3.5-ton central heat pump · LX SERIES
Guardian RHP15042B21
Below average cooling and heating efficiency for a 3.5-ton central heat pump, but not rated for cold climates.
Ranks #75 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,304 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.0 Cooling efficiency over a seasonBelow average · beats 26%
- HSPF2
- 8.1 Heating efficiency over a seasonBelow average · beats 20%
- EER2
- 11.7 Cooling efficiency on a 95°F dayAverage · beats 43%
- Heat at 5°F
- 22,400 BTU/h55% of its 47°F outputExcellent · beats 94%
A good fit if…
- You want a choice of indoor units - 54 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Guardian |
| Also sold as | EVCON |
| Outdoor unit model | RHP15042B21 |
| Series | LX SERIES |
| Type | Central heat pump |
| Nominal size | 3.5 ton |
| CompressorVariable-speed units run longer at low power | Two-stage |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | May 18, 2023 |
| Last certified | July 7, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.0 (range 15.2-16.0) |
| EER2Efficiency at 95°F outdoors | 11.7-12.0 |
| Cooling capacity | 39,500-41,500 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.1 |
| Capacity at 47°F | 38,000-40,500 BTU/h |
| Capacity at 17°F | 24,600-26,600 BTU/h |
| Capacity at 5°F | 18,600-22,400 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00-2.38 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with XAHC48FBCN1 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| XAHC48FBCN1 | RG19100C20MPS1 | 16.0 | 11.7 | 8.1 | 22,200 | 212415615 |
| XAHC48FBCN1 | RG19100C20MPS1 | 16.0 | 11.7 | 8.1 | 22,200 | 212415616 |
| XAHC48FBCN1 | RG19080C20MPS1 | 16.0 | 11.7 | 8.1 | 22,400 | 212415742 |
| XAHC48FBCN1 | RG19080C20MPS1 | 16.0 | 11.7 | 8.1 | 22,400 | 212415741 |
| XAHC48FBCN1 | RGF1L080BE12MP12 | 16.0 | 11.7 | 8.1 | 18,600 | 210347064 |
| XAHC48FBCN1 | RGF1L080BE12MP12 | 16.0 | 11.7 | 8.1 | 18,600 | 210347065 |
| XAHC48FXXN1+JMET16CS2N1+TXV | - | 16.0 | 12.0 | 8.1 | 21,000 | 210347135 |
| XAHC48FXXN1+JMET16CS2N1+TXV | - | 16.0 | 12.0 | 8.1 | 21,000 | 210347134 |
| XAHC48FBCN1+JMET16CS2N1 | - | 16.0 | 12.0 | 8.1 | 21,000 | 210347141 |
| XAHC48FBCN1+JMET16CS2N1 | - | 16.0 | 12.0 | 8.1 | 21,000 | 210347140 |
| XAFD48FBCN1 | RG19120D20MPS1 | 15.2 | 12.0 | 8.1 | 20,800 | 212415587 |
| XAFD48FBCN1 | RG19120D20MPS1 | 15.2 | 12.0 | 8.1 | 20,800 | 212415588 |
| XAHD48FXXN1+TXV | TM9Y100C20MP11 | 15.2 | 11.7 | 8.1 | 20,200 | 210347671 |
| XAHD48FXXN1+TXV | TM9Y100C20MP11 | 15.2 | 11.7 | 8.1 | 20,200 | 210347672 |
| XAHD48FBCN1 | TM9Y100C20MP11 | 15.2 | 11.7 | 8.1 | 20,200 | 210347678 |
| XAHD48FBCN1 | TM9Y100C20MP11 | 15.2 | 11.7 | 8.1 | 20,200 | 210347677 |
| XAHC48FBCN1+JME16C2SN1 | - | 15.2 | 12.0 | 8.1 | 22,000 | 214799743 |
| XAHC48FBCN1+JME16C2SN1 | - | 15.2 | 12.0 | 8.1 | 22,000 | 214799744 |
| XAHD48FBCN1+JME18D2SN1 | - | 15.2 | 12.0 | 8.1 | 22,000 | 214799767 |
| XAHD48FBCN1+JME18D2SN1 | - | 15.2 | 12.0 | 8.1 | 22,000 | 214799768 |
| XAFD60GBCN1+JME18D2SN1 | - | 15.2 | 12.0 | 8.1 | 21,200 | 214799803 |
| XAFD60GBCN1+JME18D2SN1 | - | 15.2 | 12.0 | 8.1 | 21,200 | 214799804 |
| XAHC60GBCN1+JME12C2SN1 | - | 15.2 | 12.0 | 8.1 | 21,200 | 214799810 |
| XAHC60GBCN1+JME12C2SN1 | - | 15.2 | 12.0 | 8.1 | 21,200 | 214799811 |
| XAHC60GBCN1+JME16C2SN1 | - | 15.2 | 12.0 | 8.1 | 21,600 | 214799832 |
| XAHC60GBCN1+JME16C2SN1 | - | 15.2 | 12.0 | 8.1 | 21,600 | 214799833 |
| XAHD60GBCN1+JME18D2SN1 | - | 15.2 | 12.0 | 8.1 | 21,600 | 214799839 |
| XAHD60GBCN1+JME18D2SN1 | - | 15.2 | 12.0 | 8.1 | 21,600 | 214799840 |
| XAHC48FBCN1 | RG19100C16MPS1 | 15.2 | 11.7 | 7.8 | 22,200 | 212415679 |
