HVAC Rated

1.5-ton central heat pump · ELITE EL17XP1 Series

Lennox EL17XP1-018-230A

Average cooling efficiency and below average heating efficiency for a 1.5-ton central heat pump, but not rated for cold climates.

Ranks #79 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $549 a year to run in a mixed climate like Atlanta.

SEER2
16.8 Cooling efficiency over a season
Average · beats 45%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
14.0 Cooling efficiency on a 95°F day
Excellent · beats 98%
Heat at 5°F
9,700 BTU/h45% of its 47°F output
Very good · beats 70%

A good fit if…

  • You want a choice of indoor units - 459 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications1.5 ton, R-410A
General
BrandLennox
Outdoor unit modelEL17XP1-018-230A
SeriesELITE EL17XP1 Series
TypeCentral heat pump
Nominal size1.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceJanuary 5, 2022
Last certifiedOctober 27, 2025
Cooling
SEER2Seasonal efficiency, higher is better16.8 (range 15.2-16.8)
EER2Efficiency at 95°F outdoors12.2-14.0
Cooling capacity17,800-18,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F16,000-18,000 BTU/h
Capacity at 17°F10,200-12,100 BTU/h
Capacity at 5°F7,500-9,700 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.90-2.16
ENERGY STAR cold climateNo
Heating output as it gets colder45% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CHX35-30B-**-*+TDR at the standard test temperatures, in BTU/h:

Certified matchups459 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 459 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CHX35-30B-**-*+TDRSL297UH060NV36B*16.814.08.17,800210288978
CX35-30B+TDRML180UH070V48B*16.813.58.18,000210290607
CHX35-24B-**-*+TDRSL280UH090V36B*16.814.08.18,400210288942
CHX35-24A-**-*+TDRSL280UH060NV36A*16.814.08.18,200210288911
CX35-30B+TDRSL280UH080NV48B*16.814.08.17,800210290633
CX35-30B+TDRSL280UH090V36B*16.814.08.18,000210290636
C35-30B+TDR+TXVML180UH070V48B*16.813.58.18,000210288799
CHX35-30B-**-*+TDRML180UH070V48B*16.814.08.18,000210288962
C35-30B+TDR+TXVSL280UH080NV48B*16.814.08.17,800210288811
CHX35-30B-**-*+TDRSL280UH080NV48B*16.814.08.18,000210288974
CHX35-24B-**-*+TDRSL280UH080NV48B*16.814.08.18,400210288941
C35-30B+TDR+TXVSL280UH090V36B*16.814.08.18,000210288812
CK40HT-24A-0*+TDRSL280UH060NV36A*16.814.08.18,200214621832
CK40HT-24B-0*+TDRSL280UH080NV48B*16.814.08.18,400214621862
CK40HT-24B-0*+TDRSL280UH090V36B*16.814.08.18,400214621863
CK40HT-30B-0*+TDRML180UH070V48B*16.814.08.18,000214621884
CK40HT-30B-0*+TDRSL280UH080NV48B*16.814.08.18,000214621896
CK40HT-30B-0*+TDRSL297UH060NV36B*16.814.08.17,800214621900
CK40CT-30B-0*+TDRML180UH070V48B*16.813.58.18,000214622003
CK40CT-30B-0*+TDRSL280UH080NV48B*16.814.08.17,800214622015
CK40CT-30B-0*+TDRSL280UH090V36B*16.814.08.18,000214622016
C35-30A+TDR+TXVEL280UH070XE36A*16.813.58.07,600210288775
C35-30B+TDR+TXVSL297UH040NV36B*16.813.58.07,800210288814
CX35-30A+TDRSL280UH060NV36A*16.814.08.07,900210290563
C35-30A+TDR+TXVSL280UH060NV36A*16.814.08.07,900210288782
CHX35-30B-**-*+TDRML180UH070V36B*16.814.08.07,700210288961
C35-30B+TDR+TXVSL297UH060NV36B*16.813.58.07,800210288815
CHX35-30B-**-*+TDRML193UH045XE36B*16.813.58.07,900210288966
CHX35-30B-**-*+TDRML180UH070E36B*16.813.58.07,700210288960
CHX35-30B-**-*+TDREL280UH090E36B*16.814.08.07,600210288953
CX35-30A+TDREL280UH070E36A*16.813.58.07,600210290542
CHX35-30B-**-*+TDRSLP99UH070XV36B*16.814.08.07,800210288979
CX35-30A+TDREL280UH070XE36A*16.813.58.07,600210290545
CHX35-30B-**-*+TDRML193UH070XE36B*16.813.58.07,600210288967
CX35-30B+TDRSL297UH060NV36B*16.813.58.07,800210290645
C35-30B+TDR+TXVEL280UH090E36B*16.814.08.07,600210288791
C35-30A+TDR+TXVEL280UH070E36A*16.813.58.07,600210288774
CX35-30B+TDREL280UH090E36B*16.814.08.07,600210290582
CX35-30B+TDRSLP99UH070XV36B*16.813.58.07,800210290650
C35-30B+TDR+TXVSLP99UH070XV36B*16.813.58.07,800210288816
CHX35-30B-**-*+TDRSL297UH040NV36B*16.814.08.07,800210288977
CX35-30B+TDRSL297UH040NV36B*16.813.58.07,800210290643
C35-30B+TDR+TXVEL297UH070XV36B*16.813.58.07,800213194554
CX35-30B+TDREL297UH070XV36B*16.813.58.07,800213194562
CHX35-30B-**-*+TDREL297UH070XV36B*16.814.08.07,800213194558
CK40HT-30B-0*+TDREL280UH090E36B*16.814.08.07,600214621875
CK40CT-30A-0*+TDREL280UH070E36A*16.813.58.07,600214621976
CK40CT-30A-0*+TDREL280UH070XE36A*16.813.58.07,600214621977
CK40HT-30B-0*+TDREL297UH070XV36B*16.814.08.07,800214621881
CK40HT-30B-0*+TDRML180UH070V36B*16.814.08.07,700214621883
CK40HT-30B-0*+TDRML180UH070E36B*16.813.58.07,700214621882
CK40HT-30B-0*+TDRML193UH045XE36B*16.813.58.07,900214621888
CK40HT-30B-0*+TDRML193UH070XE36B*16.813.58.07,600214621889
CK40HT-30B-0*+TDRSL297UH040NV36B*16.814.08.07,800214621899
CK40HT-30B-0*+TDRSLP99UH070XV36B*16.814.08.07,800214621901
CK40CT-30A-0*+TDRSL280UH060NV36A*16.814.08.07,900214621984
CK40CT-30B-0*+TDREL280UH090E36B*16.814.08.07,600214621994
CK40CT-30B-0*+TDREL297UH070XV36B*16.813.58.07,800214622000
CK40CT-30B-0*+TDRSL297UH040NV36B*16.813.58.07,800214622018
CK40CT-30B-0*+TDRSL297UH060NV36B*16.813.58.07,800214622019
Yearly running cost in 10 large cities$503-$1,303

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Lennox EL17XP1-018-230A?
The Lennox EL17XP1-018-230A is rated at up to 16.8 SEER2 and 14.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 459 certified matchups SEER2 ranges from 15.2-16.8.
Is the Lennox EL17XP1-018-230A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 1.5-ton model.
How much does the Lennox EL17XP1-018-230A cost to run per year?
At its rated efficiency it costs about $503-$1,303 a year in electricity in large U.S. cities, depending on climate and local rates - for example $614 in Phoenix and $1,084 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Lennox EL17XP1-018-230A?
ENERGY STAR lists 459 certified combinations for this outdoor unit. The highest-rated ones use CHX35-30B-**-*+TDR, CX35-30B+TDR, CHX35-24B-**-*+TDR.
What refrigerant does the Lennox EL17XP1-018-230A use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $606/yrYou save $312/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Lennox EL17XP1-018-230A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$606
Current system, per year
$918
You save per year
$312
Payback
22.4 years
Net after 10 years
-$3,881

Cooling $377Heating $229Electricity used: 3,790 kWhSaved vs. a minimum-efficiency heat pump: $97

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 1.5 ton models

See all 170 1.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.