HVAC Rated

1.5-ton central heat pump · HRG15 Series

Comfort-Aire HRG1518S1R-**A

Average cooling efficiency and below average heating efficiency for a 1.5-ton central heat pump, but not rated for cold climates.

Ranks #76 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $545 a year to run in a mixed climate like Atlanta.

SEER2
16.8 Cooling efficiency over a season
Average · beats 45%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
13.5 Cooling efficiency on a 95°F day
Excellent · beats 95%
Heat at 5°F
9,300 BTU/h45% of its 47°F output
Average · beats 67%

A good fit if…

  • You want a choice of indoor units - 142 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications1.5 ton, R-410A
General
BrandComfort-Aire
Also sold asCentury
Outdoor unit modelHRG1518S1R-**A
SeriesHRG15 Series
TypeCentral heat pump
Nominal size1.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceJanuary 5, 2022
Last certifiedMay 27, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.8 (range 15.2-16.8)
EER2Efficiency at 95°F outdoors12.5-14.0
Cooling capacity18,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F16,800-18,000 BTU/h
Capacity at 17°F10,200-11,800 BTU/h
Capacity at 5°F7,500-9,300 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.92-2.14
ENERGY STAR cold climateNo
Heating output as it gets colder45% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EA(C;U)1P30A+TDR+TXV at the standard test temperatures, in BTU/h:

