3.5-ton central heat pump · A5HP5
RunTru A5HP5042A1
Below average cooling and heating efficiency for a 3.5-ton central heat pump, but not rated for cold climates.
Ranks #79 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,298 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.0 Cooling efficiency over a seasonBelow average · beats 26%
- HSPF2
- 8.1 Heating efficiency over a seasonBelow average · beats 20%
- EER2
- 12.0 Cooling efficiency on a 95°F dayAverage · beats 64%
- Heat at 5°F
- 20,000 BTU/h49% of its 47°F outputVery good · beats 88%
A good fit if…
- You want a choice of indoor units - 250 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | RunTru |
| Also sold as | Ameristar |
| Outdoor unit model | A5HP5042A1 |
| Series | A5HP5 |
| Type | Central heat pump |
| Nominal size | 3.5 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | February 19, 2024 |
| Last certified | May 7, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.0 (range 15.2-16.0) |
| EER2Efficiency at 95°F outdoors | 11.7-12.0 |
| Cooling capacity | 37,800-41,500 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.1 |
| Capacity at 47°F | 37,400-40,500 BTU/h |
| Capacity at 17°F | 24,800-26,400 BTU/h |
| Capacity at 5°F | 18,800-20,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00-2.30 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 5TXCC007AS3+TSTAT at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 250 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| 5TXCC007AS3+TSTAT | L8V1C100U5VSB | 16.0 | 12.0 | 8.1 | 19,500 | 214296566 |
| 5TXCC007AS3+TSTAT | A952V100CU5SB | 16.0 | 12.0 | 8.1 | 19,700 | 214296568 |
| 5TXCC007AS3+TSTAT | L8V1C100U5VSB | 16.0 | 12.0 | 8.1 | 19,500 | 214296567 |
| 5TXCC007AS3+TSTAT | A952V100CU5SB | 16.0 | 12.0 | 8.1 | 19,700 | 214296569 |
| 5TXCC007AS3+TSTAT | A952V100CU5SA | 16.0 | 11.7 | 8.1 | 19,700 | 214296570 |
| 5TXCC007AS3+TSTAT | A952V100CU5SA | 16.0 | 11.7 | 8.1 | 19,700 | 214296571 |
| 5TXCC007AS3+TSTAT | A952V080CU5SB | 16.0 | 12.0 | 8.1 | 19,700 | 214296572 |
| 5TXCC007AS3+TSTAT | A952V080CU5SB | 16.0 | 12.0 | 8.1 | 19,700 | 214296573 |
| 5TXCC007AS3+TSTAT | A952V080CU5SA | 16.0 | 12.0 | 8.1 | 19,200 | 214296575 |
| 5TXCC007AS3+TSTAT | A952V080CU5SA | 16.0 | 12.0 | 8.1 | 19,200 | 214296574 |
| 5TXCD010AS3+TSTAT | A952V120DU5SA | 16.0 | 12.0 | 8.1 | 18,900 | 214296595 |
| 5TXCD010AS3+TSTAT | A952V120DU5SB | 16.0 | 12.0 | 8.1 | 19,400 | 214296596 |
| 5TXCD010AS3+TSTAT | A952V120DU5SA | 16.0 | 12.0 | 8.1 | 18,900 | 214296594 |
| 5TXCD010AS3+TSTAT | A952V120DU5SB | 16.0 | 12.0 | 8.1 | 19,400 | 214296597 |
