1.5-ton central heat pump · Crossover Heat Pump
Bryant 37MUHAQ18AA3+KSAIC0701230
Average cooling and heating efficiency for a 1.5-ton central heat pump, and certified for cold climates.
Ranks #85 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $575 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.5 Cooling efficiency over a seasonAverage · beats 40%
- HSPF2
- 9.0 Heating efficiency over a seasonAverage · beats 54%
- EER2
- 10.5 Cooling efficiency on a 95°F dayBelow average · beats 17%
- Heat at 5°F
- 17,600 BTU/h85% of its 47°F outputAverage · beats 48%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 17,600 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 246 certified pairings.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Bryant |
| Also sold as | Carrier, PAYNE HEATING AND COOLING, WeatherMaker |
| Outdoor unit model | 37MUHAQ18AA3+KSAIC0701230 |
| Series | Crossover Heat Pump |
| Type | Central heat pump |
| Nominal size | 1.5 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | May 6, 2025 |
| Last certified | October 7, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.5 (range 15.2-16.5) |
| EER2Efficiency at 95°F outdoors | 10.0-11.0 |
| Cooling capacity | 17,400-18,700 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.1-9.0 |
| Capacity at 47°F | 18,900-20,200 BTU/h |
| Capacity at 17°F | 14,400-15,300 BTU/h |
| Capacity at 5°F | 16,300-17,600 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.85-2.04 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FMA5X18**AL at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 246 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| FMA5X18**AL · cold climate | - | 16.5 | 10.5 | 8.5 | 16,800 | 218473018 |
| FMA5X24**AL · cold climate | - | 16.5 | 10.5 | 8.5 | 16,800 | 218473017 |
| FMA5X18**AL · cold climate | - | 16.5 | 10.5 | 8.5 | 16,800 | 218475449 |
| FMA5X18**AL · cold climate | - | 16.5 | 10.5 | 8.5 | 16,800 | 218475448 |
| FMA5X24**AL · cold climate | - | 16.5 | 10.5 | 8.5 | 16,800 | 218475447 |
| FMA5X24**AL · cold climate | - | 16.5 | 10.5 | 8.5 | 16,800 | 218475446 |
| FM(C,U)5Z30**AL · cold climate | - | 16.0 | 11.0 | 9.0 | 16,800 | 218473019 |
| FM(C,U)5Z30**AL · cold climate | - | 16.0 | 11.0 | 9.0 | 16,800 | 218475451 |
| FM(C,U)5Z30**AL · cold climate | - | 16.0 | 11.0 | 9.0 | 16,800 | 218475450 |
| FM(C,U)5Z18**AL · cold climate | - | 16.0 | 10.5 | 9.0 | 17,100 | 218814842 |
| FT5ANXB24L · cold climate | - | 16.0 | 11.0 | 8.5 | 17,400 | 218473010 |
| FG5ANXB24L · cold climate | - | 16.0 | 11.0 | 8.5 | 17,400 | 218475461 |
| FG5ANXB24L · cold climate | - | 16.0 | 11.0 | 8.5 | 17,400 | 218475460 |
| PF5TNXB24L · cold climate | - | 16.0 | 11.0 | 8.5 | 17,400 | 218475441 |
| FT5ANXB24L · cold climate | - | 16.0 | 11.0 | 8.5 | 17,400 | 218475372 |
| PF5TNXB24L · cold climate | - | 16.0 | 11.0 | 8.5 | 17,400 | 218475371 |
