HVAC Rated

30,000 BTU mini-split heat pump · N-Series

Ameristar M4THM1930A14N

Below average cooling efficiency and average heating efficiency for a 30,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #151 of 171 30,000 BTU mini-splits for cooling efficiency, and costs about $790 a year to run in a mixed climate like Atlanta.

SEER2
19.0 Cooling efficiency over a season
Below average · beats 9%
HSPF2
10.0 Heating efficiency over a season
Average · beats 43%
EER2
12.5 Cooling efficiency on a 95°F day
Average · beats 44%
Heat at 5°F
22,800 BTU/h76% of its 47°F output
Below average · beats 18%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 22,800 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for mini-splits.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications30,000 BTU, R-410A
General
BrandAmeristar
Also sold asRunTru
Outdoor unit modelM4THM1930A14N
SeriesN-Series
TypeMini-split heat pump
Nominal size30,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceJanuary 1, 2023
Last certifiedJune 13, 2026
Cooling
SEER2Seasonal efficiency, higher is better19.0 (range 19.0)
EER2Efficiency at 95°F outdoors12.5
Cooling capacity28,400 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better10.0
Capacity at 47°F30,000 BTU/h
Capacity at 17°F27,200 BTU/h
Capacity at 5°F22,800 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.84
ENERGY STAR cold climateYes
Heating output as it gets colder76% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:

Certified matchups2 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
- · cold climate19.012.510.022,800210488261
- RUNTRU · cold climate19.012.510.022,800210488276
Yearly running cost in 10 large cities$703-$1,892

At each state's average electricity price and the city's typical heating and cooling hours.

Questions4
What is the SEER2 rating of the Ameristar M4THM1930A14N?
The Ameristar M4THM1930A14N is rated at up to 19.0 SEER2 and 12.5 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the Ameristar M4THM1930A14N good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 22,800 BTU/h at 5°F with a COP of 1.84, so it is still 1.8 times as efficient as electric resistance heat at that temperature.
How much does the Ameristar M4THM1930A14N cost to run per year?
At its rated efficiency it costs about $703-$1,892 a year in electricity in large U.S. cities, depending on climate and local rates - for example $868 in Phoenix and $1,582 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
What refrigerant does the Ameristar M4THM1930A14N use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $862/yrYou save $628/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Ameristar M4THM1930A14N
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$862
Current system, per year
$1,491
You save per year
$628
Payback
16.7 years
Net after 10 years
-$4,216

Cooling $526Heating $336Electricity used: 5,388 kWhSaved vs. a minimum-efficiency heat pump: $285

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 30,000 BTU models

See all 171 30,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 13, 2026. How we use the data.