HVAC Rated

3.5-ton central heat pump · Bronze 15

American Standard N5HP5042A1

Below average cooling and heating efficiency for a 3.5-ton central heat pump, but not rated for cold climates.

Ranks #68 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,261 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
19,900 BTU/h50% of its 47°F output
Very good · beats 85%

A good fit if…

  • You want a choice of indoor units - 144 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications3.5 ton, R-454B
General
BrandAmerican Standard
Also sold asTrane
Outdoor unit modelN5HP5042A1
SeriesBronze 15
TypeCentral heat pump
Nominal size3.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceMay 26, 2026
Last certifiedJune 29, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity38,000-41,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.1
Capacity at 47°F37,600-39,000 BTU/h
Capacity at 17°F25,200-26,200 BTU/h
Capacity at 5°F19,100-19,900 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.11-2.28
ENERGY STAR cold climateNo
Heating output as it gets colder50% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 5TXCD008AS3+TSTAT at the standard test temperatures, in BTU/h:

Certified matchups144 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 144 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
5TXCD008AS3+TSTATA951X120DU5SA16.012.08.119,400218470734
A5AHV006A1D3+TDR+TSTAT-16.012.08.119,400218470505
5TXCD010AS3+TSTATA801X120DM5SD16.012.08.119,400218470496
5TXCD010AS3+TSTATA952V120DU5SB16.012.08.119,200218470494
5TXCD010AS3+TSTATA951X120DU5SA16.012.08.119,300218470493
5TXCD010AS3+TSTAT+P0V0D000M50SD-16.012.08.119,200218470492
5TXCD008AS3+TSTAT+P0V0D000M50SD-16.012.08.119,300218470491
5TXCD008AS3+TSTATA801X120DM5SD16.012.08.119,500218470490
5TXCD008AS3+TSTATA952V120DU5SB16.012.08.119,300218470489
5TXCC009AS3+TSTAT+P0V0C000M50SD-16.012.08.119,200218470482
5TXCC009AS3+TSTATL8V1C100U5VSB16.012.08.119,300218470481
5TXCC007AS3+TSTATA951X100CU5SA16.012.08.119,400218470478
5TXCC007AS3+TSTATA952V080CU5SB16.012.08.119,500218470476
5TXCC007AS3+TSTATA801X080CM5SD16.012.08.119,700218470475
5TXCC007AS3+TSTATA801X100CM5SD16.012.08.119,500218470474
5TXCB006AS3+TSTAT+P0V0B000M40SD-16.012.08.119,300218470469
5PX*DD10AS3+TSTAT+P0V0D000M50SD-16.012.08.119,200218470466
5PX*DD10AS3+TSTATA801X120DM5SD16.012.08.119,400218470465
5PX*DD10AS3+TSTATA952V120DD5SB16.012.08.119,100218470463
5PX*D010AS3+TSTAT+P0V0D000M50SD-16.012.08.119,200218470460
5PX*D010AS3+TSTATA952V120DU5SB16.012.08.119,200218470459
5PX*D010AS3+TSTATA951X120DU5SA16.012.08.119,300218470458
5PX*D010AS3+TSTATA801X120DM5SD16.012.08.119,400218470457
5PX*D008AS3+TSTATA801X120DM5SD16.012.08.119,500218470456
5PX*D008AS3+TSTATA951X120DU5SA16.012.08.119,400218470455
5PX*D008AS3+TSTATA952V120DU5SB16.012.08.119,300218470454
5PX*D008AS3+TSTAT+P0V0D000M50SD-16.012.08.119,300218470453
5PX*CD09AS3+TSTAT+P0V0C000M50SD-16.012.08.119,300218470452
5PX*CD09AS3+TSTATA801X080CM5SD16.012.08.119,600218470451
5PX*CD09AS3+TSTATA801X100CM5SD16.012.08.119,700218470450
5PX*CD09AS3+TSTATA952V100CD5SB16.012.08.119,300218470448