| FEVB0024**+NAVA53601CK · cold climate | - | 16.0 | 10.5 | 8.5 | 16,500 | 218814845 |
| FJ5AN*A18L · cold climate | - | 16.0 | 10.5 | 8.5 | 16,800 | 218814844 |
| PF5TNXB24L · cold climate | - | 16.0 | 11.0 | 8.5 | 17,400 | 218814829 |
| FM(C,U)5Z18**AL · cold climate | - | 15.5 | 10.5 | 9.0 | 17,100 | 218473021 |
| FM(C,U)5Z24**AL · cold climate | - | 15.5 | 10.5 | 9.0 | 17,100 | 218473020 |
| FM(C,U)5Z18**AL · cold climate | - | 15.5 | 10.5 | 9.0 | 17,100 | 218475455 |
| FM(C,U)5Z18**AL · cold climate | - | 15.5 | 10.5 | 9.0 | 17,100 | 218475454 |
| FM(C,U)5Z24**AL · cold climate | - | 15.5 | 10.5 | 9.0 | 17,100 | 218475453 |
| FM(C,U)5Z24**AL · cold climate | - | 15.5 | 10.5 | 9.0 | 17,100 | 218475452 |
| CAA**1917AM · cold climate | OVLAAB036098 | 15.5 | 10.5 | 8.5 | 17,400 | 218473231 |
| CAA**1917AM · cold climate | 59SC2E080M17**16 | 15.5 | 10.5 | 8.5 | 16,600 | 218473213 |
| CAA**1917AM · cold climate | 58S(B,C)*B070M17**16 | 15.5 | 10.5 | 8.5 | 16,400 | 218473201 |
| CAA**1917AM · cold climate | 58S(B,C)*B070M14**12 | 15.5 | 10.5 | 8.5 | 16,500 | 218473200 |
| CAA**1917AM · cold climate | 58S(B,C)*B045M14**12 | 15.5 | 10.5 | 8.5 | 16,400 | 218473199 |
| CAA**2517AM · cold climate | OVLAAB036098 | 15.5 | 10.5 | 8.5 | 17,500 | 218473152 |
| CAA**2517AM · cold climate | 59SC2E080M17**16 | 15.5 | 10.5 | 8.5 | 16,500 | 218473134 |
| CAA**2517AM · cold climate | 58S(B,C)*B070M17**16 | 15.5 | 10.5 | 8.5 | 16,300 | 218473119 |
| CAA**2517AM · cold climate | 58S(B,C)*B070M17**12 | 15.5 | 10.5 | 8.5 | 16,400 | 218473118 |
| CAA**2517AM · cold climate | 58S(B,C)*B070M14**12 | 15.5 | 10.5 | 8.5 | 16,400 | 218473117 |
| CAA**2517AM · cold climate | 58S(B,C)*B045M14**12 | 15.5 | 10.5 | 8.5 | 16,400 | 218473115 |
| CAA**1917AM · cold climate | OVLAAB036098 | 15.5 | 10.5 | 8.5 | 17,400 | 218475840 |
| CAA**1917AM · cold climate | PG92MSAA48080B** | 15.5 | 10.5 | 8.5 | 16,600 | 218475807 |
| CAA**1917AM · cold climate | 912SE48080M17*** | 15.5 | 10.5 | 8.5 | 16,600 | 218475806 |
| CAA**1917AM · cold climate | PG80MS(A,L)A48070B** | 15.5 | 10.5 | 8.5 | 16,400 | 218475785 |
| CAA**1917AM · cold climate | 8(0,1)*SB48070M17*** | 15.5 | 10.5 | 8.5 | 16,400 | 218475784 |
| CAA**1917AM · cold climate | PG80MS(A,L)A36070A** | 15.5 | 10.5 | 8.5 | 16,500 | 218475783 |
| CAA**1917AM · cold climate | 8(0,1)*SB36070M14*** | 15.5 | 10.5 | 8.5 | 16,500 | 218475782 |
| CAA**1917AM · cold climate | PG80MS(A,L)A36045A** | 15.5 | 10.5 | 8.5 | 16,400 | 218475781 |
| CAA**1917AM · cold climate | 8(0,1)*SB36045M14*** | 15.5 | 10.5 | 8.5 | 16,400 | 218475780 |
| CAA**2517AM · cold climate | OVLAAB036098 | 15.5 | 10.5 | 8.5 | 17,500 | 218475697 |
| CAA**2517AM · cold climate | PG92MSAA48080B** | 15.5 | 10.5 | 8.5 | 16,500 | 218475664 |
| CAA**2517AM · cold climate | 912SE48080M17*** | 15.5 | 10.5 | 8.5 | 16,500 | 218475663 |
| CAA**2517AM · cold climate | PG80MS(A,L)A48070B** | 15.5 | 10.5 | 8.5 | 16,300 | 218475637 |
