HVAC Rated

2.5-ton central heat pump · LX SERIES

Coleman XH630E2S11

Average cooling efficiency and below average heating efficiency for a 2.5-ton central heat pump, but not rated for cold climates.

Ranks #88 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $945 a year to run in a mixed climate like Atlanta.

SEER2
17.0 Cooling efficiency over a season
Average · beats 49%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
16,400 BTU/h52% of its 47°F output
Excellent · beats 95%

A good fit if…

  • You want a choice of indoor units - 1,019 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications2.5 ton, R-454B
General
BrandColeman
Also sold asLuxaire, Fraser-Johnston, CHAMPION HEATING AND COOLING, Kenmore
Outdoor unit modelXH630E2S11
SeriesLX SERIES
TypeCentral heat pump
Nominal size2.5 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceApril 24, 2026
Last certifiedSeptember 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better17.0 (range 15.2-17.0)
EER2Efficiency at 95°F outdoors11.0-13.0
Cooling capacity28,400-31,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.0-8.1
Capacity at 47°F28,800-30,000 BTU/h
Capacity at 17°F18,800-20,200 BTU/h
Capacity at 5°F15,000-16,400 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.40
ENERGY STAR cold climateNo
Heating output as it gets colder52% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CTM36C5ADS1 at the standard test temperatures, in BTU/h:

Certified matchups1,019 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 1,019 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CTM36C5ADS1Z8ET080C16LMPS117.013.08.115,200218418326
CTM36C5ADS1Z8ET080C16LMPS117.013.08.115,200218418325
CTM36C5ADS1Z8ET080C16LMPS117.013.08.115,200218418324
CTM36C5ADS1Z8ET080C16LMPS117.013.08.115,200218418323
CTM36C5ADS1Z8ES100C16LMPS117.012.58.115,400218418314
CTM36C5ADS1Z8ES100C16LMPS117.012.58.115,400218418313
CTM36C5ADS1Z8ES100C16LMPS117.012.58.115,400218418312
CTM36C5ADS1Z8ES100C16LMPS117.012.58.115,400218418311
CTM36C5ADS1Z8ES100C16SMPS117.012.58.115,400218418310
CTM36C5ADS1Z8ES100C16SMPS117.012.58.115,400218418309
CTM36C5ADS1Z8ES100C16SMPS117.012.58.115,400218418308
CTM36C5ADS1Z8ES100C16SMPS117.012.58.115,400218418307
CTU36B5XDS1+TXVZ8ET080B12LMPS117.012.08.115,600218418212
CTU36B5XDS1+TXVZ8ET080B12LMPS117.012.08.115,600218418211
CTU36B5XDS1+TXVZ8ET080B12LMPS117.012.08.115,600218418210
CTU36B5XDS1+TXVZ8ET080B12LMPS117.012.08.115,600218418209
CTF36B5ADS1Z8ET080B12LMPS117.012.08.115,600218418208
CTF36B5ADS1Z8ET080B12LMPS117.012.08.115,600218418207
CTF36B5ADS1Z8ET080B12LMPS117.012.08.115,600218418206
CTF36B5ADS1Z8ET080B12LMPS117.012.08.115,600218418205
CTM36C5ADS1Z8ES080C16LMPS117.013.08.115,200218418046
CTM36C5ADS1Z8ES080C16LMPS117.013.08.115,200218418045
CTM36C5ADS1Z8ES080C16LMPS117.013.08.115,200218418044
CTM36C5ADS1Z8ES080C16LMPS117.013.08.115,200218418043
CTM36C5ADS1Z8ES080C16SMPS117.013.08.115,200218418042
CTM36C5ADS1Z8ES080C16SMPS117.013.08.115,200218418041
CTM36C5ADS1Z8ES080C16SMPS117.013.08.115,200218418040
CTM36C5ADS1Z8ES080C16SMPS117.013.08.115,200218418039
CTF36C5ADS1Z8ET080C16LMPS117.013.08.115,200218418038
CTF36C5ADS1Z8ET080C16LMPS117.013.08.115,200218418037
CTF36C5ADS1Z8ET080C16LMPS117.013.08.115,200218418036
CTF36C5ADS1Z8ET080C16LMPS117.013.08.115,200218418035
CTU36B5XDS1+TXVZ8ES080B12LMPS117.012.58.115,400218418032
CTU36B5XDS1+TXVZ8ES080B12LMPS117.012.58.115,400218418031
CTU36B5XDS1+TXVZ8ES080B12LMPS117.012.58.115,400218418030
CTU36B5XDS1+TXVZ8ES080B12LMPS117.012.58.115,400218418029
CTU36B5XDS1+TXVZ8ES080B12SMPS117.012.58.115,400218418028
CTU36B5XDS1+TXVZ8ES080B12SMPS117.012.58.115,400218418027
CTU36B5XDS1+TXVZ8ES080B12SMPS117.012.58.115,400218418026
CTU36B5XDS1+TXVZ8ES080B12SMPS117.012.58.115,400218418025
CTF36B5ADS1Z8ES080B12LMPS117.012.58.115,400218418022
CTF36B5ADS1Z8ES080B12LMPS117.012.58.115,400218418021
CTF36B5ADS1Z8ES080B12LMPS117.012.58.115,400218418020
CTF36B5ADS1Z8ES080B12LMPS117.012.58.115,400218418019
CTF36B5ADS1Z8ES080B12SMPS117.012.58.115,400218418018
CTF36B5ADS1Z8ES080B12SMPS117.012.58.115,400218418017
CTF36B5ADS1Z8ES080B12SMPS117.012.58.115,400218418016
CTF36B5ADS1Z8ES080B12SMPS117.012.58.115,400218418015
CTF36C5ADS1Z8ES100C16LMPS117.012.58.115,400218418012
CTF36C5ADS1Z8ES100C16LMPS117.012.58.115,400218418011
CTF36C5ADS1Z8ES100C16LMPS117.012.58.115,400218418010
CTF36C5ADS1Z8ES100C16LMPS117.012.58.115,400218418009
CTF36C5ADS1Z8ES100C16SMPS117.012.58.115,400218418008
CTF36C5ADS1Z8ES100C16SMPS117.012.58.115,400218418007
CTF36C5ADS1Z8ES100C16SMPS117.012.58.115,400218418006
CTF36C5ADS1Z8ES100C16SMPS117.012.58.115,400218418005
JHE36B5AD2SS1-17.012.58.115,400218418002
JHE36B5AD2SS1-17.012.58.115,400218418001
JHE36B5AD2SS1-17.012.58.115,400218418000
JHE36B5AD2SS1-17.012.58.115,400218417999
Yearly running cost in 10 large cities$825-$2,275

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Coleman XH630E2S11?
The Coleman XH630E2S11 is rated at up to 17.0 SEER2 and 13.0 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 1019 certified matchups SEER2 ranges from 15.2-17.0.
Is the Coleman XH630E2S11 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2.5-ton model.
How much does the Coleman XH630E2S11 cost to run per year?
At its rated efficiency it costs about $825-$2,275 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,026 in Phoenix and $1,909 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Coleman XH630E2S11?
ENERGY STAR lists 1019 certified combinations for this outdoor unit. The highest-rated ones use CTM36C5ADS1, CTU36B5XDS1+TXV, CTF36B5ADS1.
What refrigerant does the Coleman XH630E2S11 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,024/yrYou save $506/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Coleman XH630E2S11
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,024
Current system, per year
$1,530
You save per year
$506
Payback
21.7 years
Net after 10 years
-$5,935

Cooling $617Heating $407Electricity used: 6,397 kWhSaved vs. a minimum-efficiency heat pump: $149

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2.5 ton models

See all 199 2.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 16, 2026. How we use the data.