| A5AHV004A1D3+TDR+TSTAT | - | 16.0 | 12.0 | 8.1 | 19,100 | 214296606 |
| A5AHV004A1D3+TDR+TSTAT | - | 16.0 | 12.0 | 8.1 | 19,100 | 214296607 |
| A5AHV006A1D3+TDR+TSTAT | - | 16.0 | 12.0 | 8.1 | 19,400 | 214296609 |
| A5AHV006A1D3+TDR+TSTAT | - | 16.0 | 12.0 | 8.1 | 19,400 | 214296608 |
| A5AHV007A1D3+TDR+TSTAT | - | 16.0 | 12.0 | 8.1 | 19,400 | 214296611 |
| A5AHV007A1D3+TDR+TSTAT | - | 16.0 | 12.0 | 8.1 | 19,400 | 214296610 |
| A5AHV005A1D3+TDR+TSTAT | - | 16.0 | 12.0 | 8.1 | 19,100 | 215611106 |
| A5AHV005A1D3+TDR+TSTAT | - | 16.0 | 12.0 | 8.1 | 19,100 | 215611107 |
| 5TXCC009AS3+TSTAT | A801X080CM5TD | 16.0 | 12.0 | 8.1 | 19,200 | 215575503 |
| 5TXCC009AS3+TSTAT | A951X100CU5SA | 16.0 | 12.0 | 8.1 | 19,500 | 215575504 |
| 5TXCC009AS3+TSTAT | A951X100CU5SA | 16.0 | 12.0 | 8.1 | 19,500 | 215575505 |
| 5TXCC009AS3+TSTAT | A952V100CU5SB | 16.0 | 12.0 | 8.1 | 19,200 | 215575506 |
| 5TXCC009AS3+TSTAT | A952V100CU5SB | 16.0 | 12.0 | 8.1 | 19,200 | 215575507 |
| 5TXCC009AS3+TSTAT | L8V1C100U5VSB | 16.0 | 12.0 | 8.1 | 19,100 | 215575508 |
| 5TXCC009AS3+TSTAT | L8V1C100U5VSB | 16.0 | 12.0 | 8.1 | 19,100 | 215575509 |
| 5TXCD008AS3+TSTAT+P0V0D000M50SD | - | 16.0 | 12.0 | 8.1 | 19,200 | 215575516 |
| 5TXCD008AS3+TSTAT+P0V0D000M50SD | - | 16.0 | 12.0 | 8.1 | 19,200 | 215575517 |
| 5TXCD008AS3+TSTAT | A952V120DU5SB | 16.0 | 12.0 | 8.1 | 19,500 | 215575518 |
| 5TXCD008AS3+TSTAT | A952V120DU5SB | 16.0 | 12.0 | 8.1 | 19,500 | 215575519 |
| 5TXCD008AS3+TSTAT | A951X120DU5SA | 16.0 | 12.0 | 8.1 | 19,300 | 215575520 |
| 5TXCD008AS3+TSTAT | A951X120DU5SA | 16.0 | 12.0 | 8.1 | 19,300 | 215575521 |
| 5TXCD008AS3+TSTAT | A801X120DM5TD | 16.0 | 12.0 | 8.1 | 19,600 | 215575522 |
| 5TXCD008AS3+TSTAT | A801X120DM5TD | 16.0 | 12.0 | 8.1 | 19,600 | 215575523 |
| 5TXCD008AS3+TSTAT | A801X120DM5SD | 16.0 | 12.0 | 8.1 | 19,600 | 215575524 |
| 5TXCD008AS3+TSTAT | A801X120DM5SD | 16.0 | 12.0 | 8.1 | 19,600 | 215575525 |
| 5PX*C007AS3+TSTAT | A801X080CM5TD | 16.0 | 12.0 | 8.1 | 19,300 | 215575330 |
| 5PX*C007AS3+TSTAT | A801X080CM5TD | 16.0 | 12.0 | 8.1 | 19,300 | 215575331 |
| 5PX*C007AS3+TSTAT | A801X100CM5SD | 16.0 | 12.0 | 8.1 | 19,400 | 215575332 |
| 5PX*C007AS3+TSTAT | A801X100CM5SD | 16.0 | 12.0 | 8.1 | 19,400 | 215575333 |
| 5PX*C007AS3+TSTAT+P0V0C000M50SD | - | 16.0 | 12.0 | 8.1 | 19,400 | 215575334 |
| 5PX*C007AS3+TSTAT+P0V0C000M50SD | - | 16.0 | 12.0 | 8.1 | 19,400 | 215575335 |
| 5PX*C007AS3+TSTAT | L8V1C100U5VSB | 16.0 | 12.0 | 8.1 | 19,600 | 215575340 |
| 5PX*C007AS3+TSTAT | L8V1C100U5VSB | 16.0 | 12.0 | 8.1 | 19,600 | 215575341 |
| 5PX*C007AS3+TSTAT | A952V080CU5SB | 16.0 | 12.0 | 8.1 | 19,400 | 215575344 |
