HVAC Rated

3-ton central heat pump · YDC

York YDC36E2D11

Very good cooling and heating efficiency for a 3-ton central heat pump, and certified for cold climates.

Ranks #45 of 302 3 ton central heat pumps for cooling efficiency, and costs about $934 a year to run in a mixed climate like Atlanta.

SEER2
19.0 Cooling efficiency over a season
Very good · beats 85%
HSPF2
10.0 Heating efficiency over a season
Very good · beats 84%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
36,600 BTU/h100% of its 47°F output
Average · beats 58%

A good fit if…

  • You want low cooling bills - its SEER2 beats 85% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 36,600 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandYork
Outdoor unit modelYDC36E2D11
SeriesYDC
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableYes
On the market sinceApril 10, 2026
Last certifiedSeptember 1, 2026
Cooling
SEER2Seasonal efficiency, higher is better19.0 (range 15.2-19.0)
EER2Efficiency at 95°F outdoors10.6-12.0
Cooling capacity32,200-36,400 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.0-10.0
Capacity at 47°F34,800-36,600 BTU/h
Capacity at 17°F34,600-36,600 BTU/h
Capacity at 5°F32,200-36,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80-2.10
ENERGY STAR cold climateYes
Heating output as it gets colder100% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with JDU36F5XX2DS1 at the standard test temperatures, in BTU/h:

Certified matchups7 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
JDU36F5XX2DS1 · cold climate19.012.010.036,600218619070
CDM48D5XXS1 · cold climate16.011.29.032,800218619076
CDM48C5XXS1 · cold climate16.011.29.032,800218619075
CDM48B5XXS1 · cold climate16.011.29.032,800218619074
CDM30C5XXS1 · cold climate15.211.09.032,400218619073
CDM30B5XXS1 · cold climate15.211.09.032,400218619072
CDM30A5XXS1 · cold climate15.210.69.032,200218619071
Yearly running cost in 10 large cities$841-$2,228

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the York YDC36E2D11?
The York YDC36E2D11 is rated at up to 19.0 SEER2 and 12.0 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 7 certified matchups SEER2 ranges from 15.2-19.0.
Is the York YDC36E2D11 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 36,600 BTU/h at 5°F with a COP of 2.10, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
How much does the York YDC36E2D11 cost to run per year?
At its rated efficiency it costs about $841-$2,228 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,034 in Phoenix and $1,860 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the York YDC36E2D11?
ENERGY STAR lists 7 certified combinations for this outdoor unit. The highest-rated ones use JDU36F5XX2DS1, CDM48D5XXS1, CDM48C5XXS1.
What refrigerant does the York YDC36E2D11 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,024/yrYou save $749/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump York YDC36E2D11
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,024
Current system, per year
$1,773
You save per year
$749
Payback
17.4 years
Net after 10 years
-$5,514

Cooling $630Heating $394Electricity used: 6,401 kWhSaved vs. a minimum-efficiency heat pump: $338

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 1, 2026. How we use the data.