2.5-ton central heat pump · BHP17 SERIES
Blueridge BHP17L30P-**A
Below average cooling efficiency and average heating efficiency for a 2.5-ton central heat pump, but not rated for cold climates.
Ranks #115 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $889 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.2 Cooling efficiency over a seasonBelow average · beats 36%
- HSPF2
- 8.6 Heating efficiency over a seasonAverage · beats 45%
- EER2
- 13.5 Cooling efficiency on a 95°F dayExcellent · beats 95%
- Heat at 5°F
- 15,400 BTU/h49% of its 47°F outputExcellent · beats 92%
A good fit if…
- You want a choice of indoor units - 139 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | Blueridge |
| Outdoor unit model | BHP17L30P-**A |
| Series | BHP17 SERIES |
| Type | Central heat pump |
| Nominal size | 2.5 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | January 6, 2022 |
| Last certified | October 27, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.2 (range 15.4-16.2) |
| EER2Efficiency at 95°F outdoors | 12.2-13.5 |
| Cooling capacity | 28,200-30,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.6 |
| Capacity at 47°F | 26,600-30,000 BTU/h |
| Capacity at 17°F | 17,400-19,600 BTU/h |
| Capacity at 5°F | 13,200-15,400 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.98-2.34 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with BD4X-42B+TDR at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 139 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| BD4X-42B+TDR | BG80G1DF090BE16 | 16.2 | 13.5 | 8.6 | 14,800 | 213265511 |
| BC742DBT-0*+TDR | BG80G1DF090BE16 | 16.2 | 13.5 | 8.6 | 14,800 | 214713404 |
| BC1P36A+TDR+TXV | BG801UH090BE16 | 16.2 | 13.0 | 8.1 | 14,100 | 210325399 |
| BC1P36A+TDR+TXV | BG802UH090BE16 | 16.2 | 13.0 | 8.1 | 14,100 | 210325401 |
| BC1P36B+TDR+TXV | BG801UH090BE16 | 16.2 | 13.0 | 8.1 | 14,100 | 210441262 |
| BC4X36B+TDR | BG801UH090BE16 | 16.2 | 13.0 | 8.1 | 14,100 | 210441297 |
| BC4X36B+TDR | BG802UH090BE16 | 16.2 | 13.0 | 8.1 | 14,100 | 210441294 |
| BC1P36B+TDR+TXV | BG802UH090BE16 | 16.2 | 13.0 | 8.1 | 14,100 | 210441259 |
| BC4X36B+TDR | BG802UH090BE12 | 16.2 | 13.0 | 8.1 | 14,300 | 210441293 |
| BC1P36B+TDR+TXV | BG802UH090BE12 | 16.2 | 13.0 | 8.1 | 14,300 | 210441258 |
| BC1P36A+TDR+TXV | BG802UH090BE12 | 16.2 | 13.0 | 8.1 | 14,300 | 210325411 |
| BC736CBT-0*+TDR | BG802UH090BE12 | 16.2 | 13.0 | 8.1 | 14,300 | 214713426 |
| BC736CBT-0*+TDR | BG802UH090BE16 | 16.2 | 13.0 | 8.1 | 14,100 | 214713427 |
| BC736CBT-0*+TDR | BG801UH090BE16 | 16.2 | 13.0 | 8.1 | 14,100 | 214713429 |