| CAA**2517AM · cold climate | 8(0,1)*SB48070M17*** | 15.5 | 10.5 | 8.5 | 16,300 | 218475636 |
| CAA**2517AM · cold climate | PG80MS(A,L)A36070B** | 15.5 | 10.5 | 8.5 | 16,400 | 218475635 |
| CAA**2517AM · cold climate | 8(0,1)*SB36070M17*** | 15.5 | 10.5 | 8.5 | 16,400 | 218475634 |
| CAA**2517AM · cold climate | PG80MS(A,L)A36070A** | 15.5 | 10.5 | 8.5 | 16,400 | 218475633 |
| CAA**2517AM · cold climate | 8(0,1)*SB36070M14*** | 15.5 | 10.5 | 8.5 | 16,400 | 218475632 |
| CAA**2517AM · cold climate | PG80MS(A,L)A36045A** | 15.5 | 10.5 | 8.5 | 16,400 | 218475629 |
| CAA**2517AM · cold climate | 8(0,1)*SB36045M14*** | 15.5 | 10.5 | 8.5 | 16,400 | 218475628 |
| CAA**1917AM · cold climate | PG92MSAA48080B** | 15.5 | 10.5 | 8.5 | 16,600 | 218814991 |
| CAA**1917AM · cold climate | PG80MS(A,L)A48070B** | 15.5 | 10.5 | 8.5 | 16,400 | 218814981 |
| CAA**1917AM · cold climate | PG80MS(A,L)A36070A** | 15.5 | 10.5 | 8.5 | 16,500 | 218814980 |
| CAA**1917AM · cold climate | PG80MS(A,L)A36045A** | 15.5 | 10.5 | 8.5 | 16,400 | 218814979 |
Yearly running cost in 10 large cities
- Phoenix, AZ$633/yr
- Miami, FL$513/yr
- Houston, TX$567/yr
- Atlanta, GA$575/yr
- Los Angeles, CA$559/yr
- New York, NY$1,375/yr
- Chicago, IL$1,116/yr
- Denver, CO$928/yr
- Seattle, WA$571/yr
- Minneapolis, MN$1,149/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Bryant 37MUHAQ18AA3+KSAIC0701230?
- The Bryant 37MUHAQ18AA3+KSAIC0701230 is rated at up to 16.5 SEER2 and 10.5 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 246 certified matchups SEER2 ranges from 15.2-16.5.
- Is the Bryant 37MUHAQ18AA3+KSAIC0701230 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 17,600 BTU/h at 5°F with a COP of 2.04, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the Bryant 37MUHAQ18AA3+KSAIC0701230 cost to run per year?
- At its rated efficiency it costs about $513-$1,375 a year in electricity in large U.S. cities, depending on climate and local rates - for example $633 in Phoenix and $1,149 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Bryant 37MUHAQ18AA3+KSAIC0701230?
- ENERGY STAR lists 246 certified combinations for this outdoor unit. The highest-rated ones use FMA5X18**AL, FMA5X24**AL, FM(C,U)5Z30**AL.
- What refrigerant does the Bryant 37MUHAQ18AA3+KSAIC0701230 use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 1.5 ton models
- MRCOOL MVP-18-HP-C-230-2516.6 SEER2 · 10.2 HSPF2
- Tempstar D5CUHAH18AAK+KSAIC0701230 · cold climate16.5 SEER2 · 9.0 HSPF2
- MRCOOL MHP17018A-**A16.8 SEER2 · 8.1 HSPF2
- Innovair SEV18H2R1916.5 SEER2 · 8.6 HSPF2
- Century HRG1**8S1R-**A16.8 SEER2 · 8.1 HSPF2
- MDV MOX330U-18HFN1-MR016.5 SEER2 · 8.6 HSPF2
- Blueridge BHP17L18P-**A16.8 SEER2 · 8.4 HSPF2
- Daikin DH6VSA181MA16.5 SEER2 · 8.5 HSPF2
See all 170 1.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 7, 2026. How we use the data.