3-ton central heat pump · A7SCP18V Series
Armstrong Air A7SCP18V36P-**A
Very good cooling and heating efficiency for a 3-ton central heat pump, and certified for cold climates.
Ranks #47 of 302 3 ton central heat pumps for cooling efficiency, and costs about $969 a year to run in a mixed climate like Atlanta.
- SEER2
- 19.0 Cooling efficiency over a seasonVery good · beats 85%
- HSPF2
- 9.6 Heating efficiency over a seasonVery good · beats 76%
- EER2
- 11.7 Cooling efficiency on a 95°F dayAverage · beats 43%
- Heat at 5°F
- 30,800 BTU/h82% of its 47°F outputBelow average · beats 27%
A good fit if…
- You want low cooling bills - its SEER2 beats 85% of central heat pumps.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 30,800 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 76% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Armstrong Air |
| Also sold as | AIREASE |
| Outdoor unit model | A7SCP18V36P-**A |
| Series | A7SCP18V Series |
| Type | Central heat pump |
| Nominal size | 3 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | October 25, 2024 |
| Last certified | July 17, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 19.0 (range 15.2-19.0) |
| EER2Efficiency at 95°F outdoors | 10.0-12.0 |
| Cooling capacity | 32,200-36,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.1-9.6 |
| Capacity at 47°F | 34,000-38,500 BTU/h |
| Capacity at 17°F | 27,000-29,600 BTU/h |
| Capacity at 5°F | 28,000-30,800 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80-1.95 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 7AH2AV42PXC- at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 432 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| 7AH2AV42PXC- · cold climate | - | 19.0 | 11.7 | 9.4 | 29,400 | 216619026 |
| 7AH2AV42PXC- · cold climate | - | 19.0 | 11.7 | 9.4 | 29,400 | 216618970 |
| 7EH36CX-**+TDR · cold climate | A93UH1E090C12A* | 18.7 | 11.0 | 9.0 | 28,200 | 217450186 |
| 7EH36CX-**+TDR · cold climate | A93UH1E090C12A* | 18.7 | 11.0 | 9.0 | 28,200 | 217450368 |
| 7E[C,U]36BX-**+TDR · cold climate | A80UH2E090B12* | 18.7 | 11.0 | 8.5 | 28,200 | 217450155 |
| 7E[C,U]36BX-**+TDR · cold climate | A80UH2E090B12* | 18.7 | 11.0 | 8.5 | 28,200 | 217450337 |
| 7EH30AX-**+TDR · cold climate | A80UH2E045A12* | 18.6 | 11.0 | 9.0 | 28,400 | 217188979 |
| 7EH30AX-**+TDR · cold climate | A80UH2E045A12* | 18.6 | 11.0 | 9.0 | 28,400 | 217188729 |
| 7EH36BX-**+TDR · cold climate | A80UH2E090B12* | 18.6 | 11.0 | 8.5 | 28,400 | 217450177 |
| 7EH36BX-**+TDR · cold climate | A80UH2E090B12* | 18.6 | 11.0 | 8.5 | 28,400 | 217450359 |
| 7EH30BX-**+TDR · cold climate | A80UH2E090B12* | 18.6 | 11.0 | 8.5 | 28,400 | 217450348 |
| 7EH30BX-**+TDR · cold climate | A80UH2E090B12* | 18.6 | 11.0 | 8.5 | 28,400 | 217450166 |
| 7AH2AV36PXC- · cold climate | - | 18.5 | 11.0 | 9.4 | 29,400 | 216619025 |
| 7AH2AV36PXC- · cold climate | - | 18.5 | 11.0 | 9.4 | 29,400 | 216618969 |
| 7AH2AE36PX- · cold climate | - | 18.5 | 11.0 | 9.4 | 29,400 | 216705379 |
