HVAC Rated

3-ton central heat pump · DAVE LENNOX SIGNATURE SL22KLV SERIES

Lennox SL22KLV-036-230A

Excellent cooling and heating efficiency for a 3-ton central heat pump, and certified for cold climates.

Ranks #17 of 302 3 ton central heat pumps for cooling efficiency, and costs about $830 a year to run in a mixed climate like Atlanta.

SEER2
20.5 Cooling efficiency over a season
Excellent · beats 96%
HSPF2
10.5 Heating efficiency over a season
Excellent · beats 96%
EER2
13.6 Cooling efficiency on a 95°F day
Excellent · beats 96%
Heat at 5°F
34,000 BTU/h85% of its 47°F output
Excellent · beats 96%

A good fit if…

  • You want low cooling bills - its SEER2 beats 96% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 34,000 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 96% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandLennox
Outdoor unit modelSL22KLV-036-230A
SeriesDAVE LENNOX SIGNATURE SL22KLV SERIES
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 14, 2024
Last certifiedSeptember 30, 2026
Cooling
SEER2Seasonal efficiency, higher is better20.5 (range 16.5-20.5)
EER2Efficiency at 95°F outdoors11.2-13.6
Cooling capacity33,000-35,600 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.0-10.5
Capacity at 47°F30,000-32,800 BTU/h
Capacity at 17°F26,600-33,800 BTU/h
Capacity at 5°F24,400-34,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.84-2.42
ENERGY STAR cold climateYes
Heating output as it gets colder85% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CK40HT-51/61C-**+TDR at the standard test temperatures, in BTU/h:

Certified matchups80 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 80 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CK40HT-51/61C-**+TDR · cold climateSL280UH090V60C*20.513.68.526,400217476482
CK40HT-51/61C-**+TDR · cold climateSL280UH090XV60C*20.513.68.526,400217476483
CBK48MVT-060-230- · cold climate-20.013.010.533,200216776011
CBK48MVT-042-230- · cold climate-20.012.88.534,000216776067
CK40HT-51/61C-**+TDR · cold climateSL280UH080NV60C*20.013.48.526,600217476481
CK40HT-51/61C-**+TDR · cold climateSL280UH100NV60C*20.013.48.526,600217476484
CK40HT-51/61C-**+TDR · cold climateSL280UH110V60C*20.013.48.526,600217476485
CK40HT-51/61C-**+TDR · cold climateSL280UH110XV60C*20.013.48.526,600217476486
CK40HT-51/61C-**+TDR · cold climateSL297UH080NV48C*20.013.28.526,600217476487
CK40HT-51/61C-**+TDR · cold climateSLP99UH090XV48C*20.013.28.526,600217476489
CK40HT-51/61C-**+TDR · cold climateSLP99UH110XV60C*20.013.48.526,600217476491
CK40HT-51/61C-**+TDR · cold climateEL297UH090XV48C*20.013.28.526,600217476493
CK40HT-51/61C-**+TDR · cold climateEL297UH110XV48C*20.013.48.526,600217476495
CK40HT-51/61C-**+TDR · cold climateEL297UH110XV60C*20.013.48.526,600217476496
CK40[C,U]T-49C-**+TDR · cold climateSL280UH080NV60C*19.513.29.031,200216776068
CK40HT-51/61C-**+TDR · cold climateSL297UH080NV60C*19.513.28.526,800217476488
CK40HT-51/61C-**+TDR · cold climateSLP99UH090XV60C*19.513.48.526,600217476490
CK40HT-51/61C-**+TDR · cold climateSL280UH080NV48B*19.513.28.526,800217476492
CK40HT-51/61C-**+TDR · cold climateEL297UH090XV60C*19.513.48.526,600217476494
CK40HT-42B-**+TDR · cold climateSL280UH080NV48B*19.513.08.231,200216776083
CK40[C,U]T-60C-**+TDR · cold climateSL280UH090V60C*19.012.810.026,400217476507
CK40[C,U]T-60C-**+TDR · cold climateSL280UH090XV60C*19.012.810.026,400217476508
CK40[C,U]T-60C-**+TDR · cold climateEL297UH110XV48C*19.012.69.826,600217476519
CK40[C,U]T-49C-**+TDR · cold climateSL280UH090V60C*19.013.09.031,400216776069
CK40[C,U]T-49C-**+TDR · cold climateSL280UH090XV60C*19.013.09.031,400216776070
CK40[C,U]T-49C-**+TDR · cold climateSL280UH100NV60C*19.013.29.031,200216776071
CK40[C,U]T-49C-**+TDR · cold climateSL297UH080NV48C*19.012.89.031,600216776074
CK40[C,U]T-49C-**+TDR · cold climateSLP99UH090XV48C*19.012.89.031,600216776076
CK40[C,U]T-49C-**+TDR · cold climateSLP99UH090XV60C*19.012.89.031,600216776077
CK40[C,U]T-49C-**+TDR · cold climateEL297UH090XV48C*19.012.89.031,600216776079
CK40[C,U]T-49C-**+TDR · cold climateEL297UH090XV60C*19.012.89.031,600216776080
CK40[C,U]T-49C-**+TDR · cold climateEL297UH110XV48C*19.012.89.031,600216776081
CK40HT-42B-**+TDR · cold climateSLP99UH070XV36B*19.012.48.127,800217476480
CK40[C,U]T-60C-**+TDR · cold climateSL280UH080NV60C*18.512.69.826,600217476506
CK40[C,U]T-60C-**+TDR · cold climateSL280UH100NV60C*18.512.89.826,600217476509
CK40[C,U]T-60C-**+TDR · cold climateSL280UH110V60C*18.512.89.826,600217476510
CK40[C,U]T-60C-**+TDR · cold climateSL280UH110XV60C*18.512.89.826,600217476511
CK40[C,U]T-60C-**+TDR · cold climateSL297UH080NV48C*18.512.69.826,600217476512
CK40[C,U]T-60C-**+TDR · cold climateSLP99UH090XV48C*18.512.69.826,600217476514
CK40[C,U]T-60C-**+TDR · cold climateSLP99UH090XV60C*18.512.69.826,600217476515
CK40[C,U]T-60C-**+TDR · cold climateSLP99UH110XV60C*18.512.89.826,600217476516
CK40[C,U]T-60C-**+TDR · cold climateEL297UH090XV60C*18.512.69.826,600217476518
CK40[C,U]T-60C-**+TDR · cold climateEL297UH090XV48C*18.512.69.826,600217476517
CK40[C,U]T-60C-**+TDR · cold climateEL297UH110XV60C*18.512.89.826,600217476520
CK40[C,U]T-60D-**+TDR · cold climateSL280UH135V60D*18.511.79.424,400217476459
CK40[C,U]T-60D-**+TDR · cold climateSLP99UH135XV60D*18.511.79.424,400217476462
CK40[C,U]T-60D-**+TDR · cold climateEL297UH110XV60C*18.511.79.424,400217476463
CK40[C,U]T-60D-**+TDR · cold climateEL297UH135XV60D*18.511.79.424,400217476464
CK40[C,U]T-49C-**+TDR · cold climateSL280UH110XV60C*18.512.89.031,600216776073
CK40[C,U]T-49C-**+TDR · cold climateSL280UH110V60C*18.512.89.031,600216776072
CK40[C,U]T-49C-**+TDR · cold climateSLP99UH110XV60C*18.512.89.031,600216776078
CK40[C,U]T-49C-**+TDR · cold climateEL297UH110XV60C*18.512.89.031,600216776082
CK40[C,U]T-60D-**+TDR · cold climateSL297UH080NV48C*18.511.59.024,600217476460
CK40CT-49C-**+DF KIT · cold climateSL280DF110V60C*18.511.79.031,600218808449
CK40[C,U]T-49C-**+TDR · cold climateSL297UH080NV60C*18.512.68.527,600216776075
CBK48MVT-048-230- · cold climate-18.512.88.230,400216776066
CK40HT-42B-**+TDR · cold climateSL280UH090V48B*18.512.68.231,400216776084
CK40HT-42B-**+TDR · cold climateSL280UH090XV48B*18.512.68.231,400216776085
CK40[C,U]T-60C-**+TDR · cold climateSL297UH080NV60C*18.012.69.826,800217476513
CK40[C,U]T-60D-**+TDR · cold climateSL297UH080NV60C*18.011.29.024,600217476461
Yearly running cost in 10 large cities$789-$1,938

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Lennox SL22KLV-036-230A?
The Lennox SL22KLV-036-230A is rated at up to 20.5 SEER2 and 13.6 EER2 for cooling and up to 10.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 80 certified matchups SEER2 ranges from 16.5-20.5.
Is the Lennox SL22KLV-036-230A good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 34,000 BTU/h at 5°F with a COP of 2.42, so it is still 2.4 times as efficient as electric resistance heat at that temperature.
How much does the Lennox SL22KLV-036-230A cost to run per year?
At its rated efficiency it costs about $789-$1,938 a year in electricity in large U.S. cities, depending on climate and local rates - for example $958 in Phoenix and $1,598 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Lennox SL22KLV-036-230A?
ENERGY STAR lists 80 certified combinations for this outdoor unit. The highest-rated ones use CK40HT-51/61C-**+TDR, CBK48MVT-060-230-, CBK48MVT-042-230-.
What refrigerant does the Lennox SL22KLV-036-230A use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $936/yrYou save $810/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Lennox SL22KLV-036-230A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$936
Current system, per year
$1,746
You save per year
$810
Payback
16.1 years
Net after 10 years
-$4,901

Cooling $601Heating $335Electricity used: 5,849 kWhSaved vs. a minimum-efficiency heat pump: $395

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 30, 2026. How we use the data.