HVAC Rated

1.5-ton central heat pump · LX SERIES

York YH618E2S11

Below average cooling and heating efficiency for a 1.5-ton central heat pump, but not rated for cold climates.

Ranks #135 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $552 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.0 Heating efficiency over a season
Below average · beats 12%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
9,100 BTU/h53% of its 47°F output
Excellent · beats 92%

A good fit if…

  • You want a choice of indoor units - 288 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications1.5 ton, R-454B
General
BrandYork
Outdoor unit modelYH618E2S11
SeriesLX SERIES
TypeCentral heat pump
Nominal size1.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceApril 24, 2026
Last certifiedJuly 15, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors12.0-12.5
Cooling capacity17,000-18,300 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.0
Capacity at 47°F16,100-17,000 BTU/h
Capacity at 17°F10,700-11,300 BTU/h
Capacity at 5°F8,700-9,100 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.26-2.34
ENERGY STAR cold climateNo
Heating output as it gets colder53% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CTM30B5ACS1 at the standard test temperatures, in BTU/h:

Certified matchups288 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 288 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CTM30B5ACS1Y82V080B12SMPC116.012.08.08,900218416925
CTF24B5ABS1+JME08B2SN1-16.012.58.08,800218416923
CTM30B5ACS1+JME12B2SN1-16.012.58.08,900218416922
CTM24B5ABS1Y82V080B12SMPC116.012.08.08,900218416906
CTU30B5XCS1+TXVY82V080B12SMPC116.012.08.08,900218416902
CTF30B5ACS1Y82V080B12SMPC116.012.08.08,900218416901
CTF24B5ABS1Y82V080B12SMPC116.012.08.08,900218416900
CTF24B5ABS1+JMET08BS2N1-16.012.58.08,900218416899
CTF24B5ABS1+JMET12BS2N1-16.012.58.08,800218416897
CTF24B5ABS1+JME12B2SN1-16.012.58.08,800218416896
CTU30B5XCS1+JME08B2SN1+TXV-16.012.58.08,900218416895
CTF30B5ACS1+JME08B2SN1-16.012.58.08,900218416894
CTU30B5XCS1+JMET08BS2N1+TXV-16.012.58.09,000218416893
CTF30B5ACS1+JMET08BS2N1-16.012.58.09,000218416892
CTM24B5ABS1+JME12B2SN1-16.012.58.08,800218416891
CTM30B5ACS1+JMC12B2SN1-16.012.58.09,000218416890
CTU30B5XCS1+JMC12B2SN1+TXV-16.012.58.08,900218416889
CTF30B5ACS1+JMC12B2SN1-16.012.58.08,900218416888
CTM24B5ABS1+JME08B2SN1-16.012.58.08,800218416886
CTM30B5ACS1+JME08B2SN1-16.012.58.08,900218416885
CTU30B5XCS1+JME12B2SN1+TXV-16.012.58.08,900218416882
CTF30B5ACS1+JME12B2SN1-16.012.58.08,900218416881
CTU30B5XCS1+JMET12BS2N1+TXV-16.012.58.08,900218416880
CTF30B5ACS1+JMET12BS2N1-16.012.58.08,900218416879
CTM30B5ACS1+JMET08BS2N1-16.012.58.08,900218416878
JHC18B5AB2SS1-16.012.58.08,900218416783
JHC24B5AC2SS1-16.012.58.08,900218416772
JHE18B5AB2SS1-16.012.58.08,800218416716
JHE24B5AC2SS1-16.012.58.08,900218416664
CTM30B5ACS2+JMC12B2SN1-16.012.58.09,000218509673
CTM30B5ACS2Y82V080B12SMPC116.012.08.08,900218509671
CTM24B5ABS2Y82V080B12SMPC116.012.08.08,900218509668
CTU30B5XCS2+TXVY82V080B12SMPC116.012.08.08,900218509478
CTF30B5ACS2Y82V080B12SMPC116.012.08.08,900218509476
CTU30B5XCS2+JMC12B2SN1+TXV-16.012.58.08,900218509473
CTF30B5ACS2+JMC12B2SN1-16.012.58.08,900218509471
CTF24B5ABS2Y82V080B12SMPC116.012.08.08,900218509403
CTF24B5ABS2+JME12B2SN2-16.012.58.08,800218636846
CTF24B5ABS2+JME08B2SN2-16.012.58.08,900218636845
CTM30B5ACS2+JME08B2SN2-16.012.58.08,900218636844
CTU30B5XCS2+JME08B2SN2+TXV-16.012.58.09,000218636842
CTF30B5ACS2+JME08B2SN2-16.012.58.09,000218636841
CTU30B5XCS2+JME12B2SN2+TXV-16.012.58.08,900218636838
CTF30B5ACS2+JME12B2SN2-16.012.58.08,900218636837
CTM24B5ABS1+JMET12BS2N1-15.212.57.88,800218416924
CTU24A5XBS1+TXVY82E060A12LMPS115.212.57.88,800218416917
CTF24A5ABS1Y82E060A12LMPS115.212.57.88,800218416916
CTM30B5ACS1TM8Y080B12MP1115.212.57.88,900218416909
CTU30B5XCS1+TXVY82E080B12LMPS115.212.57.88,800218416908
CTF30B5ACS1Y82E080B12LMPS115.212.57.88,800218416907
CTM24B5ABS1+JMC12B2SN1-15.212.57.88,900218416905
CTU24A5XBS1+TXVY82V060A12SMPC115.212.07.88,900218416904
CTF24A5ABS1Y82V060A12SMPC115.212.07.88,900218416903
CTM24A5ABS1Y82V060A12SMPC115.212.07.88,900218416898
CTF24B5ABS1+JMC12B2SN1-15.212.57.88,900218416887
CTM24B5ABS1+JMET08BS2N1-15.212.57.88,900218416884
CTM30B5ACS1+JMET12BS2N1-15.212.57.88,800218416883
CTU24A5XBS1+TXVTMLE040A12MP1115.212.57.89,000218416873
CTU24A5XBS1+TXVTM8E040A12MP1115.212.57.89,000218416872
CTF24A5ABS1TMLE040A12MP1115.212.57.89,000218416871
Yearly running cost in 10 large cities$499-$1,315

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the York YH618E2S11?
The York YH618E2S11 is rated at up to 16.0 SEER2 and 12.0 EER2 for cooling and up to 8.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 288 certified matchups SEER2 ranges from 15.2-16.0.
Is the York YH618E2S11 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 1.5-ton model.
How much does the York YH618E2S11 cost to run per year?
At its rated efficiency it costs about $499-$1,315 a year in electricity in large U.S. cities, depending on climate and local rates - for example $613 in Phoenix and $1,097 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the York YH618E2S11?
ENERGY STAR lists 288 certified combinations for this outdoor unit. The highest-rated ones use CTM30B5ACS1, CTF24B5ABS1+JME08B2SN1, CTM30B5ACS1+JME12B2SN1.
What refrigerant does the York YH618E2S11 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $606/yrYou save $264/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump York YH618E2S11
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$606
Current system, per year
$870
You save per year
$264
Payback
24.7 years
Net after 10 years
-$3,864

Cooling $374Heating $232Electricity used: 3,790 kWhSaved vs. a minimum-efficiency heat pump: $60

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 1.5 ton models

See all 170 1.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 15, 2026. How we use the data.