2.5-ton central heat pump · LX SERIES
Coleman XH630E2S11
Average cooling efficiency and below average heating efficiency for a 2.5-ton central heat pump, but not rated for cold climates.
Ranks #88 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $945 a year to run in a mixed climate like Atlanta.
- SEER2
- 17.0 Cooling efficiency over a seasonAverage · beats 49%
- HSPF2
- 8.1 Heating efficiency over a seasonBelow average · beats 20%
- EER2
- 13.0 Cooling efficiency on a 95°F dayVery good · beats 89%
- Heat at 5°F
- 16,400 BTU/h52% of its 47°F outputExcellent · beats 95%
A good fit if…
- You want a choice of indoor units - 1,019 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
Details
Specifications
| General | |
|---|---|
| Brand | Coleman |
| Also sold as | Luxaire, Fraser-Johnston, CHAMPION HEATING AND COOLING, Kenmore |
| Outdoor unit model | XH630E2S11 |
| Series | LX SERIES |
| Type | Central heat pump |
| Nominal size | 2.5 ton |
| CompressorVariable-speed units run longer at low power | Two-stage |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | April 24, 2026 |
| Last certified | September 16, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 17.0 (range 15.2-17.0) |
| EER2Efficiency at 95°F outdoors | 11.0-13.0 |
| Cooling capacity | 28,400-31,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.0-8.1 |
| Capacity at 47°F | 28,800-30,000 BTU/h |
| Capacity at 17°F | 18,800-20,200 BTU/h |
| Capacity at 5°F | 15,000-16,400 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00-2.40 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CTM36C5ADS1 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 1,019 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| CTM36C5ADS1 | Z8ET080C16LMPS1 | 17.0 | 13.0 | 8.1 | 15,200 | 218418326 |
| CTM36C5ADS1 | Z8ET080C16LMPS1 | 17.0 | 13.0 | 8.1 | 15,200 | 218418325 |
| CTM36C5ADS1 | Z8ET080C16LMPS1 | 17.0 | 13.0 | 8.1 | 15,200 | 218418324 |
| CTM36C5ADS1 | Z8ET080C16LMPS1 | 17.0 | 13.0 | 8.1 | 15,200 | 218418323 |
| CTM36C5ADS1 | Z8ES100C16LMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418314 |
| CTM36C5ADS1 | Z8ES100C16LMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418313 |
| CTM36C5ADS1 | Z8ES100C16LMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418312 |
| CTM36C5ADS1 | Z8ES100C16LMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418311 |
| CTM36C5ADS1 | Z8ES100C16SMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418310 |
| CTM36C5ADS1 | Z8ES100C16SMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418309 |
| CTM36C5ADS1 | Z8ES100C16SMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418308 |
| CTM36C5ADS1 | Z8ES100C16SMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418307 |
| CTU36B5XDS1+TXV | Z8ET080B12LMPS1 | 17.0 | 12.0 | 8.1 | 15,600 | 218418212 |
| CTU36B5XDS1+TXV | Z8ET080B12LMPS1 | 17.0 | 12.0 | 8.1 | 15,600 | 218418211 |
| CTU36B5XDS1+TXV | Z8ET080B12LMPS1 | 17.0 | 12.0 | 8.1 | 15,600 | 218418210 |
| CTU36B5XDS1+TXV | Z8ET080B12LMPS1 | 17.0 | 12.0 | 8.1 | 15,600 | 218418209 |
| CTF36B5ADS1 | Z8ET080B12LMPS1 | 17.0 | 12.0 | 8.1 | 15,600 | 218418208 |
| CTF36B5ADS1 | Z8ET080B12LMPS1 | 17.0 | 12.0 | 8.1 | 15,600 | 218418207 |
| CTF36B5ADS1 | Z8ET080B12LMPS1 | 17.0 | 12.0 | 8.1 | 15,600 | 218418206 |
| CTF36B5ADS1 | Z8ET080B12LMPS1 | 17.0 | 12.0 | 8.1 | 15,600 | 218418205 |
| CTM36C5ADS1 | Z8ES080C16LMPS1 | 17.0 | 13.0 | 8.1 | 15,200 | 218418046 |
| CTM36C5ADS1 | Z8ES080C16LMPS1 | 17.0 | 13.0 | 8.1 | 15,200 | 218418045 |
| CTM36C5ADS1 | Z8ES080C16LMPS1 | 17.0 | 13.0 | 8.1 | 15,200 | 218418044 |
| CTM36C5ADS1 | Z8ES080C16LMPS1 | 17.0 | 13.0 | 8.1 | 15,200 | 218418043 |
| CTM36C5ADS1 | Z8ES080C16SMPS1 | 17.0 | 13.0 | 8.1 | 15,200 | 218418042 |
| CTM36C5ADS1 | Z8ES080C16SMPS1 | 17.0 | 13.0 | 8.1 | 15,200 | 218418041 |
| CTM36C5ADS1 | Z8ES080C16SMPS1 | 17.0 | 13.0 | 8.1 | 15,200 | 218418040 |
| CTM36C5ADS1 | Z8ES080C16SMPS1 | 17.0 | 13.0 | 8.1 | 15,200 | 218418039 |
| CTF36C5ADS1 | Z8ET080C16LMPS1 | 17.0 | 13.0 | 8.1 | 15,200 | 218418038 |
| CTF36C5ADS1 | Z8ET080C16LMPS1 | 17.0 | 13.0 | 8.1 | 15,200 | 218418037 |
| CTF36C5ADS1 | Z8ET080C16LMPS1 | 17.0 | 13.0 | 8.1 | 15,200 | 218418036 |