Certified matchups142 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 142 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
EA(C;U)1P30A+TDR+TXVGUH97M070B3M16.813.58.07,800210421121
EA(C;U)1P30A+TDR+TXVGUH97M070B3M16.813.58.07,800210421059
7EH30BX-0*+TDRGUH80C070B3M16.813.58.07,700214712825
7EH30BX-0*+TDRGUH92C045B3M16.813.58.07,900214712827
7EH30BX-0*+TDRGUH92C070B3M16.813.58.07,600214712828
7EH30BX-0*+TDRGUH97M070B3M16.814.08.07,800214712831
7EC30BX-0*+TDRGUH97M070B3M16.813.58.07,800214712867
7EC30BX-0*+TDRGUH97M070B3M16.813.58.07,800214716691
7EH30BX-0*+TDRGUH80C070B3M16.813.58.07,700214716649
7EH30BX-0*+TDRGUH92C045B3M16.813.58.07,900214716651
7EH30BX-0*+TDRGUH92C070B3M16.813.58.07,600214716652
7EH30BX-0*+TDRGUH97M070B3M16.814.08.07,800214716655
EA(C;U)1P30A+TDR+TXVGUH80C045A3M16.813.57.87,700210421051
EA(C;U)1P30A+TDR+TXVGUH80C070B3M16.813.57.87,700210421114
EA(C;U)1P30A+TDR+TXVGUH80C045A3M16.813.57.87,700210421113
EA(C;U)1P30A+TDR+TXVGUH80C070B3M16.813.57.87,700210421052
7EC30AX-0*+TDRGUH80C045A3M16.813.57.87,700214712857
7EC30BX-0*+TDRGUH80C070B3M16.813.57.87,700214712861
7EC30AX-0*+TDRGUH80C045A3M16.813.57.87,700214716681
7EC30BX-0*+TDRGUH80C070B3M16.813.57.87,700214716685
EAD4X-30/36B+TDRGDD92C070B3M16.614.08.58,900213265415
EAD4X-30/36B+TDRGDD92C070B3M16.614.08.58,900213265465
7ED30/36BX-0*+TDRGDD92C070B3M16.614.08.58,900214712835
7ED30/36BX-0*+TDRGDD92C070B3M16.614.08.58,900214716659
EAD4X-30/36B+TDRGDD92C045B3M16.614.08.48,900213265414
EAD4X-30/36B+TDRGDD92C045B3M16.614.08.48,900213265464
7ED30/36BX-0*+TDRGDD92C045B3M16.614.08.48,900214712834
7ED30/36BX-0*+TDRGDD92C045B3M16.614.08.48,900214716658
EA(C;U)1P30A+TDR+TXVGUH92C070B3M16.613.57.87,700210421056
EA(C;U)1P30A+TDR+TXVGUH92C070B3M16.613.57.87,700210421118
7EC30BX-0*+TDRGUH92C070B3M16.613.57.87,700214712864
7EC30BX-0*+TDRGUH92C070B3M16.613.57.87,700214716688
EAD4X-30/36B+TDRGDD96C045B3M16.413.58.38,700213265466
EAD4X-30/36B+TDRGDD96C045B3M16.413.58.38,700213265416
7ED30/36BX-0*+TDRGDD96C045B3M16.413.58.38,700214712836
7ED30/36BX-0*+TDRGDD96C045B3M16.413.58.38,700214716660
EA(C;U)1P24A+TDR+TXVGUH97M070B3M16.413.58.18,400210421109
EA(C;U)1P24A+TDR+TXVGUH97M070B3M16.413.58.18,400210421047
7EC24BX-0*+TDRGUH97M070B3M16.413.58.18,400214712853
7EH24BX-0*+TDRGUH97M070B3M16.413.58.18,400214712822
7EH24BX-0*+TDRGUH80C070B3M16.413.58.18,200214712816
7EH24BX-0*+TDRGUH92C045B3M16.413.58.18,200214712818
7EH24BX-0*+TDRGUH92C070B3M16.413.58.18,200214712819
7EC24BX-0*+TDRGUH97M070B3M16.413.58.18,400214716677
7EH24BX-0*+TDRGUH80C070B3M16.413.58.18,200214716640
7EH24BX-0*+TDRGUH92C045B3M16.413.58.18,200214716642
7EH24BX-0*+TDRGUH92C070B3M16.413.58.18,200214716643
7EH24BX-0*+TDRGUH97M070B3M16.413.58.18,400214716646
EA(C;U)1P24A+TDR+TXVGUH80C070A3M16.413.58.08,200210421038
EA(C;U)1P24A+TDR+TXVGUH80C070B3M16.413.58.08,200210421102
EA(C;U)1P24A+TDR+TXVGUH80C070A3M16.413.58.08,200210421100
EA(C;U)1P24A+TDR+TXVGUH80C070B3M16.413.58.08,200210421040
7EC24BX-0*+TDRGUH80C070B3M16.413.58.08,200214712847
7EH24AX-0*+TDRGUH80C045A3M16.413.58.08,000214712813
7EH24AX-0*+TDRGUH80C070A3M16.413.58.08,000214712814
7EC24AX-0*+TDRGUH80C070A3M16.413.58.08,200214712845
7EH24AX-0*+TDRGUH80C045A3M16.413.58.08,000214716637
7EH24AX-0*+TDRGUH80C070A3M16.413.58.08,000214716638
7EC24AX-0*+TDRGUH80C070A3M16.413.58.08,200214716669
7EC24BX-0*+TDRGUH80C070B3M16.413.58.08,200214716671
Yearly running cost in 10 large cities$503-$1,291

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Comfort-Aire HRG1518S1R-**A?
The Comfort-Aire HRG1518S1R-**A is rated at up to 16.8 SEER2 and 13.5 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 142 certified matchups SEER2 ranges from 15.2-16.8.
Is the Comfort-Aire HRG1518S1R-**A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 1.5-ton model.
How much does the Comfort-Aire HRG1518S1R-**A cost to run per year?
At its rated efficiency it costs about $503-$1,291 a year in electricity in large U.S. cities, depending on climate and local rates - for example $612 in Phoenix and $1,073 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Comfort-Aire HRG1518S1R-**A?
ENERGY STAR lists 142 certified combinations for this outdoor unit. The highest-rated ones use EA(C;U)1P30A+TDR+TXV, 7EH30BX-0*+TDR, 7EC30BX-0*+TDR.
What refrigerant does the Comfort-Aire HRG1518S1R-**A use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $604/yrYou save $311/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Comfort-Aire HRG1518S1R-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$604
Current system, per year
$915
You save per year
$311
Payback
22.5 years
Net after 10 years
-$3,887

Cooling $377Heating $227Electricity used: 3,774 kWhSaved vs. a minimum-efficiency heat pump: $96

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 1.5 ton models

See all 170 1.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 27, 2026. How we use the data.