HVAC Rated

3-ton central heat pump · Infinity 20 VS Heat Pump

Carrier 27VNA036A*030

Excellent cooling efficiency and very good heating efficiency for a 3-ton central heat pump, and certified for cold climates.

Ranks #37 of 302 3 ton central heat pumps for cooling efficiency, and costs about $961 a year to run in a mixed climate like Atlanta.

SEER2
19.5 Cooling efficiency over a season
Excellent · beats 91%
HSPF2
9.5 Heating efficiency over a season
Very good · beats 70%
EER2
11.5 Cooling efficiency on a 95°F day
Below average · beats 31%
Heat at 5°F
26,000 BTU/h72% of its 47°F output
Average · beats 48%

A good fit if…

  • You want low cooling bills - its SEER2 beats 91% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 26,000 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandCarrier
Also sold asBryant, Tempstar, Kenmore
Outdoor unit model27VNA036A*030
SeriesInfinity 20 VS Heat Pump
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJune 12, 2023
Last certifiedMay 1, 2026
Cooling
SEER2Seasonal efficiency, higher is better19.5 (range 16.0-19.5)
EER2Efficiency at 95°F outdoors9.0-11.5
Cooling capacity32,600-35,400 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-9.5
Capacity at 47°F34,000-36,200 BTU/h
Capacity at 17°F29,400-31,400 BTU/h
Capacity at 5°F24,400-26,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.75-2.04
ENERGY STAR cold climateYes
Heating output as it gets colder72% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FE5BNBD60L*+UI at the standard test temperatures, in BTU/h:

Certified matchups300 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 300 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FE5BNBD60L*+UI · cold climate-19.511.59.524,400215670616
FE5BN(B,X)C48L*+UI · cold climate-19.011.09.024,600215662626
CAA**6124AM*+UI · cold climate59TN6C120C24**2218.510.59.024,800215669732
CAA**6121AM*+UI · cold climate59MN7C100C21**2218.510.59.024,800215669572
CAA**6121AM*+UI · cold climate58TN*B090C17**1618.510.09.024,800215669482
CAA**6124AM*+UI · cold climate59TN7A100C21**2218.510.59.024,800215679683
CAA**6121AM*+UI · cold climate59TN7A100C21**2218.510.59.024,800215679653
CAA**6024AM*+UI · cold climate58TN*B110C21**2018.510.59.024,600215669322
CAA**6024AM*+UI · cold climate59MN7C120C24**2218.510.09.024,800215669392
CAA**6124AM*+UI · cold climate59TN6C100C21**2218.510.59.024,800215669722
CAA**6024AM*+UI · cold climate59TN7A120C24**2218.510.59.024,800215679583
CAA**6024AM*+UI · cold climate58TN*B090C21**2018.510.59.024,600215669312
CAA**6121AM*+UI · cold climate59TN6C100C21**2218.510.59.024,800215669602
CAA**6124AM*+UI · cold climate58TN*B070C21**2018.510.09.024,800215669622
CAA**6124AM*+UI · cold climate58TN*B135C24**2218.510.59.024,600215669652
CAA**6124AM*+UI · cold climate59MN7C100C21**2218.510.59.024,800215669702
CAA**6124AM*+UI · cold climate59CU5B100C21**2218.510.09.024,600215669672
CAA**6121AM*+UI · cold climate58TN*B110C21**2018.510.59.024,800215669492
CAA**6024AM*+UI · cold climate58TN*B135C24**2218.510.59.024,600215669332
CAA**6124AM*+UI · cold climate59TN7A120C24**2218.510.59.024,800215679693
CAA**6121AM*+UI · cold climate58TN*B070C21**2018.510.09.024,800215669472
CAA**6024AM*+UI · cold climate59TN7A100C21**2218.510.59.024,800215679573
CAA**6121AM*+UI · cold climate58CU*A040C17**1218.510.09.024,800215669422
CAA**6124AM*+UI · cold climate58TN*B090C21**2018.510.59.024,600215669632
CAA**6124AM*+UI · cold climate59MN7C120C24**2218.510.59.024,800215669712
CAA**6124AM*+UI · cold climate58TN*B110C21**2018.510.59.024,600215669642
FE5BN(B,X)C36L*+UI · cold climate-18.510.09.025,600215670606
CAA**6024AM*+UI · cold climate59TN6C120C24**2218.510.59.024,800215669412
CAA**4821AM*+UI · cold climate58TN*B110C21**2018.010.09.025,000215669172
CAA**4821AM*+UI · cold climate59TN6C080C17**1418.09.59.025,200215669272
CAA**6121AM*+UI · cold climate59MN7C060C17**1418.010.09.025,200215669532
CAA**6124AM*+UI · cold climate58CU*A100C21**2018.010.09.024,800215669612
CAA**4821AM*+UI · cold climate58CU*B040C17**1218.010.09.025,000215679493
CAA**6024AM*+UI · cold climate59CU5B100C21**2218.010.09.024,600215669352
CAA**6024AM*+UI · cold climate59TN6C080C21**2018.010.09.024,800215679553
CAA**6124AM*+UI · cold climate59CU5B080C21**2018.010.09.024,800215669662
CAA**4321AM*+UI · cold climate58CU*B060C17**1618.010.09.025,000215679433
CAA**4221AM*+UI · cold climate58TN*B090C21**2018.010.09.025,600215683945
CAA**6121AM*+UI · cold climate58CU*B060C17**1618.010.09.024,800215679613
CAA**4321AM*+UI · cold climate58TN*B070C21**2018.010.09.025,200215683981
CAA**6024AM*+UI · cold climate59CU5B080C21**2018.010.09.024,800215669342
CAA**6121AM*+UI · cold climate59MN7C060C21**2018.010.09.025,000215669542
CAA**6124AM*+UI · cold climate59MN7C060C21**2018.010.09.025,000215669682
CAA**6121AM*+UI · cold climate59TN6C080C21**2018.010.59.024,800215679593
CAA**6121AM*+UI · cold climate59TN7A080C21**2018.010.59.024,800215679643
CAA**6024AM*+UI · cold climate59TN6C100C21**2218.010.59.024,800215669402
CAA**3721AM*+UI · cold climate59TN7A100C21**2218.010.09.025,000215679333
CAA**6124AM*+UI · cold climate59TN6C080C21**2018.010.59.024,800215679663
CAA**4821AM*+UI · cold climate58TN*B070C21**2018.010.09.025,000215669142
CAA**4821AM*+UI · cold climate59CU5B100C21**2218.010.09.025,000215669202
CAA**6121AM*+UI · cold climate58CU*A100C21**2018.010.09.024,800215669442
CAA**6024AM*+UI · cold climate58CU*A100C21**2018.010.09.024,800215669292
CAA**4321AM*+UI · cold climate58CU*B040C17**1218.010.09.025,000215679423
CAA**3721AM*+UI · cold climate59TN6C080C17**1418.010.09.025,200215683927
CAA**4821AM*+UI · cold climate58TN*B070C17**1618.010.09.025,200215669132
CAA**3721AM*+UI · cold climate58TN*B110C21**2018.010.09.025,000215683907
CAA**4321AM*+UI · cold climate59TN6C080C21**2018.010.09.025,200215679413
CAA**4821AM*+UI · cold climate58CU*B060C17**1618.09.59.025,000215679503
CAA**4321AM*+UI · cold climate59MN7C100C21**2218.010.09.025,000215684001
CAA**3721AM*+UI · cold climate59TN6C080C21**2018.010.09.025,200215679273
Same unit, other model numbers3

These model numbers have exactly the same certified ratings and matchups as the Carrier 27VNA036A*030: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$826-$2,325

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Carrier 27VNA036A*030?
The Carrier 27VNA036A*030 is rated at up to 19.5 SEER2 and 11.5 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 300 certified matchups SEER2 ranges from 16.0-19.5.
Is the Carrier 27VNA036A*030 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 26,000 BTU/h at 5°F with a COP of 2.04, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Carrier 27VNA036A*030 cost to run per year?
At its rated efficiency it costs about $826-$2,325 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,034 in Phoenix and $1,955 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Carrier 27VNA036A*030 the same as the Bryant 290VAN036**AA?
Yes, as far as the certified ratings go. ENERGY STAR lists 4 model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Carrier 27VNA036A*030?
ENERGY STAR lists 300 certified combinations for this outdoor unit. The highest-rated ones use FE5BNBD60L*+UI, FE5BN(B,X)C48L*+UI, CAA**6124AM*+UI.
What refrigerant does the Carrier 27VNA036A*030 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,035/yrYou save $748/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Carrier 27VNA036A*030
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,035
Current system, per year
$1,783
You save per year
$748
Payback
17.4 years
Net after 10 years
-$5,516

Cooling $617Heating $417Electricity used: 6,467 kWhSaved vs. a minimum-efficiency heat pump: $336

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 1, 2026. How we use the data.