3.5-ton central heat pump · BHP17L SERIES
Blueridge BHP17L42P-**A
Below average cooling and heating efficiency for a 3.5-ton central heat pump, but not rated for cold climates.
Ranks #89 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,294 a year to run in a mixed climate like Atlanta.
- SEER2
- 15.6 Cooling efficiency over a seasonBelow average · beats 17%
- HSPF2
- 8.3 Heating efficiency over a seasonBelow average · beats 30%
- EER2
- 13.0 Cooling efficiency on a 95°F dayVery good · beats 89%
- Heat at 5°F
- 22,000 BTU/h52% of its 47°F outputAverage · beats 67%
A good fit if…
- You want a choice of indoor units - 37 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Blueridge |
| Outdoor unit model | BHP17L42P-**A |
| Series | BHP17L SERIES |
| Type | Central heat pump |
| Nominal size | 3.5 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | October 25, 2022 |
| Last certified | October 27, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 15.6 (range 15.2-15.6) |
| EER2Efficiency at 95°F outdoors | 12.5-13.0 |
| Cooling capacity | 40,000-41,500 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.3 |
| Capacity at 47°F | 37,600-42,000 BTU/h |
| Capacity at 17°F | 25,000-27,600 BTU/h |
| Capacity at 5°F | 19,600-22,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.02-2.14 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with BC748DCT-0*+TDR at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| BC748DCT-0*+TDR | BG80G1DF110CE20 | 15.6 | 13.0 | 8.3 | 21,800 | 214713552 |
| BC742HBT-0*+TDR | BG802UH090BE16 | 15.6 | 13.0 | 7.8 | 19,900 | 214713522 |
| BE5V42MA4X | - | 15.4 | 13.0 | 8.1 | 20,200 | 210325241 |
| BAH7V42PT-0 | - | 15.4 | 13.0 | 8.1 | 20,200 | 214866131 |
| BC1P49C+TDR+TXV | BG801UH090CE20 | 15.4 | 12.5 | 7.8 | 19,800 | 210325243 |
| BC4X49C+TDR | BG801UH110CE20 | 15.4 | 12.5 | 7.8 | 19,800 | 210441353 |
| BC4X49C+TDR | BG921UH110CE16 | 15.4 | 12.5 | 7.8 | 19,800 | 210441356 |
| BC4X49C+TDR | BG801UH090CE20 | 15.4 | 12.5 | 7.8 | 19,800 | 210441352 |
| BC1P49C+TDR+TXV | BG801UH110CE20 | 15.4 | 12.5 | 7.8 | 19,800 | 210325245 |
| BC1P49C+TDR+TXV | BG921UH110CE16 | 15.4 | 12.5 | 7.8 | 19,800 | 210325253 |
| BC748CCT-0*+TDR | BG801UH110CE20 | 15.4 | 13.0 | 7.8 | 19,600 | 214713564 |
| BC742HBT-0*+TDR | BG802UH090BE12 | 15.4 | 13.0 | 7.8 | 19,900 | 214713521 |
| BC742HBT-0*+TDR | BG801UH070BE12 | 15.4 | 13.0 | 7.8 | 20,200 | 214713523 |
| BC742HBT-0*+TDR | BG801UH090BE16 | 15.4 | 13.0 | 7.8 | 20,000 | 214713524 |
| BC749CCT-0*+TDR | BG801UH090CE20 | 15.4 | 12.5 | 7.8 | 19,800 | 214713572 |
| BC749CCT-0*+TDR | BG801UH110CE20 | 15.4 | 12.5 | 7.8 | 19,800 | 214713573 |
| BC748CCT-0*+TDR | BG921UH110CE16 | 15.4 | 13.0 | 7.8 | 19,600 | 214713567 |
| BC748CCT-0*+TDR | BG921UH110CE20 | 15.4 | 13.0 | 7.8 | 19,900 | 214713568 |
| BC749CCT-0*+TDR | BG921UH110CE16 | 15.4 | 12.5 | 7.8 | 19,800 | 214713576 |
| BC748DCT-0*+TDR | BG96G1DF110CE20 | 15.2 | 13.0 | 8.2 | 22,000 | 214713554 |
