24,000 BTU mini-split heat pump · A-series
Comfort-Aire A-VMH24SU-1A
Below average cooling efficiency and average heating efficiency for a 24,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #392 of 430 24,000 BTU mini-splits for cooling efficiency, and costs about $597 a year to run in a mixed climate like Atlanta.
- SEER2
- 18.9 Cooling efficiency over a seasonBelow average · beats 8%
- HSPF2
- 10.4 Heating efficiency over a seasonAverage · beats 57%
- EER2
- 11.7 Cooling efficiency on a 95°F dayBelow average · beats 16%
- Heat at 5°F
- 23,400 BTU/h100% of its 47°F outputBelow average · beats 22%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 23,400 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Cooling cost matters most - its SEER2 is below average for mini-splits.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Comfort-Aire |
| Outdoor unit model | A-VMH24SU-1A |
| Series | A-series |
| Type | Mini-split heat pump |
| Nominal size | 24,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | December 18, 2019 |
| Last certified | June 13, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 18.9 (range 18.9) |
| EER2Efficiency at 95°F outdoors | 11.7 |
| Cooling capacity | 21,600 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 10.4 |
| Capacity at 47°F | 23,400 BTU/h |
| Capacity at 17°F | 19,400 BTU/h |
| Capacity at 5°F | 23,400 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.89 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with B-VMH24SU-1A at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| B-VMH24SU-1A COMFORT-AIRE · cold climate | 18.9 | 11.7 | 10.4 | 23,400 | 206221394 |
| B-VMH24SU-1 COMFORT-AIRE · cold climate | 18.9 | 11.7 | 10.4 | 23,400 | 206913036 |
| B-VMH24SU-1A Comfort Aire · cold climate | 18.9 | 11.7 | 10.4 | 23,400 | 217101827 |
| B-VMH24SU-1 Comfort Aire · cold climate | 18.9 | 11.7 | 10.4 | 23,400 | 217101829 |
Yearly running cost in 10 large cities
- Phoenix, AZ$660/yr
- Miami, FL$537/yr
- Houston, TX$592/yr
- Atlanta, GA$597/yr
- Los Angeles, CA$580/yr
- New York, NY$1,424/yr
- Chicago, IL$1,156/yr
- Denver, CO$960/yr
- Seattle, WA$590/yr
- Minneapolis, MN$1,189/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Comfort-Aire A-VMH24SU-1A?
- The Comfort-Aire A-VMH24SU-1A is rated at up to 18.9 SEER2 and 11.7 EER2 for cooling and up to 10.4 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the Comfort-Aire A-VMH24SU-1A good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 23,400 BTU/h at 5°F with a COP of 1.89, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
- How much does the Comfort-Aire A-VMH24SU-1A cost to run per year?
- At its rated efficiency it costs about $537-$1,424 a year in electricity in large U.S. cities, depending on climate and local rates - for example $660 in Phoenix and $1,189 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Comfort-Aire A-VMH24SU-1A?
- ENERGY STAR lists 4 certified combinations for this outdoor unit. The highest-rated ones use COMFORT-AIRE B-VMH24SU-1A, COMFORT-AIRE B-VMH24SU-1, Comfort Aire B-VMH24SU-1A.
- What refrigerant does the Comfort-Aire A-VMH24SU-1A use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 24,000 BTU models
- CanAir C23SCH24H22 · cold climate18.9 SEER2 · 10.4 HSPF2
- Lennox VPC024H4M-3P18.8 SEER2 · 9.2 HSPF2
- TOSOT TWH24R32DO · cold climate19.0 SEER2 · 8.5 HSPF2
- MDV MOX430-24HFN10-M1E · cold climate18.7 SEER2 · 9.3 HSPF2
- TOSOT SU-COSMO24-230/O · cold climate19.0 SEER2 · 8.5 HSPF2
- MRCOOL A-24-HP-C-230D-O · cold climate18.7 SEER2 · 9.3 HSPF2
- Ouellet OCHX-H24A-O · cold climate19.0 SEER2 · 8.5 HSPF2
- Mitsubishi Electric SUZ-AK24NLHZ2 · cold climate18.6 SEER2 · 8.9 HSPF2
See all 430 24,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 13, 2026. How we use the data.