30,000 BTU mini-split heat pump · A-VHP Series
Comfort-Aire A-VHP284A-1
Average cooling and heating efficiency for a 30,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #41 of 171 30,000 BTU mini-splits for cooling efficiency, and costs about $666 a year to run in a mixed climate like Atlanta.
- SEER2
- 23.0 Cooling efficiency over a seasonAverage · beats 62%
- HSPF2
- 10.5 Heating efficiency over a seasonAverage · beats 61%
- EER2
- 12.5 Cooling efficiency on a 95°F dayAverage · beats 44%
- Heat at 5°F
- 27,000 BTU/h100% of its 47°F outputAverage · beats 48%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 27,000 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Comfort-Aire |
| Also sold as | Century |
| Outdoor unit model | A-VHP284A-1 |
| Series | A-VHP Series |
| Type | Mini-split heat pump |
| Nominal size | 30,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | November 11, 2024 |
| Last certified | May 28, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 23.0 (range 19.0-23.0) |
| EER2Efficiency at 95°F outdoors | 12.0-12.5 |
| Cooling capacity | 27,000-28,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.5-10.5 |
| Capacity at 47°F | 27,000-28,000 BTU/h |
| Capacity at 17°F | 24,000-30,000 BTU/h |
| Capacity at 5°F | 27,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| - COMFORT-AIRE · cold climate | 23.0 | 12.5 | 10.5 | 27,000 | 216097127 |
| - Comfort Aire · cold climate | 23.0 | 12.5 | 10.5 | 27,000 | 217101914 |
| - CENTURY · cold climate | 23.0 | 12.5 | 10.5 | 27,000 | 218425162 |
| - COMFORT-AIRE · cold climate | 21.0 | 12.3 | 10.0 | 27,000 | 216097129 |
| - Comfort Aire · cold climate | 21.0 | 12.3 | 10.0 | 27,000 | 217101916 |
| - CENTURY · cold climate | 21.0 | 12.3 | 10.0 | 27,000 | 218425164 |
| - COMFORT-AIRE · cold climate | 19.0 | 12.0 | 9.5 | 27,000 | 216097128 |
| - Comfort Aire · cold climate | 19.0 | 12.0 | 9.5 | 27,000 | 217101915 |
| - CENTURY · cold climate | 19.0 | 12.0 | 9.5 | 27,000 | 218425163 |
Yearly running cost in 10 large cities
- Phoenix, AZ$709/yr
- Miami, FL$562/yr
- Houston, TX$636/yr
- Atlanta, GA$666/yr
- Los Angeles, CA$653/yr
- New York, NY$1,619/yr
- Chicago, IL$1,320/yr
- Denver, CO$1,102/yr
- Seattle, WA$680/yr
- Minneapolis, MN$1,365/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Comfort-Aire A-VHP284A-1?
- The Comfort-Aire A-VHP284A-1 is rated at up to 23.0 SEER2 and 12.5 EER2 for cooling and up to 10.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 9 certified matchups SEER2 ranges from 19.0-23.0.
- Is the Comfort-Aire A-VHP284A-1 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 27,000 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the Comfort-Aire A-VHP284A-1 cost to run per year?
- At its rated efficiency it costs about $562-$1,619 a year in electricity in large U.S. cities, depending on climate and local rates - for example $709 in Phoenix and $1,365 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- What refrigerant does the Comfort-Aire A-VHP284A-1 use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 30,000 BTU models
- Bosch BMS500-AAM027-1CSXHD · cold climate23.0 SEER2 · 10.5 HSPF2
- MDV M4OD31-27HFN10-M1X-D · cold climate23.0 SEER2 · 10.5 HSPF2
- MDV M3OI-28HFN1-M · cold climate23.0 SEER2 · 10.6 HSPF2
- AUX AM4-H30/2DR3A · cold climate23.0 SEER2 · 10.0 HSPF2
- Lennox MLB030S4M-1P · cold climate23.0 SEER2 · 10.6 HSPF2
- AUX ASPR30HPMULO · cold climate23.0 SEER2 · 10.0 HSPF2
- Kepler ODUM3OK-27HFN1-M · cold climate23.0 SEER2 · 10.6 HSPF2
- NG Trade MOSA32301 · cold climate23.0 SEER2 · 10.0 HSPF2
See all 171 30,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 28, 2026. How we use the data.