HVAC Rated

30,000 BTU mini-split heat pump · Y400

York YRACDJ36WHBA

Below average cooling and heating efficiency for a 30,000 BTU mini-split heat pump, but not rated for cold climates.

Ranks #154 of 171 30,000 BTU mini-splits for cooling efficiency, and costs about $968 a year to run in a mixed climate like Atlanta.

SEER2
19.0 Cooling efficiency over a season
Below average · beats 9%
HSPF2
9.5 Heating efficiency over a season
Below average · beats 24%
EER2
9.5 Cooling efficiency on a 95°F day
Below average · beats 3%
Heat at 5°F
24,000 BTU/h67% of its 47°F output
Very good · beats 73%

A good fit if…

  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for mini-splits.
  • You mainly need heat - its HSPF2 is below average for mini-splits.

Calculate my running cost

Details

Specifications30,000 BTU, R-32
General
BrandYork
Also sold asHitachi
Outdoor unit modelYRACDJ36WHBA
SeriesY400
TypeMini-split heat pump
Nominal size30,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-32
Connected (smart) capableNo
On the market sinceMay 12, 2026
Last certifiedMay 28, 2026
Cooling
SEER2Seasonal efficiency, higher is better19.0 (range 19.0)
EER2Efficiency at 95°F outdoors9.5
Cooling capacity33,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.5
Capacity at 47°F36,000 BTU/h
Capacity at 17°F25,200 BTU/h
Capacity at 5°F24,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.15
ENERGY STAR cold climateNo
Heating output as it gets colder67% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with YRAKDJ36PHBA at the standard test temperatures, in BTU/h:

Certified matchups1 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
YRAKDJ36PHBA YORK19.09.59.524,000218451262
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the York YRACDJ36WHBA: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$819-$2,353

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the York YRACDJ36WHBA?
The York YRACDJ36WHBA is rated at up to 19.0 SEER2 and 9.5 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the York YRACDJ36WHBA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 30,000 BTU model.
How much does the York YRACDJ36WHBA cost to run per year?
At its rated efficiency it costs about $819-$2,353 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,032 in Phoenix and $1,983 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the York YRACDJ36WHBA the same as the Hitachi RAC-DJ36WHBA?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the York YRACDJ36WHBA?
ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses YORK YRAKDJ36PHBA.
What refrigerant does the York YRACDJ36WHBA use?
It uses R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,036/yrYou save $715/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump York YRACDJ36WHBA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,036
Current system, per year
$1,751
You save per year
$715
Payback
17.5 years
Net after 10 years
-$5,351

Cooling $611Heating $424Electricity used: 6,474 kWhSaved vs. a minimum-efficiency heat pump: $314

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 30,000 BTU models

See all 171 30,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 28, 2026. How we use the data.