5PX*C009AS3+TSTAT+P0V0C000M50SD-16.012.08.119,200218470444
5PX*C009AS3+TSTATL8V1C100U5VSB16.012.08.119,300218470443
5PX*C009AS3+TSTATA952V100CU5SB16.012.08.119,300218470442
5PX*C009AS3+TSTATA952V080CU5SB16.012.08.119,400218470441
5PX*C009AS3+TSTATA951X100CU5SA16.012.08.119,500218470440
5PX*C009AS3+TSTATA951X080CU5SA16.012.08.119,200218470439
5PX*C009AS3+TSTATA801X100CM5SD16.012.08.119,700218470438
5PX*C009AS3+TSTATA801X080CM5SD16.012.08.119,600218470437
5PX*C007AS3+TSTATA801X100CM5SD16.012.08.119,500218470435
5PX*C007AS3+TSTATA801X080CM5SD16.012.08.119,700218470434
5PX*C007AS3+TSTAT+P0V0C000M50SD-16.012.08.119,400218470433
5PX*C007AS3+TSTATA952V080CU5SB16.012.08.119,500218470430
5PX*C007AS3+TSTATA951X100CU5SA16.012.08.119,400218470429
5PX*B006AS3+TSTAT+P0V0B000M40SD-16.012.08.119,300218470421
A5AHV006A1D3+TDR+TSTAT-16.012.08.119,400218469799
5TXCD010AS3+TSTATA801X120DM5SD16.012.08.119,400218469790
5TXCD010AS3+TSTATA952V120DU5SB16.012.08.119,200218469788
5TXCD010AS3+TSTATA951X120DU5SA16.012.08.119,300218469787
5TXCD010AS3+TSTAT+P0V0D000M50SD-16.012.08.119,200218469786
5TXCD008AS3+TSTAT+P0V0D000M50SD-16.012.08.119,300218469785
5TXCD008AS3+TSTATA801X120DM5SD16.012.08.119,500218469784
5TXCD008AS3+TSTATA951X120DU5SA16.012.08.119,400218469783
5TXCD008AS3+TSTATA952V120DU5SB16.012.08.119,300218469782
5TXCC009AS3+TSTAT+P0V0C000M50SD-16.012.08.119,200218469775
5TXCC009AS3+TSTATL8V1C100U5VSB16.012.08.119,300218469774
5TXCC007AS3+TSTATA951X100CU5SA16.012.08.119,400218469771
5TXCC007AS3+TSTATA952V080CU5SB16.012.08.119,500218469769
5TXCC007AS3+TSTATA801X080CM5SD16.012.08.119,700218469768
5TXCC007AS3+TSTATA801X100CM5SD16.012.08.119,500218469767
Yearly running cost in 10 large cities$1,158-$2,990

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the American Standard N5HP5042A1?
The American Standard N5HP5042A1 is rated at up to 16.0 SEER2 and 12.0 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 144 certified matchups SEER2 ranges from 15.2-16.0.
Is the American Standard N5HP5042A1 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3.5-ton model.
How much does the American Standard N5HP5042A1 cost to run per year?
At its rated efficiency it costs about $1,158-$2,990 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,413 in Phoenix and $2,487 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the American Standard N5HP5042A1?
ENERGY STAR lists 144 certified combinations for this outdoor unit. The highest-rated ones use 5TXCD008AS3+TSTAT, A5AHV006A1D3+TDR+TSTAT, 5TXCD010AS3+TSTAT.
What refrigerant does the American Standard N5HP5042A1 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,394/yrYou save $618/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump American Standard N5HP5042A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,394
Current system, per year
$2,012
You save per year
$618
Payback
24.3 years
Net after 10 years
-$8,823

Cooling $869Heating $525Electricity used: 8,715 kWhSaved vs. a minimum-efficiency heat pump: $145

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3.5 ton models

See all 138 3.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 29, 2026. How we use the data.