HVAC Rated

3-ton central heat pump · Elite EL18KSLV Series

Lennox EL18KSLV-036-230A

Very good cooling and heating efficiency for a 3-ton central heat pump, and certified for cold climates.

Ranks #42 of 302 3 ton central heat pumps for cooling efficiency, and costs about $964 a year to run in a mixed climate like Atlanta.

SEER2
19.3 Cooling efficiency over a season
Very good · beats 89%
HSPF2
9.6 Heating efficiency over a season
Very good · beats 76%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
30,800 BTU/h79% of its 47°F output
Below average · beats 27%

A good fit if…

  • You want low cooling bills - its SEER2 beats 89% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 30,800 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 76% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandLennox
Outdoor unit modelEL18KSLV-036-230A
SeriesElite EL18KSLV Series
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceOctober 29, 2024
Last certifiedSeptember 3, 2026
Cooling
SEER2Seasonal efficiency, higher is better19.3 (range 15.2-19.3)
EER2Efficiency at 95°F outdoors10.0-12.0
Cooling capacity32,200-36,200 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1-9.6
Capacity at 47°F34,000-38,500 BTU/h
Capacity at 17°F27,000-29,600 BTU/h
Capacity at 5°F27,600-30,800 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80-1.95
ENERGY STAR cold climateYes
Heating output as it gets colder79% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CK40HT-42B-**+TDR at the standard test temperatures, in BTU/h:

Certified matchups355 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 355 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CK40HT-42B-**+TDR · cold climateEL297UH070XV36B*19.311.79.127,600218672219
CBK48MVT-042-230- · cold climate-19.011.79.429,400216618914
CK40HT-36C-**+TDR · cold climateML196UH090XE36C*18.911.09.028,400217449921
CK40[C,U]T-36C-**+TDR · cold climateML180UH110V60C*18.811.08.528,200218082917
CK40HT-36C-**+TDR · cold climateML193UH090XE36C*18.711.09.028,200217449922
CK40[C,U]T-36B-**+TDR · cold climateEL280UH090E36B*18.711.08.528,200217449852
CK40HT-30A-**+TDR · cold climateEL280UH045E36A*18.611.09.028,400217189835
CK40HT-36B-**+TDR · cold climateEL280UH090E36B*18.611.08.528,400217449902
CK40HT-36C-**+TDR · cold climateML296UH090XV48C*18.611.09.028,200217449930
CK40HT-30B-**+TDR · cold climateEL280UH090E36B*18.611.08.528,400217449877
CK40[C,U]T-36C-**+TDR · cold climateML296UH110XV60C*18.611.08.528,400218082924
CK40[C,U]T-36C-**+TDR · cold climateML196UH090XE36C*18.611.08.528,200218082922
CBK48MVT-036-230- · cold climate-18.511.09.429,400216618913
CBK47UHET-036-230- · cold climate-18.511.09.429,400216705371
CBK45UHET-036-230- · cold climate-18.511.79.030,000216618909
CK40[C,U]T-36A-**+TDR · cold climateEL280UH045E36A*18.511.08.528,600217189812
CK40[C,U]T-30/36C**+TDR · cold climateML196UH090XE36C*18.510.08.528,600217677937
CK40HT-36C-**+TDR · cold climateEL297UH090XV48C*18.411.79.028,200217449926
CK40[C,U]T-36C-**+TDR · cold climateSL280UH090XV60C*18.411.08.528,200218082927
CK40[C,U]T-36C-**+TDR · cold climateSL280UH090V60C*18.411.08.528,200218082926
CK40HT-36C-**+TDR · cold climateEL297UH110XV48C*18.411.09.028,200217449927
CK40[C,U]T-30/36C**+TDR · cold climateML193UH090XE36C*18.410.08.528,400217677938
CK40DT-42B-**+TDR · cold climateML193DF045XE36B*18.311.09.028,200217449943
CK40[C,U]T-30B-**+TDR · cold climateEL280UH090E36B*18.311.08.528,400217449827
CK40[C,U]T-36B-**+TDR · cold climateML180UH070V48B*18.311.78.528,200217449868
CK40[C,U]T-36C-**+TDR · cold climateSL280UH110XV60C*18.311.08.528,400218082930
CK40[C,U]T-36C-**+TDR · cold climateSL280UH110V60C*18.311.08.528,400218082929
CK40[C,U]T-36C-**+TDR · cold climateML193UH090XE36C*18.311.08.528,000218082919
CK40HT-30B-**+TDR · cold climateML180UH070V48B*18.311.08.528,400217449893
CBK45UHVT-042-230- · cold climate-18.211.79.030,000216618912
CK40HT-36C-**+TDR · cold climateSLP99UH090XV36C*18.211.09.028,400217189875
CK40HT-36B-**+TDR · cold climateML180UH070V48B*18.211.08.528,400217449918
CK40[C,U]T-36C-**+TDR · cold climateSLP99UH110XV60C*18.211.08.528,200218082936
CK40[C,U]T-30A-**+TDR · cold climateEL280UH045E36A*18.211.08.528,600217189789
CK40[C,U]T-36C-**+TDR · cold climateSL280UH080NV60C*18.211.08.528,200218082925
CK40[C,U]T-36C-**+TDR · cold climateEL297UH110XV48C*18.211.08.528,200218082914
CBK43UHET-036-DV- · cold climate-18.110.99.630,200218636321
CBK43UHET-030-DV- · cold climate-18.111.09.530,800218636320
CK40HT-30A-**+TDR · cold climateML180UH045E36A*18.111.09.028,200217189837
CK40HT-30A-**+TDR · cold climateML180UH045XE36A*18.111.09.028,200217189838
CK40[C,U]T-36B-**+TDR · cold climateSL280UH090V48B*18.111.78.528,200217189823
CK40[C,U]T-36B-**+TDR · cold climateML180UH070V36B*18.111.08.528,200217449853
CK40[C,U]T-36B-**+TDR · cold climateSL280UH090V36B*18.111.08.528,200217449851
CK40[C,U]T-36B-**+TDR · cold climateSL280UH090XV48B*18.111.78.528,200217449865
CK40[C,U]T-36C-**+TDR · cold climateEL297UH110XV60C*18.111.08.528,200218082915
CK40[C,U]T-36C-**+TDR · cold climateML297UH110XV60C*18.111.08.528,200218730792
CK40HT-30B-**+TDR · cold climateSL280UH090V48B*18.111.78.528,200217189846
CK40HT-36B-**+TDR · cold climateSL280UH090V48B*18.111.08.528,200217189869
CK40[C,U]T-36B-**+TDR · cold climateML180UH070E36B*18.111.08.528,400217189816
CK40[C,U]T-36B-**+TDR · cold climateML180UH070XE36B*18.111.08.528,400217189817
CK40HT-30B-**+TDR · cold climateSL280UH090XV48B*18.111.78.528,200217449890
CK40HT-36B-**+TDR · cold climateSL280UH090XV48B*18.111.08.528,200217449915
CK40[C,U]T-36B-**+TDR · cold climateML193UH030XE36B*18.111.08.528,600217449860
CK40HT-30B-**+TDR · cold climateSL280UH090V36B*18.111.08.528,400217449876
CBK45UHVT-036-230- · cold climate-18.011.79.530,000216581389
CBK48MVT-030-230- · cold climate-18.011.09.529,600217753035
CBK47UHET-042-230- · cold climate-18.012.09.429,000216705372
CBK45UHET-042-230- · cold climate-18.011.79.030,000216618911
CK40HT-36C-**+TDR · cold climateEL297UH090XV36C*18.011.09.028,400216769596
CK40HT-36C-**+TDR · cold climateML297UH090XV36C*18.011.09.028,400218730764
Yearly running cost in 10 large cities$839-$2,323

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Lennox EL18KSLV-036-230A?
The Lennox EL18KSLV-036-230A is rated at up to 19.3 SEER2 and 11.7 EER2 for cooling and up to 9.6 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 355 certified matchups SEER2 ranges from 15.2-19.3.
Is the Lennox EL18KSLV-036-230A good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 30,800 BTU/h at 5°F with a COP of 1.95, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Lennox EL18KSLV-036-230A cost to run per year?
At its rated efficiency it costs about $839-$2,323 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,045 in Phoenix and $1,949 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Lennox EL18KSLV-036-230A?
ENERGY STAR lists 355 certified combinations for this outdoor unit. The highest-rated ones use CK40HT-42B-**+TDR, CBK48MVT-042-230-, CK40HT-36C-**+TDR.
What refrigerant does the Lennox EL18KSLV-036-230A use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,043/yrYou save $751/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Lennox EL18KSLV-036-230A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,043
Current system, per year
$1,793
You save per year
$751
Payback
17.3 years
Net after 10 years
-$5,493

Cooling $627Heating $415Electricity used: 6,517 kWhSaved vs. a minimum-efficiency heat pump: $336

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 3, 2026. How we use the data.