2.5-ton central heat pump · HRG15 SERIES

Comfort-Aire HRG1530S1R-**A

Below average cooling efficiency and average heating efficiency for a 2.5-ton central heat pump, but not rated for cold climates.

Ranks #116 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $889 a year to run in a mixed climate like Atlanta.

SEER2
16.2 Cooling efficiency over a season
Below average · beats 36%
HSPF2
8.6 Heating efficiency over a season
Average · beats 45%
EER2
13.5 Cooling efficiency on a 95°F day
Excellent · beats 95%
Heat at 5°F
15,400 BTU/h49% of its 47°F output
Excellent · beats 92%

A good fit if…

  • You want a choice of indoor units - 156 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications2.5 ton, R-410A
General
BrandComfort-Aire
Also sold asCentury
Outdoor unit modelHRG1530S1R-**A
SeriesHRG15 SERIES
TypeCentral heat pump
Nominal size2.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceOctober 25, 2022
Last certifiedOctober 27, 2025
Cooling
SEER2Seasonal efficiency, higher is better16.2 (range 15.2-16.2)
EER2Efficiency at 95°F outdoors12.5-13.5
Cooling capacity28,200-30,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.6
Capacity at 47°F27,200-30,000 BTU/h
Capacity at 17°F17,400-19,600 BTU/h
Capacity at 5°F13,400-15,400 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.96-2.34
ENERGY STAR cold climateNo
Heating output as it gets colder49% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EAD4X-42B+TDR at the standard test temperatures, in BTU/h:

