2C100ACV5 | 20.5 | 12.7 | 8.1 | 20,200 | 207590253 |
| 4PX*BD42BS3 | S9V2B040D3PSB+RP | 20.5 | 12.5 | 8.1 | 20,200 | 207590242 |
| 4PX*BD42BS3 | S9V2B080D4VSB+RP | 20.5 | 12.5 | 8.1 | 20,200 | 214638802 |
| 4PX*CD36BS3 | S9V2C100D4VSA+RP | 20.5 | 12.0 | 8.0 | 20,400 | 207590133 |
| 4PX*CD36BS3+HORIZ-RT | *UD2C080ACV4 | 20.5 | 12.0 | 8.0 | 20,400 | 211597749 |
| TAMXB0B30V31 | - | 20.0 | 12.5 | 8.7 | 20,400 | 210929575 |
| 4PX*CU42BS3 | *UD2C100ACV5 | 20.0 | 12.7 | 8.7 | 20,400 | 211289072 |
| 4PX*CU42BS3 | S9V2C080U5PSC+RP | 20.0 | 12.7 | 8.7 | 21,800 | 214639466 |
| 4TXCB006DS3 | S8V2B080M4PCB | 20.0 | 12.0 | 8.7 | 22,200 | 214717215 |
| 4PX*BU36BS3 | S9V2B040U3PSB+RP | 20.0 | 12.0 | 8.5 | 20,400 | 210652976 |
| 4PX*BU36BS3 | S9V2B080U4PSB+RP | 20.0 | 12.0 | 8.5 | 20,200 | 210610549 |
| 4PX*CU42BS3 | S8V2C100M5PDA | 20.0 | 12.5 | 8.5 | 20,600 | 211081410 |
| 4TXCB004DS3 | S9V2B080U4VSA+RP | 20.0 | 12.0 | 8.5 | 20,200 | 209326025 |
| 4TXCC005DS3 | *UD2C100ACV5 | 20.0 | 12.0 | 8.5 | 20,400 | 207590683 |
| 4TXCC005DS3 | *UD2C080ACV4 | 20.0 | 12.0 | 8.5 | 20,200 | 207590682 |
| 4TXCB004DS3 | *UHMB080ACV3 | 20.0 | 12.0 | 8.5 | 20,400 | 207590676 |
| 4PX*CU36BS3 | *UD2C080ACV4 | 20.0 | 12.0 | 8.5 | 20,200 | 207590660 |
| 4PX*BU36BS3 | *UHMB060ACV3 | 20.0 | 12.0 | 8.5 | 20,400 | 207590651 |
| 4PX*BU36BS3 | S9V2B080U4VSA+RP | 20.0 | 12.0 | 8.5 | 20,200 | 207590621 |
| 4PX*CU36BS3 | *UD2C100ACV5 | 20.0 | 12.0 | 8.5 | 20,400 | 207590658 |
| 4PX*CU48BS3 | S8V2C080M5PDA | 20.0 | 12.5 | 8.5 | 20,400 | 211081412 |
| 4PX*BU36BS3 | *UHMB080ACV3 | 20.0 | 12.0 | 8.5 | 20,400 | 207590648 |
| 4TXCC005DS3 | S9V2C100U4VSA+RP | 20.0 | 12.0 | 8.5 | 20,200 | 207590145 |
| 4PX*CU36BS3 | S9V2C100U4VSA+RP | 20.0 | 12.0 | 8.5 | 20,200 | 207590135 |
| 4PX*BU36BS3 | S9V2B040U3VSA+RP | 20.0 | 12.0 | 8.5 | 20,400 | 207590129 |
| 4PX*CU48BS3 | S8V2C080M5PCA | 20.0 | 12.5 | 8.5 | 20,400 | 210692051 |
| 4PX*CU42BS3 | S8V2C100M5PCA | 20.0 | 12.5 | 8.5 | 20,600 | 210692048 |
| 4PX*CU42BS3 | S8V2C100M5PCB | 20.0 | 12.5 | 8.5 | 20,600 | 214253018 |
| 4PX*CU42BS3 | S8V2C100M5PDB | 20.0 | 12.5 | 8.5 | 20,600 | 214253020 |
| 4PX*CU48BS3 | S8V2C080M5PCB | 20.0 | 12.5 | 8.5 | 20,400 | 214253028 |
| 4PX*CU48BS3 | S8V2C080M5PDB | 20.0 | 12.5 | 8.5 | 20,400 | 214253030 |
| 4PX*CU36BS3 | *UHMC100CCV4 | 20.0 | 12.0 | 8.5 | 20,200 | 214250652 |
| 4TXCB004DS3 | *UHMB080CCV3 | 20.0 | 12.0 | 8.5 | 20,400 | 214250658 |
