HVAC Rated

24,000 BTU mini-split heat pump · A Series

MRCOOL A-24-HP-C-230D-O

Below average cooling and heating efficiency for a 24,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #395 of 430 24,000 BTU mini-splits for cooling efficiency, and costs about $679 a year to run in a mixed climate like Atlanta.

SEER2
18.7 Cooling efficiency over a season
Below average · beats 7%
HSPF2
9.3 Heating efficiency over a season
Below average · beats 18%
EER2
10.0 Cooling efficiency on a 95°F day
Below average · beats 5%
Heat at 5°F
17,000 BTU/h71% of its 47°F output
Very good · beats 73%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 17,000 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for mini-splits.
  • You mainly need heat - its HSPF2 is below average for mini-splits.

Calculate my running cost

Details

Specifications24,000 BTU, R-454B
General
BrandMRCOOL
Also sold asAC Pro, Cooper&Hunter, Breeze33, Star Air Kontrol, Senville
Outdoor unit modelA-24-HP-C-230D-O
SeriesA Series
TypeMini-split heat pump
Nominal size24,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceOctober 25, 2024
Last certifiedMay 6, 2026
Cooling
SEER2Seasonal efficiency, higher is better18.7 (range 18.7)
EER2Efficiency at 95°F outdoors10.0
Cooling capacity24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.3
Capacity at 47°F24,000 BTU/h
Capacity at 17°F20,800 BTU/h
Capacity at 5°F17,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.14
ENERGY STAR cold climateYes
Heating output as it gets colder71% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with A-24-HP-WMAH-230D-O at the standard test temperatures, in BTU/h:

Certified matchups1 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
A-24-HP-WMAH-230D-O · cold climate18.710.09.317,000216032586
Same unit, other model numbers5

These model numbers have exactly the same certified ratings and matchups as the MRCOOL A-24-HP-C-230D-O: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$603-$1,627

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the MRCOOL A-24-HP-C-230D-O?
The MRCOOL A-24-HP-C-230D-O is rated at up to 18.7 SEER2 and 10.0 EER2 for cooling and up to 9.3 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the MRCOOL A-24-HP-C-230D-O good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 17,000 BTU/h at 5°F with a COP of 2.14, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
How much does the MRCOOL A-24-HP-C-230D-O cost to run per year?
At its rated efficiency it costs about $603-$1,627 a year in electricity in large U.S. cities, depending on climate and local rates - for example $746 in Phoenix and $1,361 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the MRCOOL A-24-HP-C-230D-O the same as the AC Pro MHPC-J-024BSB?
Yes, as far as the certified ratings go. ENERGY STAR lists 6 model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the MRCOOL A-24-HP-C-230D-O?
ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses A-24-HP-WMAH-230D-O.
What refrigerant does the MRCOOL A-24-HP-C-230D-O use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $741/yrYou save $497/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump MRCOOL A-24-HP-C-230D-O
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$741
Current system, per year
$1,238
You save per year
$497
Payback
18.1 years
Net after 10 years
-$4,033

Cooling $452Heating $289Electricity used: 4,630 kWhSaved vs. a minimum-efficiency heat pump: $208

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 24,000 BTU models

See all 430 24,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 6, 2026. How we use the data.