HVAC Rated

3-ton central heat pump · NS22H SERIES

GE NS22H36MA4-**A

Excellent cooling efficiency and average heating efficiency for a 3-ton central heat pump, but not rated for cold climates.

Ranks #18 of 302 3 ton central heat pumps for cooling efficiency, and costs about $961 a year to run in a mixed climate like Atlanta.

SEER2
20.5 Cooling efficiency over a season
Excellent · beats 96%
HSPF2
9.0 Heating efficiency over a season
Average · beats 54%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
18,600 BTU/h54% of its 47°F output
Very good · beats 88%

A good fit if…

  • You want low cooling bills - its SEER2 beats 96% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 73 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications3 ton, R-410A
General
BrandGE
Outdoor unit modelNS22H36MA4-**A
SeriesNS22H SERIES
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceMarch 13, 2023
Last certifiedMay 27, 2026
Cooling
SEER2Seasonal efficiency, higher is better20.5 (range 17.5-20.5)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity34,000-36,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-9.0
Capacity at 47°F32,800-35,000 BTU/h
Capacity at 17°F21,800-23,000 BTU/h
Capacity at 5°F17,800-18,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.02-2.30
ENERGY STAR cold climateNo
Heating output as it gets colder54% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with NCUC48CT4+TDR at the standard test temperatures, in BTU/h:

Certified matchups73 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 73 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
NCUC48CT4+TDRNF96U110V5C20.512.08.818,200212403899
NCUC48CT4+TDRNF97U090M4C20.512.08.818,400212403901
NCUU48CP4+TDR+TXVNF97U110M5C20.512.08.818,100212403937
NCUU48CP4+TDR+TXVNF97U090M4C20.512.08.818,400212403935
NCUC48CT4+TDRNF97U110M5C20.512.08.818,100212403903
NCUU48CP4+TDR+TXVNF96U110V5C20.512.08.818,200212403933
NAM42V2TA4-20.011.79.018,300212403841
NAM36V2TA4-20.012.09.018,200212403838
NCUC48CT4+TDRNF97X080V4C20.012.08.818,300212403904
NCUC48CT4+TDRNF96U090V5C20.012.08.818,200212403898
NCUU48CP4+TDR+TXVNF97X080V4C20.012.08.818,300212403938
NCUU48CP4+TDR+TXVNF97X080V5C20.012.08.818,400212403939
NCUC48CT4+TDRNF96U090V3C20.012.08.818,300212403897
NCUU48CP4+TDR+TXVNF97U090M3C20.012.08.818,300212403934
NCUC48CT4+TDRNF97U090M5C20.012.08.818,300212403902
NCUU48CP4+TDR+TXVNF96U090V5C20.012.08.818,200212403932
NCUC48CT4+TDRNF97X080V5C20.012.08.818,400212403905
NCUU48CP4+TDR+TXVNF96U090V3C20.012.08.818,300212403931
NCUC48CT4+TDRNF97U090M3C20.012.08.818,300212403900
NCUU48CP4+TDR+TXVNF97U090M5C20.012.08.818,300212403936
NCUC36BT4+TDRNF97U070M3B20.012.08.518,000212403885
NCHC36CT4+TDRNF97U110M5C20.011.78.517,900212403858
NCHC36CT4+TDRNF97X080V5C20.011.78.518,300212403860
NCUC36BT4+TDRNF96U070V3B20.012.08.518,000212403884
NCUU36BP4+TDR+TXVNF97X060V3B20.011.78.518,000212403921
NCUU36BP4+TDR+TXVNF96U070V3B20.012.08.518,000212403918
NCHC36CT4+TDRNF96U110V5C20.011.78.518,000212403854
NCUC36BT4+TDRNF97X060V3B20.011.78.518,000212403887
NCUU36BP4+TDR+TXVNF97X040V3B20.012.08.518,000212403920
NCUU36BP4+TDR+TXVNF97U070M3B20.012.08.518,000212403919
NCUC36BT4+TDRNF97X040V3B20.012.08.518,000212403886
NCHC36CT4+TDRNF96U090V3C20.011.78.518,100212403852
NCUC48BT4+TDRNF97X040V3B19.512.08.818,500212403893
NCUC48BT4+TDRNF97X060V3B19.511.78.818,500212403894
NCUC48BT4+TDRNF96U070V3B19.512.08.818,500212403891
NCUU48BP4+TDR+TXVNF96U070V3B19.512.08.818,500212403925
NCUU48BP4+TDR+TXVNF97U070M3B19.512.08.818,500212403926
NCUU48BP4+TDR+TXVNF97X040V3B19.512.08.818,500212403927
NCUC48BT4+TDRNF97U070M3B19.512.08.818,500212403892
NCUU48BP4+TDR+TXVNF97X060V3B19.511.78.818,500212403928
NCHC42CT4+TDRNF96U110V5C19.512.08.718,100212403865
NCHC42CT4+TDRNF97X080V5C19.511.78.718,300212403871
NCHC42CT4+TDRNF96U090V3C19.511.78.718,200212403863
NCHC42CT4+TDRNF97U090M4C19.511.78.718,200212403867
NCHC42CT4+TDRNF97U110M5C19.512.08.718,000212403869
NCUC30BT4+TDRNF97X040V3B19.511.78.518,000212403878
NCUC36BT4+TDRNF96U045V3B19.511.78.518,100212403883
NCHC36CT4+TDRNF97U090M3C19.511.78.518,000212403855
NCHC30BT4+TDRNF96U070V3B19.511.78.518,600212403846
NCUC30BT4+TDRNF96U070V3B19.511.78.518,000212403876
NCHC30BT4+TDRNF97U070M3B19.511.78.518,600212403847
NCUC30BT4+TDRNF97U070M3B19.511.78.518,000212403877
NCHC36CT4+TDRNF97U090M4C19.511.78.518,300212403856
NCHC36CT4+TDRNF97X080V4C19.511.78.518,200212403859
NCHC36CT4+TDRNF97U090M5C19.511.78.518,200212403857
NCHC36CT4+TDRNF96U090V5C19.511.78.518,100212403853
NCUU30BP4+TDR+TXVNF96U070V3B19.511.78.518,000212403910
NCUU36BP4+TDR+TXVNF96U045V3B19.511.78.518,100212403917
NCUC30BT4+TDRNF97X060V3B19.511.78.518,000212403879
NCUU30BP4+TDR+TXVNF97X040V3B19.511.78.518,000212403912
Yearly running cost in 10 large cities$814-$2,333

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the GE NS22H36MA4-**A?
The GE NS22H36MA4-**A is rated at up to 20.5 SEER2 and 12.0 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 73 certified matchups SEER2 ranges from 17.5-20.5.
Is the GE NS22H36MA4-**A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
How much does the GE NS22H36MA4-**A cost to run per year?
At its rated efficiency it costs about $814-$2,333 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,025 in Phoenix and $1,966 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the GE NS22H36MA4-**A?
ENERGY STAR lists 73 certified combinations for this outdoor unit. The highest-rated ones use NCUC48CT4+TDR, NCUU48CP4+TDR+TXV, NAM42V2TA4.
What refrigerant does the GE NS22H36MA4-**A use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,028/yrYou save $771/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump GE NS22H36MA4-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,028
Current system, per year
$1,799
You save per year
$771
Payback
17.5 years
Net after 10 years
-$5,793

Cooling $608Heating $421Electricity used: 6,428 kWhSaved vs. a minimum-efficiency heat pump: $348

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 27, 2026. How we use the data.