HVAC Rated

2.5-ton central heat pump · Crossover Heat Pump

Carrier 37MUHAQ30AA3+KSAIC0701230

Average cooling and heating efficiency for a 2.5-ton central heat pump, and certified for cold climates.

Ranks #85 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $1,014 a year to run in a mixed climate like Atlanta.

SEER2
17.0 Cooling efficiency over a season
Average · beats 49%
HSPF2
9.0 Heating efficiency over a season
Average · beats 54%
EER2
10.0 Cooling efficiency on a 95°F day
Below average · beats 10%
Heat at 5°F
33,400 BTU/h89% of its 47°F output
Below average · beats 39%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 33,400 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 1,214 certified pairings.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications2.5 ton, R-454B
General
BrandCarrier
Also sold asBryant, PAYNE HEATING AND COOLING, WeatherMaker
Outdoor unit model37MUHAQ30AA3+KSAIC0701230
SeriesCrossover Heat Pump
TypeCentral heat pump
Nominal size2.5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceMay 6, 2025
Last certifiedOctober 7, 2026
Cooling
SEER2Seasonal efficiency, higher is better17.0 (range 15.2-17.0)
EER2Efficiency at 95°F outdoors9.5-10.5
Cooling capacity28,600-31,200 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1-9.0
Capacity at 47°F35,800-37,400 BTU/h
Capacity at 17°F20,800-21,600 BTU/h
Capacity at 5°F32,000-33,400 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.75-2.00
ENERGY STAR cold climateYes
Heating output as it gets colder89% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CAA**3721AM at the standard test temperatures, in BTU/h:

Certified matchups1,214 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 1,214 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CAA**3721AM · cold climate58SU*B080M21**2017.010.09.032,000218474148
CAA**4321AM · cold climate58SU*B080M21**2017.010.09.032,000218474038
CAA**3721AM · cold climatePG80MSUA60080C**17.010.09.032,000218478629
CAA**3721AM · cold climate83*SB60080M21***17.010.09.032,000218478627
CAA**4321AM · cold climatePG80MSUA60080C**17.010.09.032,000218478254
CAA**4321AM · cold climate83*SB60080M21***17.010.09.032,000218478252
CAA**3721AM · cold climatePG80MSUA60080C**17.010.09.032,000218815658
CAA**4321AM · cold climatePG80MSUA60080C**17.010.09.032,000218815584
FT5AN(B,X)C36L · cold climate-17.010.08.532,800218473012
FT5AN(B,X)C36L · cold climate-17.010.08.532,800218475376
PF5TNXC36L · cold climate-17.010.08.532,800218475375
FG5ANXC36L · cold climate-17.010.08.532,800218477454
FG5ANXC36L · cold climate-17.010.08.532,800218477453
PF5TNXC36L · cold climate-17.010.08.532,800218477406
CAA**3721AM · cold climate59TP7A100V21**2216.510.09.032,200218474184
CAA**3721AM · cold climate59TP7A100V21**2016.510.09.032,200218474183
CAA**3721AM · cold climate59TP7A080V21**2016.510.09.032,200218474182
CAA**3721AM · cold climate59TP6C100V21**2216.510.09.032,200218474179
CAA**3721AM · cold climate59TP6C100V21**2016.510.09.032,200218474178
CAA**3721AM · cold climate59TP6C080V21**2016.510.09.032,200218474177
CAA**3721AM · cold climate59SU5B100M21**2216.510.09.032,200218474173
CAA**3721AM · cold climate59SU5B100M21**2016.510.09.032,200218474172
CAA**3721AM · cold climate59SP6B100V21**2016.510.09.032,200218474168
CAA**3721AM · cold climate59SP6B080V21**2016.510.09.032,200218474167
CAA**3721AM · cold climate58TP*B110V21**2216.510.09.032,200218474153
CAA**3721AM · cold climate58TP*B090V17**1616.510.09.032,200218474151
CAA**3721AM · cold climate58TP*B070V17**1616.510.09.032,200218474150
CAA**3721AM · cold climate58SU*B060M17**1616.510.09.032,200218474147
CAA**3721AM · cold climate58SU*B040M17**1216.510.09.032,200218474146
CAA**3721AM · cold climate58SP*B110V21**2216.510.09.032,200218474145
CAA**3721AM · cold climate58SP*B090V17**1616.510.09.032,200218474143
CAA**4321AM · cold climate59TP7A100V21**2216.510.09.032,200218474074
CAA**4321AM · cold climate59TP7A100V21**2016.510.09.032,200218474073
CAA**4321AM · cold climate59TP7A080V21**2016.510.09.032,200218474072
CAA**4321AM · cold climate59TP6C100V21**2216.510.09.032,200218474069
CAA**4321AM · cold climate59TP6C100V21**2016.510.09.032,200218474068
CAA**4321AM · cold climate59TP6C080V21**2016.510.09.032,200218474067
CAA**4321AM · cold climate59SU5B100M21**2216.510.09.032,200218474063
CAA**4321AM · cold climate59SU5B100M21**2016.510.09.032,200218474062
CAA**4321AM · cold climate59SP6B100V21**2016.510.09.032,200218474058
CAA**4321AM · cold climate59SP6B080V21**2016.510.09.032,200218474057
CAA**4321AM · cold climate58TP*B110V21**2216.510.09.032,200218474043
CAA**4321AM · cold climate58TP*B090V17**1616.510.09.032,200218474041
CAA**4321AM · cold climate58TP*B070V17**1616.510.09.032,200218474040
CAA**4321AM · cold climate58SU*B060M17**1616.510.09.032,200218474037
CAA**4321AM · cold climate58SU*B040M17**1216.510.09.032,200218474036
CAA**4321AM · cold climate58SP*B110V21**2216.510.09.032,200218474035
CAA**4321AM · cold climate58SP*B090V17**1616.510.09.032,200218474033
FMA5X30**AL · cold climate-16.510.59.032,000218473798
FMA5X36**AL · cold climate-16.510.59.032,000218473797
CAA**3721AM · cold climate927TA66100V21***16.510.09.032,200218478754
CAA**3721AM · cold climatePG97VTAA60100C**16.510.09.032,200218478752
CAA**3721AM · cold climate927TA60100V21***16.510.09.032,200218478750
CAA**3721AM · cold climatePG97VTAA60080C**16.510.09.032,200218478748
CAA**3721AM · cold climate927TA60080V21***16.510.09.032,200218478745
CAA**3721AM · cold climate926TC66100V21***16.510.09.032,200218478737
CAA**3721AM · cold climatePG96VTAB60100C**16.510.09.032,200218478735
CAA**3721AM · cold climate926TC60100V21***16.510.09.032,200218478733
CAA**3721AM · cold climateGG96VTAB60100C**16.510.09.032,200218478731
CAA**3721AM · cold climatePG96VTAB60080C**16.510.09.032,200218478730
Yearly running cost in 10 large cities$828-$2,487

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Carrier 37MUHAQ30AA3+KSAIC0701230?
The Carrier 37MUHAQ30AA3+KSAIC0701230 is rated at up to 17.0 SEER2 and 10.0 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 1214 certified matchups SEER2 ranges from 15.2-17.0.
Is the Carrier 37MUHAQ30AA3+KSAIC0701230 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 33,400 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Carrier 37MUHAQ30AA3+KSAIC0701230 cost to run per year?
At its rated efficiency it costs about $828-$2,487 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,059 in Phoenix and $2,107 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Carrier 37MUHAQ30AA3+KSAIC0701230?
ENERGY STAR lists 1214 certified combinations for this outdoor unit. The highest-rated ones use CAA**3721AM, CAA**4321AM, FT5AN(B,X)C36L.
What refrigerant does the Carrier 37MUHAQ30AA3+KSAIC0701230 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,070/yrYou save $575/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Carrier 37MUHAQ30AA3+KSAIC0701230
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,070
Current system, per year
$1,645
You save per year
$575
Payback
19.1 years
Net after 10 years
-$5,255

Cooling $617Heating $453Electricity used: 6,688 kWhSaved vs. a minimum-efficiency heat pump: $207

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2.5 ton models

See all 199 2.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 7, 2026. How we use the data.