HVAC Rated

2.5-ton central heat pump · BHP17 SERIES

Blueridge BHP17L30P-**A

Below average cooling efficiency and average heating efficiency for a 2.5-ton central heat pump, but not rated for cold climates.

Ranks #115 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $889 a year to run in a mixed climate like Atlanta.

SEER2
16.2 Cooling efficiency over a season
Below average · beats 36%
HSPF2
8.6 Heating efficiency over a season
Average · beats 45%
EER2
13.5 Cooling efficiency on a 95°F day
Excellent · beats 95%
Heat at 5°F
15,400 BTU/h49% of its 47°F output
Excellent · beats 92%

A good fit if…

  • You want a choice of indoor units - 139 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications2.5 ton, R-410A
General
BrandBlueridge
Outdoor unit modelBHP17L30P-**A
SeriesBHP17 SERIES
TypeCentral heat pump
Nominal size2.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceJanuary 6, 2022
Last certifiedOctober 27, 2025
Cooling
SEER2Seasonal efficiency, higher is better16.2 (range 15.4-16.2)
EER2Efficiency at 95°F outdoors12.2-13.5
Cooling capacity28,200-30,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.6
Capacity at 47°F26,600-30,000 BTU/h
Capacity at 17°F17,400-19,600 BTU/h
Capacity at 5°F13,200-15,400 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.98-2.34
ENERGY STAR cold climateNo
Heating output as it gets colder49% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with BD4X-42B+TDR at the standard test temperatures, in BTU/h:

Certified matchups139 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 139 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
BD4X-42B+TDRBG80G1DF090BE1616.213.58.614,800213265511
BC742DBT-0*+TDRBG80G1DF090BE1616.213.58.614,800214713404
BC1P36A+TDR+TXVBG801UH090BE1616.213.08.114,100210325399
BC1P36A+TDR+TXVBG802UH090BE1616.213.08.114,100210325401
BC1P36B+TDR+TXVBG801UH090BE1616.213.08.114,100210441262
BC4X36B+TDRBG801UH090BE1616.213.08.114,100210441297
BC4X36B+TDRBG802UH090BE1616.213.08.114,100210441294
BC1P36B+TDR+TXVBG802UH090BE1616.213.08.114,100210441259
BC4X36B+TDRBG802UH090BE1216.213.08.114,300210441293
BC1P36B+TDR+TXVBG802UH090BE1216.213.08.114,300210441258
BC1P36A+TDR+TXVBG802UH090BE1216.213.08.114,300210325411
BC736CBT-0*+TDRBG802UH090BE1216.213.08.114,300214713426
BC736CBT-0*+TDRBG802UH090BE1616.213.08.114,100214713427
BC736CBT-0*+TDRBG801UH090BE1616.213.08.114,100214713429
BC730HBT-0*+TDRBG802UH090BE1216.213.08.013,500214713384
BC730HBT-0*+TDRBG801UH090BE1616.213.07.813,400214713387
BC730HBT-0*+TDRBG802UH090BE1616.213.07.813,400214713385
BC730HBT-0*+TDRBG801UH070BE1216.213.07.813,400214713386
BAH7E36PT-0-16.012.58.513,200214866172
BC1P36A+TDR+TXVBG801UH070BE1216.013.08.114,300210325413
BC1P36A+TDR+TXVBG921UH070BE1216.013.08.114,400210325405
BC1P36A+TDR+TXVBG802UH070AE1216.013.08.114,300210325391
BC4X36B+TDRBG921UH070BE1216.013.08.114,400210441299
BC4X36B+TDRBG802UH090BV1616.013.08.114,400210441302
BC4X36B+TDRBG801UH070BE1216.013.08.114,300210441296
BC4X36A+TDRBG801UH045AE1216.013.08.114,400210441289
BC1P36B+TDR+TXVBG921UH070BE1216.013.08.114,400210441264
BC4X36A+TDRBG802UH070AE1216.013.08.114,300210441288
BC1P36B+TDR+TXVBG801UH070BE1216.013.08.114,300210441261
BC1P36B+TDR+TXVBG802UH090BV1616.013.08.114,400210441267
BC1P36A+TDR+TXVBG801UH070AE1216.013.08.114,400210325395
BC4X36A+TDRBG801UH070AE1216.013.08.114,400210441290
BC1P36A+TDR+TXVBG801UH045AE1216.013.08.114,400210325393
BC1P36A+TDR+TXVBG802UH090BV1616.013.08.114,400210325414
BC736CAT-0*+TDRBG801UH045AE1216.013.08.114,400214713422
BC736CAT-0*+TDRBG801UH070AE1216.013.08.114,400214713423
BC736CAT-0*+TDRBG802UH070AE1216.013.08.114,300214713421
BC736CBT-0*+TDRBG801UH070BE1216.013.08.114,300214713428
BC736CBT-0*+TDRBG921UH070BE1216.013.08.114,400214713431
BC736CBT-0*+TDRBG802UH090BV1616.013.08.114,400214713434
BC1P30A+TDR+TXVBG801UH090BE1616.013.08.014,200210325371
BC4X30B+TDRBG801UH090BE1616.013.08.014,200210441282
BC1P30B+TDR+TXVBG801UH090BE1616.013.08.014,200210441252
BC4X30B+TDRBG802UH090BE1616.013.08.014,200210441279
BC1P30B+TDR+TXVBG802UH090BE1616.013.08.014,200210441249
BC1P30A+TDR+TXVBG802UH090BE1616.013.08.014,200210325372
BC730HBT-0*+TDRBG802UH090BV1616.013.08.013,700214713392
BC730CBT-0*+TDRBG801UH090BE1616.013.08.014,200214713414
BC730CBT-0*+TDRBG802UH090BE1616.013.08.014,200214713412
BC730HBT-0*+TDRBG921UH070BE1216.013.07.813,600214713389
BD4X-42B+TDRBG802DF070AE1215.813.08.615,100213265510
BC742DBT-0*+TDRBG802DF070AE1215.813.08.615,100214713403
BH1P36C*+TDR+TXVBG801UH090CE2015.813.08.514,800211736060
BC736HCT-0*+TDRBG801UH090CE2015.813.08.514,800214713393
BH1P36C*+TDR+TXVBG921UH110CE1615.813.08.314,700211736122
BC736HCT-0*+TDRBG921UH110CE1615.813.08.314,700214713397
BE5V36MA4X-15.812.58.113,400211174401
BC1P36A+TDR+TXVBG921UH045BE1215.813.08.114,300210325403
BC4X36B+TDRBG921UH045BE1215.813.08.114,300210441298
BC4X30B+TDRBG802UH090BE1215.813.08.114,300210441278
Yearly running cost in 10 large cities$844-$2,085

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Blueridge BHP17L30P-**A?
The Blueridge BHP17L30P-**A is rated at up to 16.2 SEER2 and 13.5 EER2 for cooling and up to 8.6 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 139 certified matchups SEER2 ranges from 15.4-16.2.
Is the Blueridge BHP17L30P-**A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2.5-ton model.
How much does the Blueridge BHP17L30P-**A cost to run per year?
At its rated efficiency it costs about $844-$2,085 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,017 in Phoenix and $1,723 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Blueridge BHP17L30P-**A?
ENERGY STAR lists 139 certified combinations for this outdoor unit. The highest-rated ones use BD4X-42B+TDR, BC742DBT-0*+TDR, BC1P36A+TDR+TXV.
What refrigerant does the Blueridge BHP17L30P-**A use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $997/yrYou save $486/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Blueridge BHP17L30P-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$997
Current system, per year
$1,483
You save per year
$486
Payback
22.6 years
Net after 10 years
-$6,138

Cooling $634Heating $362Electricity used: 6,228 kWhSaved vs. a minimum-efficiency heat pump: $137

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2.5 ton models

See all 199 2.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.