| BC730HBT-0*+TDR | BG802UH090BE12 | 16.2 | 13.0 | 8.0 | 13,500 | 214713384 |
| BC730HBT-0*+TDR | BG801UH090BE16 | 16.2 | 13.0 | 7.8 | 13,400 | 214713387 |
| BC730HBT-0*+TDR | BG802UH090BE16 | 16.2 | 13.0 | 7.8 | 13,400 | 214713385 |
| BC730HBT-0*+TDR | BG801UH070BE12 | 16.2 | 13.0 | 7.8 | 13,400 | 214713386 |
| BAH7E36PT-0 | - | 16.0 | 12.5 | 8.5 | 13,200 | 214866172 |
| BC1P36A+TDR+TXV | BG801UH070BE12 | 16.0 | 13.0 | 8.1 | 14,300 | 210325413 |
| BC1P36A+TDR+TXV | BG921UH070BE12 | 16.0 | 13.0 | 8.1 | 14,400 | 210325405 |
| BC1P36A+TDR+TXV | BG802UH070AE12 | 16.0 | 13.0 | 8.1 | 14,300 | 210325391 |
| BC4X36B+TDR | BG921UH070BE12 | 16.0 | 13.0 | 8.1 | 14,400 | 210441299 |
| BC4X36B+TDR | BG802UH090BV16 | 16.0 | 13.0 | 8.1 | 14,400 | 210441302 |
| BC4X36B+TDR | BG801UH070BE12 | 16.0 | 13.0 | 8.1 | 14,300 | 210441296 |
| BC4X36A+TDR | BG801UH045AE12 | 16.0 | 13.0 | 8.1 | 14,400 | 210441289 |
| BC1P36B+TDR+TXV | BG921UH070BE12 | 16.0 | 13.0 | 8.1 | 14,400 | 210441264 |
| BC4X36A+TDR | BG802UH070AE12 | 16.0 | 13.0 | 8.1 | 14,300 | 210441288 |
| BC1P36B+TDR+TXV | BG801UH070BE12 | 16.0 | 13.0 | 8.1 | 14,300 | 210441261 |
| BC1P36B+TDR+TXV | BG802UH090BV16 | 16.0 | 13.0 | 8.1 | 14,400 | 210441267 |
| BC1P36A+TDR+TXV | BG801UH070AE12 | 16.0 | 13.0 | 8.1 | 14,400 | 210325395 |
| BC4X36A+TDR | BG801UH070AE12 | 16.0 | 13.0 | 8.1 | 14,400 | 210441290 |
| BC1P36A+TDR+TXV | BG801UH045AE12 | 16.0 | 13.0 | 8.1 | 14,400 | 210325393 |
| BC1P36A+TDR+TXV | BG802UH090BV16 | 16.0 | 13.0 | 8.1 | 14,400 | 210325414 |
| BC736CAT-0*+TDR | BG801UH045AE12 | 16.0 | 13.0 | 8.1 | 14,400 | 214713422 |
| BC736CAT-0*+TDR | BG801UH070AE12 | 16.0 | 13.0 | 8.1 | 14,400 | 214713423 |
| BC736CAT-0*+TDR | BG802UH070AE12 | 16.0 | 13.0 | 8.1 | 14,300 | 214713421 |
| BC736CBT-0*+TDR | BG801UH070BE12 | 16.0 | 13.0 | 8.1 | 14,300 | 214713428 |
| BC736CBT-0*+TDR | BG921UH070BE12 | 16.0 | 13.0 | 8.1 | 14,400 | 214713431 |
| BC736CBT-0*+TDR | BG802UH090BV16 | 16.0 | 13.0 | 8.1 | 14,400 | 214713434 |
| BC1P30A+TDR+TXV | BG801UH090BE16 | 16.0 | 13.0 | 8.0 | 14,200 | 210325371 |
| BC4X30B+TDR | BG801UH090BE16 | 16.0 | 13.0 | 8.0 | 14,200 | 210441282 |
| BC1P30B+TDR+TXV | BG801UH090BE16 | 16.0 | 13.0 | 8.0 | 14,200 | 210441252 |
| BC4X30B+TDR | BG802UH090BE16 | 16.0 | 13.0 | 8.0 | 14,200 | 210441279 |
| BC1P30B+TDR+TXV | BG802UH090BE16 | 16.0 | 13.0 | 8.0 | 14,200 | 210441249 |
| BC1P30A+TDR+TXV | BG802UH090BE16 | 16.0 | 13.0 | 8.0 | 14,200 | 210325372 |
| BC730HBT-0*+TDR | BG802UH090BV16 | 16.0 | 13.0 | 8.0 | 13,700 | 214713392 |
| BC730CBT-0*+TDR | BG801UH090BE16 | 16.0 | 13.0 | 8.0 | 14,200 | 214713414 |