Certified matchups156 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 156 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
EAD4X-42B+TDRGDD80C090B4M16.213.58.614,800213265480
EAD4X-42B+TDRGDD80C090B4M16.213.58.614,800213265430
7ED42BX-0*+TDRGDD80C090B4M16.213.58.614,800214712953
7ED42BX-0*+TDRGDD80C090B4M16.213.58.614,800214716777
EA(C;U)1P36A+TDR+TXVGUH80C090B4M16.213.08.114,100210330442
EA(C;U)1P36A+TDR+TXVGUH80C090B4M16.213.08.114,100210331358
7EC36BX-0*+TDRGUH80C090B4M16.213.08.114,100214712978
7EC36BX-0*+TDRGUH80C090B4M16.213.08.114,100214716802
7EH30BX-0*+TDRGUH80C070B3M16.213.07.813,400214712931
7EH30BX-0*+TDRGUH80C090B4M16.213.07.813,400214712932
7EH30BX-0*+TDRGUH80C070B3M16.213.07.813,400214716755
7EH30BX-0*+TDRGUH80C090B4M16.213.07.813,400214716756
EA(C;U)1P36A+TDR+TXVGUH92C070B3M16.013.08.114,400210331360
EA(C;U)1P36A+TDR+TXVGUH80C045A3M16.013.08.114,400210331356
EA(C;U)1P36A+TDR+TXVGUH97M070B3M16.013.08.114,500210331366
EA(C;U)1P36A+TDR+TXVGUH80C070A3M16.013.08.114,400210331357
EA(C;U)1P36A+TDR+TXVGUH80C070B3M16.013.08.114,300210330447
EA(C;U)1P36A+TDR+TXVGUH80C045A3M16.013.08.114,400210330440
EA(C;U)1P36A+TDR+TXVGUH97M070B3M16.013.08.114,500210330450
EA(C;U)1P36A+TDR+TXVGUH92C070B3M16.013.08.114,400210330444
EA(C;U)1P36A+TDR+TXVGUH80C070A3M16.013.08.114,400210330441
EA(C;U)1P36A+TDR+TXVGUH80C070B3M16.013.08.114,300210331363
7EC36AX-0*+TDRGUH80C070A3M16.013.08.114,400214712974
7EC36BX-0*+TDRGUH80C070B3M16.013.08.114,300214712977
7EC36BX-0*+TDRGUH92C070B3M16.013.08.114,400214712980
7EC36BX-0*+TDRGUH97M070B3M16.013.08.114,500214712983
7EC36BX-0*+TDRGUH92C070B3M16.013.08.114,400214716804
7EC36BX-0*+TDRGUH97M070B3M16.013.08.114,500214716807
7EC36AX-0*+TDRGUH80C045A3M16.013.08.114,400214716797
7EC36AX-0*+TDRGUH80C070A3M16.013.08.114,400214716798
7EC36BX-0*+TDRGUH80C070B3M16.013.08.114,300214716801
7EC36AX-0*+TDRGUH80C045A3M16.013.08.114,400214712973
EA(C;U)1P30A+TDR+TXVGUH80C090B4M16.013.08.014,200210330431
EA(C;U)1P30A+TDR+TXVGUH80C090B4M16.013.08.014,200210331346
7EC30BX-0*+TDRGUH80C090B4M16.013.08.014,200214712964
7EC30BX-0*+TDRGUH80C090B4M16.013.08.014,200214716788
7EH30BX-0*+TDRGUH92C070B3M16.013.07.813,600214712934
7EH30BX-0*+TDRGUH92C070B3M16.013.07.813,600214716758
EAD4X-42B+TDRGDD80C070B3M15.813.08.615,300213265479
EAD4X-42B+TDRGDD92C045B3M15.813.08.615,300213265481
EAD4X-42B+TDRGDD92C070B3M15.813.08.615,300213265482
EAD4X-42B+TDRGDD80C070B3M15.813.08.615,300213265429
EAD4X-42B+TDRGDD92C045B3M15.813.08.615,300213265431
EAD4X-42B+TDRGDD92C070B3M15.813.08.615,300213265432
7ED42BX-0*+TDRGDD80C070B3M15.813.08.615,300214712952
7ED42BX-0*+TDRGDD92C045B3M15.813.08.615,300214712954
7ED42BX-0*+TDRGDD92C070B3M15.813.08.615,300214712955
7ED42BX-0*+TDRGDD92C045B3M15.813.08.615,300214716778
7ED42BX-0*+TDRGDD80C070B3M15.813.08.615,300214716776
7ED42BX-0*+TDRGDD92C070B3M15.813.08.615,300214716779
7EH36CX-0*+TDRGUH80C090C5M15.813.08.514,800214712939
7EH36CX-0*+TDRGUH80C090C5M15.813.08.514,800214716763
7EH36CX-0*+TDRGUH92C110C4M15.813.08.314,700214712943
7EH36CX-0*+TDRGUH92C110C4M15.813.08.314,700214716767
HCG36V1P-15.812.58.113,400211174403
HCG36V1P-15.812.58.113,400211174402
EA(C;U)1P36A+TDR+TXVGUH92C045B3M15.813.08.114,300210330443
EA(C;U)1P36A+TDR+TXVGUH92C045B3M15.813.08.114,300210331359
7EC36BX-0*+TDRGUH92C045B3M15.813.08.114,300214712979
7EC36BX-0*+TDRGUH92C045B3M15.813.08.114,300214716803
Yearly running cost in 10 large cities$844-$2,085

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Comfort-Aire HRG1530S1R-**A?
The Comfort-Aire HRG1530S1R-**A is rated at up to 16.2 SEER2 and 13.5 EER2 for cooling and up to 8.6 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 156 certified matchups SEER2 ranges from 15.2-16.2.
Is the Comfort-Aire HRG1530S1R-**A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2.5-ton model.
How much does the Comfort-Aire HRG1530S1R-**A cost to run per year?
At its rated efficiency it costs about $844-$2,085 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,017 in Phoenix and $1,723 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Comfort-Aire HRG1530S1R-**A?
ENERGY STAR lists 156 certified combinations for this outdoor unit. The highest-rated ones use EAD4X-42B+TDR, 7ED42BX-0*+TDR, EA(C;U)1P36A+TDR+TXV.
What refrigerant does the Comfort-Aire HRG1530S1R-**A use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $997/yrYou save $486/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Comfort-Aire HRG1530S1R-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$997
Current system, per year
$1,483
You save per year
$486
Payback
22.6 years
Net after 10 years
-$6,138

Cooling $634Heating $362Electricity used: 6,228 kWhSaved vs. a minimum-efficiency heat pump: $137

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2.5 ton models

See all 199 2.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.