HVAC Rated

1.5-ton central heat pump · 15 SEER2 HP

Bryant PH5SAN518**AA

Below average cooling and heating efficiency for a 1.5-ton central heat pump, but not rated for cold climates.

Ranks #139 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $575 a year to run in a mixed climate like Atlanta.

SEER2
15.5 Cooling efficiency over a season
Below average · beats 15%
HSPF2
8.0 Heating efficiency over a season
Below average · beats 12%
EER2
12.5 Cooling efficiency on a 95°F day
Very good · beats 80%
Heat at 5°F
8,600 BTU/h46% of its 47°F output
Average · beats 58%

A good fit if…

  • You want a choice of indoor units - 163 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications1.5 ton, R-454B
General
BrandBryant
Also sold asPAYNE HEATING AND COOLING, WeatherMaker, BROCK
Outdoor unit modelPH5SAN518**AA
Series15 SEER2 HP
TypeCentral heat pump
Nominal size1.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJuly 1, 2022
Last certifiedSeptember 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better15.5 (range 15.2-15.5)
EER2Efficiency at 95°F outdoors11.7-12.5
Cooling capacity17,400-18,900 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.0
Capacity at 47°F16,400-18,300 BTU/h
Capacity at 17°F10,500-11,000 BTU/h
Capacity at 5°F8,200-8,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.88-2.10
ENERGY STAR cold climateNo
Heating output as it gets colder46% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FMA5X24**AL at the standard test temperatures, in BTU/h:

Certified matchups163 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 163 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FMA5X24**AL-15.512.58.08,200214423922
FMA5X24**AL-15.512.58.08,200214423921
FMA5X24**AL-15.512.58.08,200214423923
FMA5X24**AL-15.512.58.08,200214423924
CVAMA3217XMA8(0,1)*SB36070M17***15.512.07.88,200214195438
CVAMA3217XMAPG80MS(A,L)A36070B**15.512.07.88,200214195439
CVAMA3217XMAPG80MS(A,L)A36070B**15.512.07.88,200214195440
CVAMA3217XMAPG80MS(A,L)A36070B**15.512.07.88,200214195441
CVAMA3217XMAPG80MS(A,L)A48070B**15.512.07.88,200214195469
CVAMA3217XMA8(0,1)*SB48070M17***15.512.07.88,200214195468
CVAMA3217XMAPG80MS(A,L)A48070B**15.512.07.88,200214195470
CVAMA3217XMAPG80MS(A,L)A48070B**15.512.07.88,200214195471
FM(C,U)5Z18**AL-15.212.08.08,500215828781
FM(C,U)5Z18**AL-15.212.08.08,500215828782
FM(C,U)5Z18**AL-15.212.08.08,500215828783
FM(C,U)5Z18**AL-15.212.08.08,500215828784
FM(C,U)5Z24**AL-15.212.08.08,500215828813
FM(C,U)5Z24**AL-15.212.08.08,500215828814
FM(C,U)5Z24**AL-15.212.08.08,500215828815
FM(C,U)5Z24**AL-15.212.08.08,500215828816
FM(C,U)5S30**AL-15.212.08.08,600218452517
FM(C,U)5S30**AL-15.212.08.08,600218452516
FM(C,U)5S30**AL-15.212.08.08,600218452515
FM(C,U)5S30**AL-15.212.08.08,600218452514
CAA**2517AM82*TB36045V14***15.212.07.88,400214126675
CAA**2517AMPG80VTLB36045A**15.212.07.88,400214126676
CAA**2517AMPG80VTLB36045A**15.212.07.88,400214126677
CAA**1917AM8(0,1)*SB36045M14***15.212.07.88,400214124773
CAA**1917AMPG80MS(A,L)A36045A**15.212.07.88,400214124775
CAA**1917AMPG80MS(A,L)A36045A**15.212.07.88,400214124774
CAA**1917AMPG80MS(A,L)A36045A**15.212.07.88,400214124776
CAA**1917AM8(0,1)*SB36070M14***15.212.07.88,400214124803
CAA**1917AMPG80MS(A,L)A36070A**15.212.07.88,400214124805
CAA**1917AMPG80MS(A,L)A36070A**15.212.07.88,400214124804
CAA**1917AMPG80MS(A,L)A36070A**15.212.07.88,400214124806
CAA**1917AMPG80MS(A,L)A36070B**15.212.07.88,300214124834
CAA**1917AM8(0,1)*SB36070M17***15.212.07.88,300214124833
CAA**1917AMPG80MS(A,L)A36070B**15.212.07.88,300214124835
CAA**1917AMPG80MS(A,L)A36070B**15.212.07.88,300214124836
CAA**2517AM8(0,1)*SB36045M14***15.212.07.88,400214126086
CAA**2517AMPG80MS(A,L)A36045A**15.212.07.88,400214126087
CAA**2517AMPG80MS(A,L)A36045A**15.212.07.88,400214126088
CAA**2517AMPG80MS(A,L)A36045A**15.212.07.88,400214126089
CAA**2517AMPG80VTLB36045A**15.212.07.88,400214126678
CAA**2517AM82*TB36070V14***15.212.07.88,400214126705
CAA**2517AMPG80VTLB36070A**15.212.07.88,400214126706
CAA**2517AMPG80VTLB36070A**15.212.07.88,400214126707
CAA**2517AMPG80VTLB36070A**15.212.07.88,400214126708
CAA**1917AM82*TB36070V14***15.211.77.88,400214125316
CAA**1917AMPG80VTLB36070A**15.211.77.88,400214125317
CAA**1917AMPG80VTLB36070A**15.211.77.88,400214125318
CAA**1917AMPG80VTLB36070A**15.211.77.88,400214125319
CAA**2517AM8(0,1)*SB36070M14***15.212.07.88,400214126146
CAA**2517AMPG80MS(A,L)A36070A**15.212.07.88,400214126147
CAA**2517AMPG80MS(A,L)A36070A**15.212.07.88,400214126148
CAA**2517AMPG80MS(A,L)A36070A**15.212.07.88,400214126149
CAA**2517AM8(0,1)*SB36070M17***15.212.07.88,400214126178
CAA**2517AMPG80MS(A,L)A36070B**15.212.07.88,400214126180
CAA**2517AMPG80MS(A,L)A36070B**15.212.07.88,400214126179
CAA**2517AMPG80MS(A,L)A36070B**15.212.07.88,400214126181
Yearly running cost in 10 large cities$547-$1,347

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Bryant PH5SAN518**AA?
The Bryant PH5SAN518**AA is rated at up to 15.5 SEER2 and 12.5 EER2 for cooling and up to 8.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 163 certified matchups SEER2 ranges from 15.2-15.5.
Is the Bryant PH5SAN518**AA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 1.5-ton model.
How much does the Bryant PH5SAN518**AA cost to run per year?
At its rated efficiency it costs about $547-$1,347 a year in electricity in large U.S. cities, depending on climate and local rates - for example $658 in Phoenix and $1,113 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Bryant PH5SAN518**AA?
ENERGY STAR lists 163 certified combinations for this outdoor unit. The highest-rated ones use FMA5X24**AL, CVAMA3217XMA, FM(C,U)5Z18**AL.
What refrigerant does the Bryant PH5SAN518**AA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $645/yrYou save $266/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Bryant PH5SAN518**AA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$645
Current system, per year
$910
You save per year
$266
Payback
26.4 years
Net after 10 years
-$4,345

Cooling $411Heating $234Electricity used: 4,030 kWhSaved vs. a minimum-efficiency heat pump: $50

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 1.5 ton models

See all 170 1.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 16, 2026. How we use the data.