1.5-ton central heat pump · HRG15 Series
Century HRG1**8S1R-**A
Average cooling efficiency and below average heating efficiency for a 1.5-ton central heat pump, but not rated for cold climates.
Ranks #82 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $562 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.8 Cooling efficiency over a seasonAverage · beats 45%
- HSPF2
- 8.1 Heating efficiency over a seasonBelow average · beats 20%
- EER2
- 13.5 Cooling efficiency on a 95°F dayExcellent · beats 95%
- Heat at 5°F
- 8,400 BTU/h45% of its 47°F outputAverage · beats 58%
A good fit if…
- You want a choice of indoor units - 64 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | Century |
| Also sold as | Comfort-Aire |
| Outdoor unit model | HRG1**8S1R-**A |
| Series | HRG15 Series |
| Type | Central heat pump |
| Nominal size | 1.5 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | October 25, 2022 |
| Last certified | October 27, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.8 (range 15.2-16.8) |
| EER2Efficiency at 95°F outdoors | 12.5-14.0 |
| Cooling capacity | 18,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.1 |
| Capacity at 47°F | 17,000-18,000 BTU/h |
| Capacity at 17°F | 10,400-11,200 BTU/h |
| Capacity at 5°F | 7,600-8,400 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.92-2.10 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EA(C;U)1P30A+TDR+TXV at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 64 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| EA(C;U)1P30A+TDR+TXV | GUH97M070B3M | 16.8 | 13.5 | 8.0 | 7,800 | 210330536 |
| EA(C;U)1P30A+TDR+TXV | GUH97M070B3M | 16.8 | 13.5 | 8.0 | 7,800 | 210331462 |
| EAH1P30B*+TDR+TXV | GUH92C045B3M | 16.8 | 13.5 | 8.0 | 7,900 | 211734778 |
| EAH1P30B*+TDR+TXV | GUH92C045B3M | 16.8 | 13.5 | 8.0 | 7,900 | 211734780 |
| EAH1P30B*+TDR+TXV | GUH80C070B3M | 16.8 | 13.5 | 8.0 | 7,700 | 211734743 |
| EAH1P30B*+TDR+TXV | GUH80C070B3M | 16.8 | 13.5 | 8.0 | 7,700 | 211734744 |
| EAH1P30B*+TDR+TXV | GUH97M070B3M | 16.8 | 14.0 | 8.0 | 7,800 | 211734879 |
| EAH1P30B*+TDR+TXV | GUH97M070B3M | 16.8 | 14.0 | 8.0 | 7,800 | 211734877 |
| EAH1P30B*+TDR+TXV | GUH92C070B3M | 16.8 | 13.5 | 8.0 | 7,600 | 211734790 |
| EAH1P30B*+TDR+TXV | GUH92C070B3M | 16.8 | 13.5 | 8.0 | 7,600 | 211734789 |
| EA(C;U)1P30A+TDR+TXV | GUH80C045A3M | 16.8 | 13.5 | 7.8 | 7,700 | 210331454 |
| EA(C;U)1P30A+TDR+TXV | GUH80C045A3M | 16.8 | 13.5 | 7.8 | 7,700 | 210330528 |
| EA(C;U)1P30A+TDR+TXV | GUH80C070B3M | 16.8 | 13.5 | 7.8 | 7,700 | 210330529 |
| EA(C;U)1P30A+TDR+TXV | GUH80C070B3M | 16.8 | 13.5 | 7.8 | 7,700 | 210331455 |