| XAHC48FBCN1 | RG19100C16MPS1 | 15.2 | 11.7 | 7.8 | 22,200 | 212415678 |
| XAFC48FXXN1+TXV | TM9Y080C16MP11 | 15.2 | 11.7 | 7.8 | 19,600 | 210347683 |
| XAFC48FXXN1+TXV | TM9Y080C16MP11 | 15.2 | 11.7 | 7.8 | 19,600 | 210347684 |
| XAFC48FBCN1 | TM9Y080C16MP11 | 15.2 | 11.7 | 7.8 | 19,600 | 210347689 |
| XAHC48FXXN1+TXV | TM9Y060B12MP11 | 15.2 | 11.7 | 7.8 | 19,200 | 210347701 |
| XAHC48FXXN1+TXV | TM9Y060B12MP11 | 15.2 | 11.7 | 7.8 | 19,200 | 210347702 |
| XAHC48FBCN1 | TM9Y060B12MP11 | 15.2 | 11.7 | 7.8 | 19,200 | 210347708 |
| XAHC48FBCN1 | TM9Y060B12MP11 | 15.2 | 11.7 | 7.8 | 19,200 | 210347707 |
| XAFC48FBCN1 | TM9Y080C16MP11 | 15.2 | 11.7 | 7.8 | 19,600 | 210347690 |
| XAFC48FBCN1 | RG19080C20MPS1 | 15.2 | 11.7 | 7.8 | 20,600 | 212415769 |
| XAFC48FBCN1 | RG19080C20MPS1 | 15.2 | 11.7 | 7.8 | 20,600 | 212415770 |
| XAHC48FBCN1+JME12C2SN1 | - | 15.2 | 12.0 | 7.8 | 21,600 | 214799755 |
| XAHC48FBCN1+JME12C2SN1 | - | 15.2 | 12.0 | 7.8 | 21,600 | 214799756 |
| XAFC60GBCN1+JME12C2SN1 | - | 15.2 | 12.0 | 7.8 | 20,600 | 214799779 |
| XAFC60GBCN1+JME12C2SN1 | - | 15.2 | 12.0 | 7.8 | 20,600 | 214799780 |
| XAFC60GBCN1+JME16C2SN1 | - | 15.2 | 11.7 | 7.8 | 21,000 | 214799796 |
| XAFC60GBCN1+JME16C2SN1 | - | 15.2 | 11.7 | 7.8 | 21,000 | 214799797 |
| XAFC48FBCN1+JME12C2SN1 | - | 15.2 | 12.0 | 7.8 | 20,200 | 214799712 |
| XAFC48FBCN1+JME12C2SN1 | - | 15.2 | 12.0 | 7.8 | 20,200 | 214799713 |
| XAFC48FBCN1+JME16C2SN1 | - | 15.2 | 12.0 | 7.8 | 20,200 | 214799719 |
| XAFC48FBCN1+JME16C2SN1 | - | 15.2 | 12.0 | 7.8 | 20,200 | 214799720 |
| XAFD48FBCN1+JME18D2SN1 | - | 15.2 | 12.0 | 7.8 | 20,800 | 214799726 |
| XAFD48FBCN1+JME18D2SN1 | - | 15.2 | 12.0 | 7.8 | 20,800 | 214799727 |
| XAUC48FXXN1+TXV | TM9Y080C16MP11 | 15.2 | 11.7 | 7.8 | 19,600 | 210347695 |
| XAUC48FXXN1+TXV | TM9Y080C16MP11 | 15.2 | 11.7 | 7.8 | 19,600 | 210347696 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,454/yr
- Miami, FL$1,188/yr
- Houston, TX$1,303/yr
- Atlanta, GA$1,304/yr
- Los Angeles, CA$1,266/yr
- New York, NY$3,100/yr
- Chicago, IL$2,513/yr
- Denver, CO$2,087/yr
- Seattle, WA$1,280/yr
- Minneapolis, MN$2,581/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Guardian RHP15042B21?
- The Guardian RHP15042B21 is rated at up to 16.0 SEER2 and 11.7 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 54 certified matchups SEER2 ranges from 15.2-16.0.
- Is the Guardian RHP15042B21 good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3.5-ton model.
- How much does the Guardian RHP15042B21 cost to run per year?
- At its rated efficiency it costs about $1,188-$3,100 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,454 in Phoenix and $2,581 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Guardian RHP15042B21?
- ENERGY STAR lists 54 certified combinations for this outdoor unit. The highest-rated ones use XAHC48FBCN1, XAHC48FXXN1+JMET16CS2N1+TXV, XAHC48FBCN1+JMET16CS2N1.
- What refrigerant does the Guardian RHP15042B21 use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3.5 ton models
- Fujitsu FOP1542TJAYNA · cold climate16.0 SEER2 · 8.1 HSPF2
- Luxaire THF2B42T2116.0 SEER2 · 8.1 HSPF2
- Friedrich FWP15AY42AJ2N · cold climate16.0 SEER2 · 8.1 HSPF2
- Mainline MLP15AY42AJ2N · cold climate16.0 SEER2 · 8.1 HSPF2
- Friedrich FRP15AY42AJ2N · cold climate16.0 SEER2 · 8.1 HSPF2
- Mainline MPP15AY42AJ2N · cold climate16.0 SEER2 · 8.1 HSPF2
- DuraSTAR DRHP15B42AJ2AN · cold climate16.0 SEER2 · 8.1 HSPF2
- RunTru A5HP5042A116.0 SEER2 · 8.1 HSPF2
See all 138 3.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 7, 2026. How we use the data.