| 4TXCC005DS3 | *UHMC100CCV4 | 20.0 | 12.0 | 8.5 | 20,200 | 214250666 |
| 4PX*BU36BS3 | S9V2B040U3VSB+RP | 20.0 | 12.0 | 8.5 | 20,400 | 214638804 |
| 4PX*BU36BS3 | S9V2B080U4VSB+RP | 20.0 | 12.0 | 8.5 | 20,200 | 214638806 |
| 4TXCB004DS3 | S9V2B080U4VSB+RP | 20.0 | 12.0 | 8.5 | 20,200 | 214638822 |
| 4PX*BD42BS3 | S9V2B080D4PSC+RP | 20.0 | 12.5 | 8.5 | 22,000 | 214639436 |
| 4PX*BD42BS3 | S9V2B040D3PSC+RP | 20.0 | 12.5 | 8.5 | 22,400 | 214639438 |
| 4PX*BD42BS3+HORIZ-RT | S9V2B080U4PSC+RP | 20.0 | 12.5 | 8.5 | 22,000 | 214639440 |
Yearly running cost in 10 large cities
- Phoenix, AZ$995/yr
- Miami, FL$791/yr
- Houston, TX$892/yr
- Atlanta, GA$931/yr
- Los Angeles, CA$912/yr
- New York, NY$2,259/yr
- Chicago, IL$1,840/yr
- Denver, CO$1,535/yr
- Seattle, WA$948/yr
- Minneapolis, MN$1,902/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the American Standard 4A6V0X36A1?
- The American Standard 4A6V0X36A1 is rated at up to 20.5 SEER2 and 12.7 EER2 for cooling and up to 8.7 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 212 certified matchups SEER2 ranges from 17.5-20.5.
- Is the American Standard 4A6V0X36A1 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 22,400 BTU/h at 5°F with a COP of 1.92, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
- How much does the American Standard 4A6V0X36A1 cost to run per year?
- At its rated efficiency it costs about $791-$2,259 a year in electricity in large U.S. cities, depending on climate and local rates - for example $995 in Phoenix and $1,902 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the American Standard 4A6V0X36A1?
- ENERGY STAR lists 212 certified combinations for this outdoor unit. The highest-rated ones use 4PX*CU48BS3, TEM8A0C42V41+TDR, TEM8A0C36V31+TDR.
- What refrigerant does the American Standard 4A6V0X36A1 use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3 ton models
- GE NS22H36MA4-**A20.5 SEER2 · 9.0 HSPF2
- Trane 4TWV0X36A1 · cold climate20.5 SEER2 · 8.7 HSPF2
- Lennox SL22KLV-036-230A · cold climate20.5 SEER2 · 10.5 HSPF2
- Electric Air EA-RW36DCU · cold climate20.2 SEER2 · 10.2 HSPF2
- Sure SP19AY36AJVC · cold climate21.0 SEER2 · 10.0 HSPF2
- SAMYOU VUH36-VA6BA(O) · cold climate20.2 SEER2 · 10.2 HSPF2
- Ruud UP19AY36AJVC · cold climate21.0 SEER2 · 10.0 HSPF2
- Armstrong Air A7CP21V36P-**A · cold climate20.0 SEER2 · 10.4 HSPF2
See all 302 3 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 24, 2025. How we use the data.