| EA(C;U)1P30A+TDR+TXV | GUH92C070B3M | 16.6 | 13.5 | 7.8 | 7,700 | 210330533 |
| EA(C;U)1P30A+TDR+TXV | GUH92C070B3M | 16.6 | 13.5 | 7.8 | 7,700 | 210331459 |
| EA(C;U)1P24A+TDR+TXV | GUH97M070B3M | 16.4 | 13.5 | 8.1 | 8,400 | 210330526 |
| EA(C;U)1P24A+TDR+TXV | GUH97M070B3M | 16.4 | 13.5 | 8.1 | 8,400 | 210331450 |
| EAH1P24B*+TDR+TXV | GUH80C070B3M | 16.4 | 13.5 | 8.1 | 8,200 | 211734524 |
| EAH1P24B*+TDR+TXV | GUH80C070B3M | 16.4 | 13.5 | 8.1 | 8,200 | 211734525 |
| EAH1P24B*+TDR+TXV | GUH92C070B3M | 16.4 | 13.5 | 8.1 | 8,200 | 211734582 |
| EAH1P24B*+TDR+TXV | GUH92C070B3M | 16.4 | 13.5 | 8.1 | 8,200 | 211734581 |
| EAH1P24B*+TDR+TXV | GUH97M070B3M | 16.4 | 13.5 | 8.1 | 8,400 | 211734646 |
| EAH1P24B*+TDR+TXV | GUH97M070B3M | 16.4 | 13.5 | 8.1 | 8,400 | 211734648 |
| EAH1P24B*+TDR+TXV | GUH92C045B3M | 16.4 | 13.5 | 8.1 | 8,200 | 211734565 |
| EAH1P24B*+TDR+TXV | GUH92C045B3M | 16.4 | 13.5 | 8.1 | 8,200 | 211734564 |
| EA(C;U)1P24A+TDR+TXV | GUH80C070A3M | 16.4 | 13.5 | 8.0 | 8,200 | 210331441 |
| EA(C;U)1P24A+TDR+TXV | GUH80C070B3M | 16.4 | 13.5 | 8.0 | 8,200 | 210330519 |
| EA(C;U)1P24A+TDR+TXV | GUH80C070B3M | 16.4 | 13.5 | 8.0 | 8,200 | 210331443 |
| EA(C;U)1P24A+TDR+TXV | GUH80C070A3M | 16.4 | 13.5 | 8.0 | 8,200 | 210330517 |
| EAH1P24A*+TDR+TXV | GUH80C070A3M | 16.4 | 13.5 | 8.0 | 8,000 | 211734369 |
| EAH1P24A*+TDR+TXV | GUH80C070A3M | 16.4 | 13.5 | 8.0 | 8,000 | 211734372 |
| EAH1P24A*+TDR+TXV | GUH80C045A3M | 16.4 | 13.5 | 8.0 | 8,000 | 211734352 |
| EAH1P24A*+TDR+TXV | GUH80C045A3M | 16.4 | 13.5 | 8.0 | 8,000 | 211734353 |
| EA(C;U)1P30A+TDR+TXV | GUH92C045B3M | 16.4 | 13.5 | 7.8 | 7,600 | 210331458 |
| EA(C;U)1P30A+TDR+TXV | GUH92C045B3M | 16.4 | 13.5 | 7.8 | 7,600 | 210330532 |
| EA(C;U)1P30A+TDR+TXV | GUH96C070B3M | 16.4 | 13.5 | 7.8 | 7,700 | 210331457 |
| EA(C;U)1P30A+TDR+TXV | GUH96C070B3M | 16.4 | 13.5 | 7.8 | 7,700 | 210330531 |
| EA(C;U)1P30A+TDR+TXV | GUH96C045B3M | 16.4 | 13.5 | 7.8 | 7,700 | 210331456 |
| EA(C;U)1P30A+TDR+TXV | GUH80C070A3M | 16.4 | 13.5 | 7.8 | 7,700 | 210330527 |
| EA(C;U)1P30A+TDR+TXV | GUH80C070A3M | 16.4 | 13.5 | 7.8 | 7,700 | 210331453 |
| EA(C;U)1P30A+TDR+TXV | GUH96C045B3M | 16.4 | 13.5 | 7.8 | 7,700 | 210330530 |
| EAH1P30B*+TDR+TXV | GUH96C045B3M | 16.4 | 13.5 | 7.8 | 7,700 | 211734823 |
| EAH1P30B*+TDR+TXV | GUH96C045B3M | 16.4 | 13.5 | 7.8 | 7,700 | 211734822 |
| EAH1P30B*+TDR+TXV | GUH96C070B3M | 16.4 | 13.5 | 7.8 | 7,700 | 211734843 |
| EAH1P30B*+TDR+TXV | GUH96C070B3M | 16.4 | 13.5 | 7.8 | 7,700 | 211734845 |
| EA(C;U)1P24A+TDR+TXV | GUH92C070B3M | 16.2 | 13.5 | 8.1 | 8,200 | 210331446 |
| EA(C;U)1P24A+TDR+TXV | GUH92C070B3M | 16.2 | 13.5 | 8.1 | 8,200 | 210330522 |