| CTF36C5ADS1 | Z8ET080C16LMPS1 | 17.0 | 13.0 | 8.1 | 15,200 | 218418035 |
| CTU36B5XDS1+TXV | Z8ES080B12LMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418032 |
| CTU36B5XDS1+TXV | Z8ES080B12LMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418031 |
| CTU36B5XDS1+TXV | Z8ES080B12LMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418030 |
| CTU36B5XDS1+TXV | Z8ES080B12LMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418029 |
| CTU36B5XDS1+TXV | Z8ES080B12SMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418028 |
| CTU36B5XDS1+TXV | Z8ES080B12SMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418027 |
| CTU36B5XDS1+TXV | Z8ES080B12SMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418026 |
| CTU36B5XDS1+TXV | Z8ES080B12SMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418025 |
| CTF36B5ADS1 | Z8ES080B12LMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418022 |
| CTF36B5ADS1 | Z8ES080B12LMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418021 |
| CTF36B5ADS1 | Z8ES080B12LMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418020 |
| CTF36B5ADS1 | Z8ES080B12LMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418019 |
| CTF36B5ADS1 | Z8ES080B12SMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418018 |
| CTF36B5ADS1 | Z8ES080B12SMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418017 |
| CTF36B5ADS1 | Z8ES080B12SMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418016 |
| CTF36B5ADS1 | Z8ES080B12SMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418015 |
| CTF36C5ADS1 | Z8ES100C16LMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418012 |
| CTF36C5ADS1 | Z8ES100C16LMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418011 |
| CTF36C5ADS1 | Z8ES100C16LMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418010 |
| CTF36C5ADS1 | Z8ES100C16LMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418009 |
| CTF36C5ADS1 | Z8ES100C16SMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418008 |
| CTF36C5ADS1 | Z8ES100C16SMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418007 |
| CTF36C5ADS1 | Z8ES100C16SMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418006 |
| CTF36C5ADS1 | Z8ES100C16SMPS1 | 17.0 | 12.5 | 8.1 | 15,400 | 218418005 |
| JHE36B5AD2SS1 | - | 17.0 | 12.5 | 8.1 | 15,400 | 218418002 |
| JHE36B5AD2SS1 | - | 17.0 | 12.5 | 8.1 | 15,400 | 218418001 |
| JHE36B5AD2SS1 | - | 17.0 | 12.5 | 8.1 | 15,400 | 218418000 |
| JHE36B5AD2SS1 | - | 17.0 | 12.5 | 8.1 | 15,400 | 218417999 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,026/yr
- Miami, FL$825/yr
- Houston, TX$920/yr
- Atlanta, GA$945/yr
- Los Angeles, CA$923/yr
- New York, NY$2,275/yr
- Chicago, IL$1,851/yr
- Denver, CO$1,541/yr
- Seattle, WA$949/yr
- Minneapolis, MN$1,909/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Coleman XH630E2S11?
- The Coleman XH630E2S11 is rated at up to 17.0 SEER2 and 13.0 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 1019 certified matchups SEER2 ranges from 15.2-17.0.
- Is the Coleman XH630E2S11 good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2.5-ton model.
- How much does the Coleman XH630E2S11 cost to run per year?
- At its rated efficiency it costs about $825-$2,275 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,026 in Phoenix and $1,909 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Coleman XH630E2S11?
- ENERGY STAR lists 1019 certified combinations for this outdoor unit. The highest-rated ones use CTM36C5ADS1, CTU36B5XDS1+TXV, CTF36B5ADS1.
- What refrigerant does the Coleman XH630E2S11 use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2.5 ton models
- Heil D5CUHAH30AAK+TIC2025-0016 · cold climate17.0 SEER2 · 8.5 HSPF2
- Guardian RH630E2S1117.0 SEER2 · 8.1 HSPF2
- Carrier 37MUHAQ30AA3+TIC2025-0016 · cold climate17.0 SEER2 · 8.5 HSPF2
- York YH630E2S1117.0 SEER2 · 8.1 HSPF2
- Carrier 37MUHAQ30AA3+KSAIC0701230 · cold climate17.0 SEER2 · 9.0 HSPF2
- Breeze33 BZ33-INV30OUT2-J · cold climate16.9 SEER2 · 9.7 HSPF2
- Airquest D5CUHAH30AAK+KSAIC0701230 · cold climate17.0 SEER2 · 9.0 HSPF2
- Capella CCB1-H30A-O · cold climate16.8 SEER2 · 10.0 HSPF2
See all 199 2.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 16, 2026. How we use the data.