1.5-ton central heat pump · MHP170 SERIES
MRCOOL MHP17018A-**A
Average cooling efficiency and below average heating efficiency for a 1.5-ton central heat pump, but not rated for cold climates.
Ranks #83 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $562 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.8 Cooling efficiency over a seasonAverage · beats 45%
- HSPF2
- 8.1 Heating efficiency over a seasonBelow average · beats 20%
- EER2
- 13.5 Cooling efficiency on a 95°F dayExcellent · beats 95%
- Heat at 5°F
- 8,500 BTU/h45% of its 47°F outputAverage · beats 67%
A good fit if…
- You want a choice of indoor units - 24 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | MRCOOL |
| Outdoor unit model | MHP17018A-**A |
| Series | MHP170 SERIES |
| Type | Central heat pump |
| Nominal size | 1.5 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | January 5, 2022 |
| Last certified | May 27, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.8 (range 15.2-16.8) |
| EER2Efficiency at 95°F outdoors | 12.5-13.5 |
| Cooling capacity | 18,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.1 |
| Capacity at 47°F | 17,000-17,900 BTU/h |
| Capacity at 17°F | 10,400-11,200 BTU/h |
| Capacity at 5°F | 7,700-8,500 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.92-2.14 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with MCVP30ANPA+TDR+TXV at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| MCVP30ANPA+TDR+TXV | MGM80SE045A3A | 16.8 | 13.5 | 7.8 | 7,700 | 210326225 |
| MCVP24ANPA+TDR+TXV | MGM80SE070B3A | 16.4 | 13.5 | 8.0 | 8,200 | 210326210 |
| MCHP24ANPA*+TDR+TXV | MGM80SE070B3A | 16.4 | 13.5 | 8.0 | 8,000 | 211734359 |
| MCHP24ANPA*+TDR+TXV | MGM80SE045A3A | 16.4 | 13.5 | 8.0 | 8,000 | 211734339 |
| MCVP30ANPA+TDR+TXV | MGM96SE070B3XA | 16.4 | 13.5 | 7.8 | 7,700 | 210326229 |
| MCVP30BNPA+TDR+TXV | MGM96SE070B3XA | 16.4 | 13.5 | 7.8 | 7,700 | 210441040 |
| MCVP30BNPA+TDR+TXV | MGM96SE045B3XA | 16.4 | 13.5 | 7.8 | 7,700 | 210441039 |
| MCVP30ANPA+TDR+TXV | MGM96SE045B3XA | 16.4 | 13.5 | 7.8 | 7,700 | 210326227 |
| MCVP30ANPA+TDR+TXV | MGM80SE070B3A | 16.4 | 13.5 | 7.8 | 7,700 | 210326223 |
| MCHP30BNPA*+TDR+TXV | MGM96SE045B3XA | 16.4 | 13.5 | 7.8 | 7,700 | 211734809 |
| MCHP30BNPA*+TDR+TXV | MGM96SE070B3XA | 16.4 | 13.5 | 7.8 | 7,700 | 211734830 |
| MCVP24ANPA+TDR+TXV | MGM80SE045A3A | 16.2 | 13.5 | 8.0 | 8,200 | 210326212 |
| MAHM024ETA | - | 16.0 | 13.0 | 8.1 | 8,500 | 211174467 |
| MCHP24BNPA*+TDR+TXV | MGM96SE045B3XA | 16.0 | 13.5 | 8.1 | 8,200 | 211734601 |
| MCHP24BNPA*+TDR+TXV | MGM96SE070B3XA | 16.0 | 13.5 | 8.1 | 8,200 | 211734613 |
| MCVP24BNPA+TDR+TXV | MGM96SE045B3XA | 16.0 | 13.5 | 8.0 | 8,200 | 210441036 |
| MCVP24ANPA+TDR+TXV | MGM96SE070B3XA | 16.0 | 13.5 | 8.0 | 8,200 | 210326217 |
| MCVP24BNPA+TDR+TXV | MGM96SE070B3XA | 16.0 | 13.5 | 8.0 | 8,200 | 210441037 |
| MCVP24ANPA+TDR+TXV | MGM96SE045B3XA | 16.0 | 13.5 | 8.0 | 8,200 | 210326215 |
| MCHP30BNPA*+TDR+TXV | MGM80SE090B4A | 15.6 | 13.0 | 7.8 | 8,000 | 211734748 |
| MAHM024CTA | - | 15.4 | 13.0 | 8.1 | 8,500 | 211174374 |
| MAHM018CTA | - | 15.2 | 13.0 | 8.0 | 8,500 | 210324692 |
| MCVP30ANPA+TDR+TXV | MGM80SE090B4A | 15.2 | 12.5 | 7.8 | 8,100 | 210326231 |
| MCVP30BNPA+TDR+TXV | MGM80SE090B4A | 15.2 | 12.5 | 7.8 | 8,100 | 210441038 |
Yearly running cost in 10 large cities
- Phoenix, AZ$620/yr
- Miami, FL$503/yr
- Houston, TX$556/yr
- Atlanta, GA$562/yr
- Los Angeles, CA$547/yr
- New York, NY$1,342/yr
- Chicago, IL$1,090/yr
- Denver, CO$906/yr
- Seattle, WA$557/yr
- Minneapolis, MN$1,121/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the MRCOOL MHP17018A-**A?
- The MRCOOL MHP17018A-**A is rated at up to 16.8 SEER2 and 13.5 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 24 certified matchups SEER2 ranges from 15.2-16.8.
- Is the MRCOOL MHP17018A-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 1.5-ton model.
- How much does the MRCOOL MHP17018A-**A cost to run per year?
- At its rated efficiency it costs about $503-$1,342 a year in electricity in large U.S. cities, depending on climate and local rates - for example $620 in Phoenix and $1,121 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the MRCOOL MHP17018A-**A?
- ENERGY STAR lists 24 certified combinations for this outdoor unit. The highest-rated ones use MCVP30ANPA+TDR+TXV, MCVP24ANPA+TDR+TXV, MCHP24ANPA*+TDR+TXV.
- What refrigerant does the MRCOOL MHP17018A-**A use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 1.5 ton models
- Century HRG1**8S1R-**A16.8 SEER2 · 8.1 HSPF2
- Blueridge BHP17L18P-**A16.8 SEER2 · 8.4 HSPF2
- Bryant 37MUHAQ18AA3+KSAIC0701230 · cold climate16.5 SEER2 · 9.0 HSPF2
- Lennox ML17XP1-018-230A16.8 SEER2 · 8.5 HSPF2
- Tempstar D5CUHAH18AAK+KSAIC0701230 · cold climate16.5 SEER2 · 9.0 HSPF2
- Lennox EL17XP1-018-230A16.8 SEER2 · 8.5 HSPF2
- Innovair SEV18H2R1916.5 SEER2 · 8.6 HSPF2
- GE NS17H18SA4-**A16.8 SEER2 · 8.5 HSPF2
See all 170 1.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 27, 2026. How we use the data.