| EA(C;U)1P24A+TDR+TXV | GUH80C045A3M | 16.2 | 13.5 | 8.0 | 8,200 | 210331442 |
| EA(C;U)1P24A+TDR+TXV | GUH80C045A3M | 16.2 | 13.5 | 8.0 | 8,200 | 210330518 |
| EAH1P24B*+TDR+TXV | GUH96C045B3M | 16.0 | 13.5 | 8.1 | 8,200 | 211734609 |
| EAH1P24B*+TDR+TXV | GUH96C045B3M | 16.0 | 13.5 | 8.1 | 8,200 | 211734610 |
| EAH1P24B*+TDR+TXV | GUH96C070B3M | 16.0 | 13.5 | 8.1 | 8,200 | 211734622 |
| EAH1P24B*+TDR+TXV | GUH96C070B3M | 16.0 | 13.5 | 8.1 | 8,200 | 211734621 |
| EA(C;U)1P24A+TDR+TXV | GUH92C045B3M | 16.0 | 13.5 | 8.0 | 8,200 | 210331445 |
| EA(C;U)1P24A+TDR+TXV | GUH96C045B3M | 16.0 | 13.5 | 8.0 | 8,200 | 210330520 |
| EA(C;U)1P24A+TDR+TXV | GUH96C045B3M | 16.0 | 13.5 | 8.0 | 8,200 | 210331444 |
| EA(C;U)1P24A+TDR+TXV | GUH96C070B3M | 16.0 | 13.5 | 8.0 | 8,200 | 210331447 |
| EA(C;U)1P24A+TDR+TXV | GUH92C045B3M | 16.0 | 13.5 | 8.0 | 8,200 | 210330521 |
| EA(C;U)1P24A+TDR+TXV | GUH96C070B3M | 16.0 | 13.5 | 8.0 | 8,200 | 210330523 |
Yearly running cost in 10 large cities
- Phoenix, AZ$620/yr
- Miami, FL$503/yr
- Houston, TX$556/yr
- Atlanta, GA$562/yr
- Los Angeles, CA$547/yr
- New York, NY$1,342/yr
- Chicago, IL$1,090/yr
- Denver, CO$906/yr
- Seattle, WA$557/yr
- Minneapolis, MN$1,121/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Century HRG1**8S1R-**A?
- The Century HRG1**8S1R-**A is rated at up to 16.8 SEER2 and 13.5 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 64 certified matchups SEER2 ranges from 15.2-16.8.
- Is the Century HRG1**8S1R-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 1.5-ton model.
- How much does the Century HRG1**8S1R-**A cost to run per year?
- At its rated efficiency it costs about $503-$1,342 a year in electricity in large U.S. cities, depending on climate and local rates - for example $620 in Phoenix and $1,121 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Century HRG1**8S1R-**A?
- ENERGY STAR lists 64 certified combinations for this outdoor unit. The highest-rated ones use EA(C;U)1P30A+TDR+TXV, EAH1P30B*+TDR+TXV, EA(C;U)1P24A+TDR+TXV.
- What refrigerant does the Century HRG1**8S1R-**A use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 1.5 ton models
- Blueridge BHP17L18P-**A16.8 SEER2 · 8.4 HSPF2
- MRCOOL MHP17018A-**A16.8 SEER2 · 8.1 HSPF2
- Lennox ML17XP1-018-230A16.8 SEER2 · 8.5 HSPF2
- MRCOOL MVP-18-HP-C-230-2516.6 SEER2 · 10.2 HSPF2
- Lennox EL17XP1-018-230A16.8 SEER2 · 8.5 HSPF2
- Bryant 37MUHAQ18AA3+KSAIC0701230 · cold climate16.5 SEER2 · 9.0 HSPF2
- GE NS17H18SA4-**A16.8 SEER2 · 8.5 HSPF2
- Tempstar D5CUHAH18AAK+KSAIC0701230 · cold climate16.5 SEER2 · 9.0 HSPF2
See all 170 1.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.