| BC730CBT-0*+TDR | BG802UH090BE16 | 16.0 | 13.0 | 8.0 | 14,200 | 214713412 |
| BC730HBT-0*+TDR | BG921UH070BE12 | 16.0 | 13.0 | 7.8 | 13,600 | 214713389 |
| BD4X-42B+TDR | BG802DF070AE12 | 15.8 | 13.0 | 8.6 | 15,100 | 213265510 |
| BC742DBT-0*+TDR | BG802DF070AE12 | 15.8 | 13.0 | 8.6 | 15,100 | 214713403 |
| BH1P36C*+TDR+TXV | BG801UH090CE20 | 15.8 | 13.0 | 8.5 | 14,800 | 211736060 |
| BC736HCT-0*+TDR | BG801UH090CE20 | 15.8 | 13.0 | 8.5 | 14,800 | 214713393 |
| BH1P36C*+TDR+TXV | BG921UH110CE16 | 15.8 | 13.0 | 8.3 | 14,700 | 211736122 |
| BC736HCT-0*+TDR | BG921UH110CE16 | 15.8 | 13.0 | 8.3 | 14,700 | 214713397 |
| BE5V36MA4X | - | 15.8 | 12.5 | 8.1 | 13,400 | 211174401 |
| BC1P36A+TDR+TXV | BG921UH045BE12 | 15.8 | 13.0 | 8.1 | 14,300 | 210325403 |
| BC4X36B+TDR | BG921UH045BE12 | 15.8 | 13.0 | 8.1 | 14,300 | 210441298 |
| BC4X30B+TDR | BG802UH090BE12 | 15.8 | 13.0 | 8.1 | 14,300 | 210441278 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,017/yr
- Miami, FL$844/yr
- Houston, TX$910/yr
- Atlanta, GA$889/yr
- Los Angeles, CA$858/yr
- New York, NY$2,085/yr
- Chicago, IL$1,685/yr
- Denver, CO$1,395/yr
- Seattle, WA$852/yr
- Minneapolis, MN$1,723/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Blueridge BHP17L30P-**A?
- The Blueridge BHP17L30P-**A is rated at up to 16.2 SEER2 and 13.5 EER2 for cooling and up to 8.6 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 139 certified matchups SEER2 ranges from 15.4-16.2.
- Is the Blueridge BHP17L30P-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2.5-ton model.
- How much does the Blueridge BHP17L30P-**A cost to run per year?
- At its rated efficiency it costs about $844-$2,085 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,017 in Phoenix and $1,723 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Blueridge BHP17L30P-**A?
- ENERGY STAR lists 139 certified combinations for this outdoor unit. The highest-rated ones use BD4X-42B+TDR, BC742DBT-0*+TDR, BC1P36A+TDR+TXV.
- What refrigerant does the Blueridge BHP17L30P-**A use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2.5 ton models
- Armstrong Air 4SHP17LE130P-**A16.2 SEER2 · 8.6 HSPF2
- Comfort-Aire HRG1530S1R-**A16.2 SEER2 · 8.6 HSPF2
- AI AIR CONDITIONING AUO18-30N1-M3H · cold climate16.2 SEER2 · 8.9 HSPF2
- Concord 4HP17L30P-**A16.2 SEER2 · 8.6 HSPF2
- Panasonic CU-HE30YAHK6 · cold climate16.2 SEER2 · 9.7 HSPF2
- GE NS17H30SA4-**A16.2 SEER2 · 8.6 HSPF2
- Midea DLCURAH30ABK · cold climate16.2 SEER2 · 9.7 HSPF2
- Lennox EL17XP1-030-230A16.2 SEER2 · 8.6 HSPF2
See all 199 2.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.