2.5-ton central heat pump · UHP Series
MRCOOL UHP18030-O
Average cooling efficiency and excellent heating efficiency for a 2.5-ton central heat pump, and certified for cold climates.
Ranks #79 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $806 a year to run in a mixed climate like Atlanta.
- SEER2
- 17.2 Cooling efficiency over a seasonAverage · beats 54%
- HSPF2
- 10.8 Heating efficiency over a seasonExcellent · beats 98%
- EER2
- 12.0 Cooling efficiency on a 95°F dayAverage · beats 64%
- Heat at 5°F
- 33,200 BTU/h101% of its 47°F outputBelow average · beats 30%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 33,200 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 98% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | MRCOOL |
| Outdoor unit model | UHP18030-O |
| Series | UHP Series |
| Type | Central heat pump |
| Nominal size | 2.5 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | August 15, 2025 |
| Last certified | January 20, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 17.2 (range 15.6-17.2) |
| EER2Efficiency at 95°F outdoors | 10.7-12.0 |
| Cooling capacity | 29,000-30,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.7-10.8 |
| Capacity at 47°F | 31,000-33,000 BTU/h |
| Capacity at 17°F | 22,000-24,000 BTU/h |
| Capacity at 5°F | 28,000-33,200 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.75-1.97 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with UAH18030 - O at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| UAH18030 - O · cold climate | - | 17.2 | 12.0 | 10.8 | 33,200 | 217730329 |
| **AECMPT36D2AA · cold climate | MGM96EE080C4NB | 15.8 | 11.0 | 9.0 | 29,000 | 218029377 |
| **AECMPT36B2AA · cold climate | MGM96EE060B3NB | 15.8 | 10.8 | 8.7 | 28,000 | 218029375 |
| MCMP3036BOTB · cold climate | MGM96EE060B3NB | 15.8 | 10.8 | 8.7 | 28,000 | 218029363 |
| **AECMPT36B2AA · cold climate | MGM96EE080B3NB | 15.6 | 10.7 | 8.8 | 29,000 | 218029376 |
| MCMP3036BOTB · cold climate | MGM96EE080B3NB | 15.6 | 10.7 | 8.8 | 29,000 | 218029364 |
Yearly running cost in 10 large cities
- Phoenix, AZ$939/yr
- Miami, FL$789/yr
- Houston, TX$841/yr
- Atlanta, GA$806/yr
- Los Angeles, CA$774/yr
- New York, NY$1,872/yr
- Chicago, IL$1,509/yr
- Denver, CO$1,246/yr
- Seattle, WA$759/yr
- Minneapolis, MN$1,538/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the MRCOOL UHP18030-O?
- The MRCOOL UHP18030-O is rated at up to 17.2 SEER2 and 12.0 EER2 for cooling and up to 10.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 6 certified matchups SEER2 ranges from 15.6-17.2.
- Is the MRCOOL UHP18030-O good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 33,200 BTU/h at 5°F with a COP of 1.97, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the MRCOOL UHP18030-O cost to run per year?
- At its rated efficiency it costs about $759-$1,872 a year in electricity in large U.S. cities, depending on climate and local rates - for example $939 in Phoenix and $1,538 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the MRCOOL UHP18030-O?
- ENERGY STAR lists 6 certified combinations for this outdoor unit. The highest-rated ones use UAH18030 - O, **AECMPT36D2AA, **AECMPT36B2AA.
- What refrigerant does the MRCOOL UHP18030-O use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2.5 ton models
- Breeze33 BZ33-INV30OUT2-454-G3-J · cold climate17.2 SEER2 · 10.8 HSPF2
- NOVAIR LEA30CEN36-O · cold climate17.2 SEER2 · 10.8 HSPF2
- Blueridge BNG3A30UCN · cold climate17.2 SEER2 · 10.8 HSPF2
- Thermal Zone TZID30H520ZCS17.1 SEER2 · 8.4 HSPF2
- Blueridge BMSAH30HHC · cold climate17.2 SEER2 · 10.8 HSPF2
- Panasonic CU-M30BAHU17.1 SEER2 · 8.3 HSPF2
- AproDr AHU3G-30HFN-B · cold climate17.2 SEER2 · 10.8 HSPF2
- TCL H30TDHXPC · cold climate17.0 SEER2 · 9.5 HSPF2
See all 199 2.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of January 20, 2026. How we use the data.