HVAC Rated

3.5-ton central heat pump · 16 Single-Stage Heat Pump with WeatherGuard Top

Trane 5TWX6048A1

Below average cooling and heating efficiency for a 3.5-ton central heat pump, but not rated for cold climates.

Ranks #85 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,431 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
22,400 BTU/h51% of its 47°F output
Very good · beats 85%

A good fit if…

  • You want a choice of indoor units - 54 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications3.5 ton, R-454B
General
BrandTrane
Outdoor unit model5TWX6048A1
Series16 Single-Stage Heat Pump with WeatherGuard Top
TypeCentral heat pump
Nominal size3.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceFebruary 16, 2026
Last certifiedSeptember 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity44,000-46,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.1
Capacity at 47°F42,000-44,000 BTU/h
Capacity at 17°F28,400-29,000 BTU/h
Capacity at 5°F21,800-22,400 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.14-2.28
ENERGY STAR cold climateNo
Heating output as it gets colder51% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 5TXCC009AS3+TSTAT+P0V0C000M50SD at the standard test temperatures, in BTU/h:

Certified matchups54 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
5TXCC009AS3+TSTAT+P0V0C000M50SD-16.012.08.121,800218110998
5TEMCD07AV51+TDR+TSTAT-16.012.08.121,800218110949
5TEMCD06AV41+TDR+TSTAT-16.012.08.121,800218110948
5PX*D010AS3+TSTAT+P0V0D000M50SD-16.012.08.121,800218110914
5PX*D010AS3+TSTAT+P0V0C000M50SD-16.012.08.121,800218110913
5PX*C009AS3+TSTAT+P0V0C000M50SD-16.012.08.121,800218110859
5TEMCD07BV51+TDR+TSTAT-16.012.08.122,200218788190
5TXCD010AS3+TSTAT+P0V0C000M50SD-16.012.07.821,800218111038
5TEMCD04AV31+TDR+TSTAT-15.212.08.121,800218112577
5TEM6D05AV41+TDR+TSTAT-15.211.78.122,000218112576
5TXCD010AS3+TSTATS9X1D120U5PSB15.212.08.122,000218111047
5TXCD010AS3+TSTATS9X2D120U5PSB15.212.08.122,000218111046
5TXCD010AS3+TSTATS9V2C080U5VSB15.211.78.122,000218111034
5PX*D010AS3+TSTATS8X1D120M5PTC15.212.08.122,000218110927
5PX*D010AS3+TSTATS8X1D120M5PSC15.212.08.122,000218110926
5PX*D010AS3+TSTATS9X1D120U5PSB15.212.08.122,000218110922
5PX*D010AS3+TSTATS9V2C080U5VSB15.211.78.122,000218110919
5PX*D010AS3+TSTATS8X2D120M5PTC15.212.08.122,000218110918
5PX*D010AS3+TSTATS8X2D120M5PSC15.212.08.122,000218110917
5TEMCD05AV41+TDR+TSTAT-15.212.08.121,800218159430
5TEM6D07AV51+TDR+TSTAT-15.212.08.121,800218159429
5TEM6D06AV41+TDR+TSTAT-15.212.08.121,800218159428
5PX*D010AS3+TSTATS9X2D120U5PSB15.212.08.122,000218159424
5PX*D010AS3+TSTATS9V2C100U5VSB15.211.78.122,400218396395
5PX*C009AS3+TSTATS9X2C100U5PSB15.211.78.122,400218396381
5TXCD010AS3+TSTAT*UHMC100CCV415.212.08.122,400218396308
5TXCD010AS3+TSTATS9V2C100U5VSB15.211.78.122,400218396306
5TXCD010AS3+TSTAT*UHMD120CCV515.212.08.122,200218396303
5TXCD010AS3+TSTATS9V2C100U4VSB15.211.78.122,400218396302
5TXCD010AS3+TSTATS9V2D120U5VSB15.212.08.122,200218396301
5TXCC009AS3+TSTATS9X2C100U5PSB15.211.78.122,400218396293
5TXCC009AS3+TSTATS9X1C100U5PSB15.211.78.122,400218396292
5TEM4D07AC51+TDR+TSTAT-15.212.08.122,400218396288
5PX*DD10AS3+TSTAT+P0V0C000M50SD-15.212.08.122,000218396286
5PX*DD10AS3+TSTAT+P0V0D000M50SD-15.212.08.122,000218396285
5PX*C009AS3+TSTATS9X1C100U5PSB15.211.78.122,400218396272
5TXCD010AS3+TSTATS8X1D120M5PSC15.212.08.022,000218111043
5TXCD010AS3+TSTATS8X1D120M5PTC15.212.08.022,000218111042
5TXCD010AS3+TSTAT+P0V0D000M50SD-15.212.08.021,800218111037
5TXCD010AS3+TSTATS8X2D120M5PTC15.212.08.022,000218111033
5TXCD010AS3+TSTATS8X2D120M5PSC15.212.08.022,000218111032
5PX*D010AS3+TSTATS8V2D120M5PDB15.212.08.022,000218110923
5PX*D010AS3+TSTATS8V2D120M5PCB15.212.08.022,000218159423
5PX*D010AS3+TSTATS8X1C100M5PTC15.212.08.022,000218396394
5PX*D010AS3+TSTATL8V1C100U5VSB15.212.08.022,000218396393
5PX*D010AS3+TSTATS8X1C100M5PSC15.212.08.022,000218396385
5PX*D010AS3+TSTATS8X2C100M5PSC15.212.08.022,000218396383
5TXCC009AS3+TSTATS9V2C080U5VSB15.212.08.022,200218396294
5PX*D010AS3+TSTATS8X2C100M5PTC15.212.08.022,000218396284
5PX*D010AS3+TSTATS9V2D120U5VSB15.212.08.022,200218396283
5PX*C009AS3+TSTATS9V2C080U5VSB15.212.08.022,200218396275
5TXCD010AS3+TSTATS8V2D120M5PDB15.212.07.822,000218111028
5TXCD010AS3+TSTATS8V2D120M5PCB15.212.07.822,000218111027
5TXCD010AS3+TSTATL8V1C100U5VSB15.212.07.822,000218111026
Yearly running cost in 10 large cities$1,319-$3,388

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Trane 5TWX6048A1?
The Trane 5TWX6048A1 is rated at up to 16.0 SEER2 and 12.0 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 54 certified matchups SEER2 ranges from 15.2-16.0.
Is the Trane 5TWX6048A1 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3.5-ton model.
How much does the Trane 5TWX6048A1 cost to run per year?
At its rated efficiency it costs about $1,319-$3,388 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,607 in Phoenix and $2,816 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Trane 5TWX6048A1?
ENERGY STAR lists 54 certified combinations for this outdoor unit. The highest-rated ones use 5TXCC009AS3+TSTAT+P0V0C000M50SD, 5TEMCD07AV51+TDR+TSTAT, 5TEMCD06AV41+TDR+TSTAT.
What refrigerant does the Trane 5TWX6048A1 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,585/yrYou save $703/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Trane 5TWX6048A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,585
Current system, per year
$2,288
You save per year
$703
Payback
24.2 years
Net after 10 years
-$9,970

Cooling $990Heating $595Electricity used: 9,904 kWhSaved vs. a minimum-efficiency heat pump: $165

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3.5 ton models

See all 138 3.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 16, 2026. How we use the data.