HVAC Rated

3.5-ton central heat pump · A5HP5

RunTru A5HP5042A1

Below average cooling and heating efficiency for a 3.5-ton central heat pump, but not rated for cold climates.

Ranks #79 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,298 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
20,000 BTU/h49% of its 47°F output
Very good · beats 88%

A good fit if…

  • You want a choice of indoor units - 250 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications3.5 ton, R-454B
General
BrandRunTru
Also sold asAmeristar
Outdoor unit modelA5HP5042A1
SeriesA5HP5
TypeCentral heat pump
Nominal size3.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceFebruary 19, 2024
Last certifiedMay 7, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity37,800-41,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.1
Capacity at 47°F37,400-40,500 BTU/h
Capacity at 17°F24,800-26,400 BTU/h
Capacity at 5°F18,800-20,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.30
ENERGY STAR cold climateNo
Heating output as it gets colder49% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 5TXCC007AS3+TSTAT at the standard test temperatures, in BTU/h:

Certified matchups250 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 250 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
5TXCC007AS3+TSTATL8V1C100U5VSB16.012.08.119,500214296566
5TXCC007AS3+TSTATA952V100CU5SB16.012.08.119,700214296568
5TXCC007AS3+TSTATL8V1C100U5VSB16.012.08.119,500214296567
5TXCC007AS3+TSTATA952V100CU5SB16.012.08.119,700214296569
5TXCC007AS3+TSTATA952V100CU5SA16.011.78.119,700214296570
5TXCC007AS3+TSTATA952V100CU5SA16.011.78.119,700214296571
5TXCC007AS3+TSTATA952V080CU5SB16.012.08.119,700214296572
5TXCC007AS3+TSTATA952V080CU5SB16.012.08.119,700214296573
5TXCC007AS3+TSTATA952V080CU5SA16.012.08.119,200214296575
5TXCC007AS3+TSTATA952V080CU5SA16.012.08.119,200214296574
5TXCD010AS3+TSTATA952V120DU5SA16.012.08.118,900214296595
5TXCD010AS3+TSTATA952V120DU5SB16.012.08.119,400214296596
5TXCD010AS3+TSTATA952V120DU5SA16.012.08.118,900214296594
5TXCD010AS3+TSTATA952V120DU5SB16.012.08.119,400214296597
A5AHV004A1D3+TDR+TSTAT-16.012.08.119,100214296606
A5AHV004A1D3+TDR+TSTAT-16.012.08.119,100214296607
A5AHV006A1D3+TDR+TSTAT-16.012.08.119,400214296609
A5AHV006A1D3+TDR+TSTAT-16.012.08.119,400214296608
A5AHV007A1D3+TDR+TSTAT-16.012.08.119,400214296611
A5AHV007A1D3+TDR+TSTAT-16.012.08.119,400214296610
A5AHV005A1D3+TDR+TSTAT-16.012.08.119,100215611106
A5AHV005A1D3+TDR+TSTAT-16.012.08.119,100215611107
5TXCC009AS3+TSTATA801X080CM5TD16.012.08.119,200215575503
5TXCC009AS3+TSTATA951X100CU5SA16.012.08.119,500215575504
5TXCC009AS3+TSTATA951X100CU5SA16.012.08.119,500215575505
5TXCC009AS3+TSTATA952V100CU5SB16.012.08.119,200215575506
5TXCC009AS3+TSTATA952V100CU5SB16.012.08.119,200215575507
5TXCC009AS3+TSTATL8V1C100U5VSB16.012.08.119,100215575508
5TXCC009AS3+TSTATL8V1C100U5VSB16.012.08.119,100215575509
5TXCD008AS3+TSTAT+P0V0D000M50SD-16.012.08.119,200215575516
5TXCD008AS3+TSTAT+P0V0D000M50SD-16.012.08.119,200215575517
5TXCD008AS3+TSTATA952V120DU5SB16.012.08.119,500215575518
5TXCD008AS3+TSTATA952V120DU5SB16.012.08.119,500215575519
5TXCD008AS3+TSTATA951X120DU5SA16.012.08.119,300215575520
5TXCD008AS3+TSTATA951X120DU5SA16.012.08.119,300215575521
5TXCD008AS3+TSTATA801X120DM5TD16.012.08.119,600215575522
5TXCD008AS3+TSTATA801X120DM5TD16.012.08.119,600215575523
5TXCD008AS3+TSTATA801X120DM5SD16.012.08.119,600215575524
5TXCD008AS3+TSTATA801X120DM5SD16.012.08.119,600215575525
5PX*C007AS3+TSTATA801X080CM5TD16.012.08.119,300215575330
5PX*C007AS3+TSTATA801X080CM5TD16.012.08.119,300215575331
5PX*C007AS3+TSTATA801X100CM5SD16.012.08.119,400215575332
5PX*C007AS3+TSTATA801X100CM5SD16.012.08.119,400215575333
5PX*C007AS3+TSTAT+P0V0C000M50SD-16.012.08.119,400215575334
5PX*C007AS3+TSTAT+P0V0C000M50SD-16.012.08.119,400215575335
5PX*C007AS3+TSTATL8V1C100U5VSB16.012.08.119,600215575340
5PX*C007AS3+TSTATL8V1C100U5VSB16.012.08.119,600215575341
5PX*C007AS3+TSTATA952V080CU5SB16.012.08.119,400215575344
5PX*C007AS3+TSTATA801X100CM5TD16.012.08.119,400215575346
5PX*C007AS3+TSTATA952V080CU5SB16.012.08.119,400215575345
5PX*C007AS3+TSTATA801X100CM5TD16.012.08.119,400215575347
5PX*C007AS3+TSTATA801X080CM5SD16.012.08.119,300215575348
5PX*C007AS3+TSTATA801X080CM5SD16.012.08.119,300215575349
5PX*C007AS3+TSTATA952V100CU5SB16.012.08.119,200215575350
5PX*C007AS3+TSTATA952V100CU5SB16.012.08.119,200215575351
5PX*C009AS3+TSTATA801X080CM5SD16.012.08.119,200215575352
5PX*C009AS3+TSTATA801X080CM5SD16.012.08.119,200215575353
5PX*C009AS3+TSTATA801X080CM5TD16.012.08.119,200215575354
5PX*C009AS3+TSTATA801X080CM5TD16.012.08.119,200215575355
5PX*C009AS3+TSTATA801X100CM5SD16.012.08.119,600215575356
Yearly running cost in 10 large cities$1,174-$3,092

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the RunTru A5HP5042A1?
The RunTru A5HP5042A1 is rated at up to 16.0 SEER2 and 12.0 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 250 certified matchups SEER2 ranges from 15.2-16.0.
Is the RunTru A5HP5042A1 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3.5-ton model.
How much does the RunTru A5HP5042A1 cost to run per year?
At its rated efficiency it costs about $1,174-$3,092 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,441 in Phoenix and $2,578 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the RunTru A5HP5042A1?
ENERGY STAR lists 250 certified combinations for this outdoor unit. The highest-rated ones use 5TXCC007AS3+TSTAT, 5TXCD010AS3+TSTAT, A5AHV004A1D3+TDR+TSTAT.
What refrigerant does the RunTru A5HP5042A1 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,426/yrYou save $628/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump RunTru A5HP5042A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,426
Current system, per year
$2,054
You save per year
$628
Payback
23.9 years
Net after 10 years
-$8,719

Cooling $880Heating $546Electricity used: 8,914 kWhSaved vs. a minimum-efficiency heat pump: $148

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3.5 ton models

See all 138 3.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 7, 2026. How we use the data.