HVAC Rated

1.5-ton central heat pump · PERFORMANCE 16 SEER2 HP

Carrier 27SPA619A**30

Below average cooling and heating efficiency for a 1.5-ton central heat pump, but not rated for cold climates.

Ranks #127 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $636 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.0 Heating efficiency over a season
Below average · beats 12%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
8,500 BTU/h43% of its 47°F output
Below average · beats 39%

A good fit if…

  • You want a choice of indoor units - 84 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications1.5 ton, R-454B
General
BrandCarrier
Also sold asBryant
Outdoor unit model27SPA619A**30
SeriesPERFORMANCE 16 SEER2 HP
TypeCentral heat pump
Nominal size1.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJuly 31, 2025
Last certifiedJune 29, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors12.5-13.0
Cooling capacity17,700-19,300 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.0
Capacity at 47°F18,400-19,500 BTU/h
Capacity at 17°F10,300-11,000 BTU/h
Capacity at 5°F7,900-8,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.90-2.00
ENERGY STAR cold climateNo
Heating output as it gets colder43% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FM(C,U)5Z30**AL at the standard test temperatures, in BTU/h:

Certified matchups84 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 84 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FM(C,U)5Z30**AL-16.013.08.08,100217687083
CAA**2517AM58S(B,C)*B045M14**1216.013.08.08,400217704912
CAA**2517AM59SU5B060M17**1616.012.58.08,400217705758
CAA**2517AM59TN6C080C17**1416.013.08.08,300217705829
CAA**1917AM59SC2E060M17**1416.013.08.08,400217702471
CAA**1917AM59SC2E080M17**1616.013.08.08,300217702496
CAA**2517AM58S(B,C)*B070M14**1216.013.08.08,300217704962
CAA**2517AM58S(B,C)*B070M17**1216.013.08.08,400217704989
CAA**2517AM58S(B,C)*B070M17**1616.013.08.08,400217705014
CAA**2517AM58S(B,C)*B090M17**1416.013.08.08,300217705041
CAA**2517AM58SP*B045V14**1216.013.08.08,400217705068
CAA**2517AM58SP*B070V14**1216.013.08.08,400217705088
CAA**2517AM58SP*B070V17**1616.013.08.08,400217705108
CAA**2517AM58SP*B090V17**1616.013.08.08,400217705128
CAA**2517AM58SU*B040M17**1216.013.08.08,300217705148
CAA**2517AM58SU*B060M17**1616.013.08.08,400217705175
CAA**2517AM58TN*B070C14**1216.013.08.08,400217705224
CAA**2517AM59MN7C080C17**1416.013.08.08,400217705396
CAA**2517AM58TP*B045V14**1216.013.08.08,400217705290
CAA**2517AM58TP*B070V14**1216.013.08.08,400217705315
CAA**2517AM58TP*B070V17**1616.013.08.08,400217705322
CAA**1917AM59TN6C080C17**1416.013.08.08,300217702869
CAA**2517AM58TP*B090V17**1616.013.08.08,400217705345
CAA**2517AM59SC2E080M17**1616.013.08.08,300217705495
CAA**2517AM59SC2E060M14**1216.013.08.08,300217705445
CAA**2517AM59SC2E060M17**1416.013.08.08,400217705468
CAA**2517AM58CU*B040C17**1216.013.07.88,300217704868
CAA**2517AM58CU*B060C17**1616.013.07.88,300217704890
CAA**1917AM58SU*B040M17**1216.013.07.88,300217702256
CAA**1917AM58SU*B060M17**1616.013.07.88,300217702281
CAA**1917AM58CU*B040C17**1216.013.07.88,300217702212
CAA**1917AM58CU*B060C17**1616.013.07.88,300217702234
CAA**2517AM59SP6B060V14**1215.513.08.08,400217705691
CAA**1917AM58TP*B070V17**1615.513.08.08,400217702306
CAA**1917AM58TP*B090V17**1615.513.08.08,300217702329
CAA**1917AM59MN7C060C17**1415.513.08.08,400217702356
CAA**1917AM59MN7C080C17**1415.513.08.08,300217702378
CAA**2517AM59SC6A060M14**1215.513.08.08,400217705601
CAA**2517AM59SC6A080M17**1615.513.08.08,500217705624
CAA**2517AM59SP6B060V17**1615.513.08.08,400217705711
CAA**1917AM59TP7A060V17**1615.513.08.08,400217703056
CAA**1917AM59TP7A080V17**1615.513.08.08,300217703079
CAA**1917AM59SC2E060M14**1215.513.08.08,300217702448
CAA**2517AM59TN6C060C17**1415.513.08.08,400217705807
CAA**2517AM58S(B,C)*B045M17**1415.513.08.08,400217704939
CAA**2517AM59TN7A060C17**1615.513.08.08,400217705851
CAA**2517AM59TN7A080C17**1615.513.08.08,400217705873
CAA**1917AM59SC6A060M14**1215.513.08.08,400217702598
CAA**2517AM59TP6C060V14**1215.513.08.08,400217705945
CAA**2517AM59TP6C060V17**1615.513.08.08,400217705968
CAA**2517AMGG96VTAB48060B**15.513.08.08,400217705969
CAA**2517AM59TP7A060V17**1615.513.08.08,400217705995
CAA**2517AMOVMAAB03609815.513.08.08,300217706042
CAA**1917AM59SC6A080M17**1615.513.08.08,400217702650
CAA**1917AM59SP6B060V17**1615.513.08.08,400217702735
CAA**1917AM59SP6B080V17**1615.513.08.08,300217702755
CAA**2517AM58TN*B045C17**1215.513.08.08,400217705202
CAA**2517AM58TN*B070C17**1615.513.08.08,400217705246
CAA**2517AM58TN*B090C17**1615.513.08.08,400217705268
CAA**2517AM59MN7C060C17**1415.513.08.08,400217705374
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Carrier 27SPA619A**30: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$561-$1,526

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Carrier 27SPA619A**30?
The Carrier 27SPA619A**30 is rated at up to 16.0 SEER2 and 13.0 EER2 for cooling and up to 8.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 84 certified matchups SEER2 ranges from 15.2-16.0.
Is the Carrier 27SPA619A**30 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 1.5-ton model.
How much does the Carrier 27SPA619A**30 cost to run per year?
At its rated efficiency it costs about $561-$1,526 a year in electricity in large U.S. cities, depending on climate and local rates - for example $695 in Phoenix and $1,277 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Carrier 27SPA619A**30 the same as the Bryant 246SAN019**AA?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Carrier 27SPA619A**30?
ENERGY STAR lists 84 certified combinations for this outdoor unit. The highest-rated ones use FM(C,U)5Z30**AL, CAA**2517AM, CAA**1917AM.
What refrigerant does the Carrier 27SPA619A**30 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $692/yrYou save $298/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Carrier 27SPA619A**30
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$692
Current system, per year
$990
You save per year
$298
Payback
23.5 years
Net after 10 years
-$4,020

Cooling $420Heating $272Electricity used: 4,324 kWhSaved vs. a minimum-efficiency heat pump: $68

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 1.5 ton models

See all 170 1.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 29, 2026. How we use the data.