| BC1P49C+TDR+TXV | BG961UH110CE20 | 15.2 | 12.5 | 7.8 | 19,900 | 210325249 |
| BC4X49C+TDR | BG921UH110CE20 | 15.2 | 12.5 | 7.8 | 19,900 | 210441357 |
| BC4X49C+TDR | BG921UH090CE16 | 15.2 | 12.5 | 7.8 | 19,800 | 210441355 |
| BC4X49C+TDR | BG961UH110CE20 | 15.2 | 12.5 | 7.8 | 19,900 | 210441359 |
| BC4X49C+TDR | BG961UH090CE16 | 15.2 | 12.5 | 7.8 | 19,900 | 210441358 |
| BC1P49C+TDR+TXV | BG961UH090CE16 | 15.2 | 12.5 | 7.8 | 19,900 | 210325254 |
| BC1P49C+TDR+TXV | BG921UH110CE20 | 15.2 | 12.5 | 7.8 | 19,900 | 210325247 |
| BC1P49C+TDR+TXV | BG921UH090CE16 | 15.2 | 12.5 | 7.8 | 19,800 | 210325251 |
| BC748CCT-0*+TDR | BG801UH090CE20 | 15.2 | 12.5 | 7.8 | 20,000 | 214713563 |
| BC748HCT-0*+TDR | BG801UH110CE20 | 15.2 | 12.5 | 7.8 | 20,200 | 214713544 |
| BC748CCT-0*+TDR | BG921UH090CE16 | 15.2 | 12.5 | 7.8 | 19,600 | 214713566 |
| BC749CCT-0*+TDR | BG921UH090CE16 | 15.2 | 12.5 | 7.8 | 19,800 | 214713575 |
| BC749CCT-0*+TDR | BG921UH110CE20 | 15.2 | 12.5 | 7.8 | 19,900 | 214713577 |
| BC749CCT-0*+TDR | BG961UH090CE16 | 15.2 | 12.5 | 7.8 | 19,900 | 214713578 |
| BC748HBT-0*+TDR | BG801UH090BE16 | 15.2 | 13.0 | 7.8 | 20,200 | 214713539 |
| BC749CCT-0*+TDR | BG961UH110CE20 | 15.2 | 12.5 | 7.8 | 19,900 | 214713579 |
| BH1P48B+TDR | BG801UH090BE16 | 15.2 | 13.0 | 7.8 | 20,200 | 212517537 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,482/yr
- Miami, FL$1,231/yr
- Houston, TX$1,327/yr
- Atlanta, GA$1,294/yr
- Los Angeles, CA$1,248/yr
- New York, NY$3,032/yr
- Chicago, IL$2,450/yr
- Denver, CO$2,028/yr
- Seattle, WA$1,239/yr
- Minneapolis, MN$2,506/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Blueridge BHP17L42P-**A?
- The Blueridge BHP17L42P-**A is rated at up to 15.6 SEER2 and 13.0 EER2 for cooling and up to 8.3 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 37 certified matchups SEER2 ranges from 15.2-15.6.
- Is the Blueridge BHP17L42P-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3.5-ton model.
- How much does the Blueridge BHP17L42P-**A cost to run per year?
- At its rated efficiency it costs about $1,231-$3,032 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,482 in Phoenix and $2,506 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Blueridge BHP17L42P-**A?
- ENERGY STAR lists 37 certified combinations for this outdoor unit. The highest-rated ones use BC748DCT-0*+TDR, BC742HBT-0*+TDR, BE5V42MA4X.
- What refrigerant does the Blueridge BHP17L42P-**A use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3.5 ton models
- Armstrong Air 4SHP17LE142P-**A15.6 SEER2 · 8.3 HSPF2
- Comfort-Aire HRG1542S1R-**A15.6 SEER2 · 8.3 HSPF2
- York YH2F42TB2116.0 SEER2 · 8.1 HSPF2
- Ducane 4HP17L42P-**A15.6 SEER2 · 8.3 HSPF2
- WeatherKing WP15AY42AJ2N · cold climate16.0 SEER2 · 8.1 HSPF2
- GE NS17H42SA4-**A15.6 SEER2 · 8.3 HSPF2
- Trane 5TWX6048A116.0 SEER2 · 8.1 HSPF2
- Lennox EL17XP1-042-230A15.6 SEER2 · 8.3 HSPF2
See all 138 3.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.