| 7AH2AE36PX- · cold climate | - | 18.5 | 11.0 | 9.4 | 29,400 | 216705386 |
| 7AH1AE36PX- · cold climate | - | 18.5 | 11.7 | 9.0 | 30,000 | 216619021 |
| 7AH1AE36PX- · cold climate | - | 18.5 | 11.7 | 9.0 | 30,000 | 216618965 |
| 7E[C,U]36AX-**+TDR · cold climate | A80UH2E045A12* | 18.5 | 11.0 | 8.5 | 28,600 | 217188712 |
| 7E[C,U]36AX-**+TDR · cold climate | A80UH2E045A12* | 18.5 | 11.0 | 8.5 | 28,600 | 217188962 |
| 7EH36CX-**+TDR · cold climate | A97US2V090C16S* | 18.4 | 11.7 | 9.0 | 28,200 | 217450189 |
| 7EH36CX-**+TDR · cold climate | A97US2V090C16S* | 18.4 | 11.7 | 9.0 | 28,200 | 217450371 |
| 7E[C,U]36CX-**+TDR · cold climate | A80US2V090C20* | 18.4 | 11.0 | 8.5 | 28,200 | 218082978 |
| 7E[C,U]36CX-**+TDR · cold climate | A80US2V090C20* | 18.4 | 11.0 | 8.5 | 28,200 | 218082977 |
| 7EH36CX-**+TDR · cold climate | A97US2V110C16S* | 18.4 | 11.0 | 9.0 | 28,200 | 217450190 |
| 7EH36CX-**+TDR · cold climate | A97US2V110C16S* | 18.4 | 11.0 | 9.0 | 28,200 | 217450372 |
| 7ED42BX-**+TDR · cold climate | A93DF1E045B12A* | 18.3 | 11.0 | 9.0 | 28,200 | 217450201 |
| 7ED42BX-**+TDR · cold climate | A93DF1E045B12A* | 18.3 | 11.0 | 9.0 | 28,200 | 217450383 |
| 7E[C,U]30BX-**+TDR · cold climate | A80UH2E090B12* | 18.3 | 11.0 | 8.5 | 28,400 | 217450145 |
| 7E[C,U]30BX-**+TDR · cold climate | A80UH2E090B12* | 18.3 | 11.0 | 8.5 | 28,400 | 217450327 |
| 7E[C,U]36CX-**+TDR · cold climate | A80US2V110C20L* | 18.3 | 11.0 | 8.5 | 28,400 | 218082984 |
| 7E[C,U]36CX-**+TDR · cold climate | A80US2V110C20L* | 18.3 | 11.0 | 8.5 | 28,400 | 218082983 |
| 7E[C,U]36CX-**+TDR · cold climate | A80US2V110C20* | 18.3 | 11.0 | 8.5 | 28,400 | 218082982 |
| 7E[C,U]36CX-**+TDR · cold climate | A80US2V110C20* | 18.3 | 11.0 | 8.5 | 28,400 | 218082981 |
| 7E[C,U]36CX-**+TDR · cold climate | A93UH1E090C12A* | 18.3 | 11.0 | 8.5 | 28,000 | 218082970 |
| 7E[C,U]36CX-**+TDR · cold climate | A93UH1E090C12A* | 18.3 | 11.0 | 8.5 | 28,000 | 218082969 |
| 7AH1AV42PX- · cold climate | - | 18.2 | 11.7 | 9.0 | 30,000 | 216619024 |
| 7AH1AV42PX- · cold climate | - | 18.2 | 11.7 | 9.0 | 30,000 | 216618968 |
| 7EH36CX-**+TDR · cold climate | A98USMV090C12S* | 18.2 | 11.0 | 9.0 | 28,400 | 217188758 |
| 7EH36CX-**+TDR · cold climate | A98USMV090C12S* | 18.2 | 11.0 | 9.0 | 28,400 | 217189008 |
| 7E[C,U]36CX-**+TDR · cold climate | A98USMV110C20S* | 18.2 | 11.0 | 8.5 | 28,200 | 218082996 |
| 7E[C,U]36CX-**+TDR · cold climate | A98USMV110C20S* | 18.2 | 11.0 | 8.5 | 28,200 | 218082995 |
| 7E[C,U]30AX-**+TDR · cold climate | A80UH2E045A12* | 18.2 | 11.0 | 8.5 | 28,600 | 217188695 |
| 7E[C,U]30AX-**+TDR · cold climate | A80UH2E045A12* | 18.2 | 11.0 | 8.5 | 28,600 | 217188945 |
| 7E[C,U]36CX-**+TDR · cold climate | A80US2V080C20X* | 18.2 | 11.0 | 8.5 | 28,200 | 218082976 |
| 7E[C,U]36CX-**+TDR · cold climate | A80US2V080C20X* | 18.2 | 11.0 | 8.5 | 28,200 | 218082975 |
| 7E[C,U]36CX-**+TDR · cold climate | A97US2V110C16S* | 18.2 | 11.0 | 8.5 | 28,200 | 218082964 |