| 5PX*C007AS3+TSTAT | A801X100CM5TD | 16.0 | 12.0 | 8.1 | 19,400 | 215575346 |
| 5PX*C007AS3+TSTAT | A952V080CU5SB | 16.0 | 12.0 | 8.1 | 19,400 | 215575345 |
| 5PX*C007AS3+TSTAT | A801X100CM5TD | 16.0 | 12.0 | 8.1 | 19,400 | 215575347 |
| 5PX*C007AS3+TSTAT | A801X080CM5SD | 16.0 | 12.0 | 8.1 | 19,300 | 215575348 |
| 5PX*C007AS3+TSTAT | A801X080CM5SD | 16.0 | 12.0 | 8.1 | 19,300 | 215575349 |
| 5PX*C007AS3+TSTAT | A952V100CU5SB | 16.0 | 12.0 | 8.1 | 19,200 | 215575350 |
| 5PX*C007AS3+TSTAT | A952V100CU5SB | 16.0 | 12.0 | 8.1 | 19,200 | 215575351 |
| 5PX*C009AS3+TSTAT | A801X080CM5SD | 16.0 | 12.0 | 8.1 | 19,200 | 215575352 |
| 5PX*C009AS3+TSTAT | A801X080CM5SD | 16.0 | 12.0 | 8.1 | 19,200 | 215575353 |
| 5PX*C009AS3+TSTAT | A801X080CM5TD | 16.0 | 12.0 | 8.1 | 19,200 | 215575354 |
| 5PX*C009AS3+TSTAT | A801X080CM5TD | 16.0 | 12.0 | 8.1 | 19,200 | 215575355 |
| 5PX*C009AS3+TSTAT | A801X100CM5SD | 16.0 | 12.0 | 8.1 | 19,600 | 215575356 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,441/yr
- Miami, FL$1,174/yr
- Houston, TX$1,291/yr
- Atlanta, GA$1,298/yr
- Los Angeles, CA$1,261/yr
- New York, NY$3,092/yr
- Chicago, IL$2,508/yr
- Denver, CO$2,084/yr
- Seattle, WA$1,279/yr
- Minneapolis, MN$2,578/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the RunTru A5HP5042A1?
- The RunTru A5HP5042A1 is rated at up to 16.0 SEER2 and 12.0 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 250 certified matchups SEER2 ranges from 15.2-16.0.
- Is the RunTru A5HP5042A1 good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3.5-ton model.
- How much does the RunTru A5HP5042A1 cost to run per year?
- At its rated efficiency it costs about $1,174-$3,092 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,441 in Phoenix and $2,578 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the RunTru A5HP5042A1?
- ENERGY STAR lists 250 certified combinations for this outdoor unit. The highest-rated ones use 5TXCC007AS3+TSTAT, 5TXCD010AS3+TSTAT, A5AHV004A1D3+TDR+TSTAT.
- What refrigerant does the RunTru A5HP5042A1 use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3.5 ton models
- Mainline MPP15AY42AJ2N · cold climate16.0 SEER2 · 8.1 HSPF2
- Ruud RP15AY42AJ2N · cold climate16.0 SEER2 · 8.1 HSPF2
- Mainline MLP15AY42AJ2N · cold climate16.0 SEER2 · 8.1 HSPF2
- Sure SP15AY42AJ2N · cold climate16.0 SEER2 · 8.1 HSPF2
- Luxaire THF2B42T2116.0 SEER2 · 8.1 HSPF2
- TCL THH48HES2NAGOH24 · cold climate16.0 SEER2 · 8.1 HSPF2
- Guardian RHP15042B2116.0 SEER2 · 8.1 HSPF2
- Thermal Zone TZP15AY42AJ2N · cold climate16.0 SEER2 · 8.1 HSPF2
See all 138 3.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 7, 2026. How we use the data.