| 7E[C,U]36CX-**+TDR · cold climate | A97US2V110C16S* | 18.2 | 11.0 | 8.5 | 28,200 | 218082963 |
| 7AH1RE36DX- · cold climate | - | 18.1 | 10.9 | 9.6 | 30,200 | 218636339 |
| 7AH1RE36DX- · cold climate | - | 18.1 | 10.9 | 9.6 | 30,200 | 218636330 |
| 7AH1RE30DX- · cold climate | - | 18.1 | 11.0 | 9.5 | 30,800 | 218636338 |
| 7AH1RE30DX- · cold climate | - | 18.1 | 11.0 | 9.5 | 30,800 | 218636329 |
| 7EH30AX-**+TDR · cold climate | A80UH1E045A12* | 18.1 | 11.0 | 9.0 | 28,200 | 217188981 |
| 7EH30AX-**+TDR · cold climate | A80UH1E045A12* | 18.1 | 11.0 | 9.0 | 28,200 | 217188731 |
| 7E[C,U]36BX-**+TDR · cold climate | A80US2V090B16* | 18.1 | 11.7 | 8.5 | 28,200 | 217188719 |
| 7E[C,U]36BX-**+TDR · cold climate | A80US2V090B16* | 18.1 | 11.7 | 8.5 | 28,200 | 217188969 |
| 7E[C,U]36BX-**+TDR · cold climate | A80US2V090B16L* | 18.1 | 11.7 | 8.5 | 28,200 | 217450162 |
| 7E[C,U]36BX-**+TDR · cold climate | A80US2V090B16L* | 18.1 | 11.7 | 8.5 | 28,200 | 217450344 |
| 7E[C,U]36BX-**+TDR · cold climate | A80US2V090B12* | 18.1 | 11.0 | 8.5 | 28,200 | 217450336 |
| 7E[C,U]36BX-**+TDR · cold climate | A80US2V090B12* | 18.1 | 11.0 | 8.5 | 28,200 | 217450154 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,057/yr
- Miami, FL$852/yr
- Houston, TX$948/yr
- Atlanta, GA$969/yr
- Los Angeles, CA$946/yr
- New York, NY$2,329/yr
- Chicago, IL$1,894/yr
- Denver, CO$1,576/yr
- Seattle, WA$970/yr
- Minneapolis, MN$1,952/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Armstrong Air A7SCP18V36P-**A?
- The Armstrong Air A7SCP18V36P-**A is rated at up to 19.0 SEER2 and 11.7 EER2 for cooling and up to 9.6 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 432 certified matchups SEER2 ranges from 15.2-19.0.
- Is the Armstrong Air A7SCP18V36P-**A good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 30,800 BTU/h at 5°F with a COP of 1.95, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the Armstrong Air A7SCP18V36P-**A cost to run per year?
- At its rated efficiency it costs about $852-$2,329 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,057 in Phoenix and $1,952 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Armstrong Air A7SCP18V36P-**A?
- ENERGY STAR lists 432 certified combinations for this outdoor unit. The highest-rated ones use 7AH2AV42PXC-, 7EH36CX-**+TDR, 7E[C,U]36BX-**+TDR.
- What refrigerant does the Armstrong Air A7SCP18V36P-**A use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3 ton models
- Trane 5TCV0X48A1 · cold climate19.0 SEER2 · 9.7 HSPF2
- Bosch BOHA-36RTB-M18S · cold climate19.0 SEER2 · 9.5 HSPF2
- York YDC36E2D11 · cold climate19.0 SEER2 · 10.0 HSPF2
- Haier 1U36T3PC*HE · cold climate19.0 SEER2 · 9.5 HSPF2
- Midea MOVA-36HDN10-M20G · cold climate19.0 SEER2 · 10.0 HSPF2
- Luxaire XH936E2C11 · cold climate19.0 SEER2 · 9.5 HSPF2
- Bosch BOVB-36MTB-M19E · cold climate19.0 SEER2 · 10.0 HSPF2
- Midea MDV-V36WMN10T(A) · cold climate19.0 SEER2 · 9.5 HSPF2
See all 302 3 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 17, 2026. How we use the data.