HVAC Rated

1.5-ton central heat pump · BHP17L SERIES

Blueridge BHP17L18P-**A

Average cooling efficiency and below average heating efficiency for a 1.5-ton central heat pump, but not rated for cold climates.

Ranks #81 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $549 a year to run in a mixed climate like Atlanta.

SEER2
16.8 Cooling efficiency over a season
Average · beats 45%
HSPF2
8.4 Heating efficiency over a season
Below average · beats 31%
EER2
14.0 Cooling efficiency on a 95°F day
Excellent · beats 98%
Heat at 5°F
9,300 BTU/h44% of its 47°F output
Average · beats 67%

A good fit if…

  • You want a choice of indoor units - 142 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications1.5 ton, R-410A
General
BrandBlueridge
Outdoor unit modelBHP17L18P-**A
SeriesBHP17L SERIES
TypeCentral heat pump
Nominal size1.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceJanuary 5, 2022
Last certifiedMay 27, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.8 (range 15.2-16.8)
EER2Efficiency at 95°F outdoors12.2-14.0
Cooling capacity18,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.4
Capacity at 47°F17,000-18,000 BTU/h
Capacity at 17°F10,400-11,800 BTU/h
Capacity at 5°F7,600-9,300 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.90-2.14
ENERGY STAR cold climateNo
Heating output as it gets colder44% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with BC1P30A+TDR+TXV at the standard test temperatures, in BTU/h:

Certified matchups142 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 142 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
BC1P30A+TDR+TXVBG802UH090BE1216.814.08.07,600210325617
BC4X30B+TDRBG802UH090BE1216.814.08.07,600210441179
BC4X30A+TDRBG802UH070AE1216.813.58.07,600210441174
BC1P30B+TDR+TXVBG802UH090BE1216.814.08.07,600210441140
BC1P30A+TDR+TXVBG802UH070AE1216.813.58.07,600210325602
BH1P30B*+TDR+TXVBG802UH090BE1216.814.08.07,600211734669
BH1P30B*+TDR+TXVBG921UH070BE1216.813.58.07,600211734781
BH1P30B*+TDR+TXVBG921UH045BE1216.813.58.07,900211734769
BH1P30B*+TDR+TXVBG801UH070BE1216.813.58.07,700211734733
BC730HBT-0*+TDRBG802UH090BE1216.814.08.07,600214713279
BC730HBT-0*+TDRBG801UH070BE1216.813.58.07,700214713281
BC730HBT-0*+TDRBG921UH045BE1216.813.58.07,900214713283
BC730CBT-0*+TDRBG802UH090BE1216.814.08.07,600214713313
BC730CAT-0*+TDRBG802UH070AE1216.813.58.07,600214713308
BC730HBT-0*+TDRBG921UH070BE1216.813.58.07,600214713284
BC1P30A+TDR+TXVBG801UH045AE1216.813.57.87,700210325600
BC4X30B+TDRBG801UH070BE1216.813.57.87,700210441182
BC1P30A+TDR+TXVBG801UH070BE1216.813.57.87,700210325606
BC1P30B+TDR+TXVBG801UH070BE1216.813.57.87,700210441143
BC4X30A+TDRBG801UH045AE1216.813.57.87,700210441175
BC730CBT-0*+TDRBG801UH070BE1216.813.57.87,700214713315
BC730CAT-0*+TDRBG801UH045AE1216.813.57.87,700214713309
BC1P30A+TDR+TXVBG802UH070AV1216.613.58.08,000210325604
BC4X30A+TDRBG802UH070AV1216.613.58.08,000210441177
BC730CAT-0*+TDRBG802UH070AV1216.613.58.08,000214713311
BC1P30B+TDR+TXVBG921UH070BE1216.613.57.87,700210441146
BC4X30B+TDRBG921UH070BE1216.613.57.87,700210441185
BC1P30A+TDR+TXVBG921UH070BE1216.613.57.87,700210325615
BC730CBT-0*+TDRBG921UH070BE1216.613.57.87,700214713318
BD4X-30/36B+TDRBG96G1DF045BE1216.413.58.38,700213265504
BC730/36DBT-0*+TDRBG96G1DF045BE1216.413.58.38,700214713289
BC1P24A+TDR+TXVBG802UH070AE1216.413.58.18,200210325571
BC4X24B+TDRBG802UH090BE1216.414.08.18,100210441164
BC4X24A+TDRBG802UH070AE1216.413.58.18,200210441160
BC1P24A+TDR+TXVBG802UH090BE1216.414.08.18,100210325586
BC1P24B+TDR+TXVBG802UH090BE1216.414.08.18,100210441130
BH1P24B*+TDR+TXVBG921UH045BE1216.413.58.18,200211734554
BH1P24B*+TDR+TXVBG802UH090BE1216.413.58.18,200211734431
BH1P24A*+TDR+TXVBG802UH070AE1216.413.58.18,200211734313
BH1P24B*+TDR+TXVBG801UH070BE1216.413.58.18,200211734508
BH1P24B*+TDR+TXVBG921UH070BE1216.413.58.18,200211734566
BC724HBT-0*+TDRBG921UH070BE1216.413.58.18,200214713274
BC724HBT-0*+TDRBG802UH090BE1216.413.58.18,200214713269
BC724HBT-0*+TDRBG801UH070BE1216.413.58.18,200214713271
BC724HBT-0*+TDRBG921UH045BE1216.413.58.18,200214713273
BC724CAT-0*+TDRBG802UH070AE1216.413.58.18,200214713294
BC724HAT-0*+TDRBG802UH070AE1216.413.58.18,200214713265
BC724CBT-0*+TDRBG802UH090BE1216.414.08.18,100214713298
BC1P24A+TDR+TXVBG801UH070AE1216.413.58.08,200210325567
BC1P24A+TDR+TXVBG801UH070BE1216.413.58.08,200210325575
BC4X30B+TDRBG802UH090BV1616.413.58.08,000210441188
BC4X24A+TDRBG801UH070AE1216.413.58.08,200210441162
BC4X24B+TDRBG801UH070BE1216.413.58.08,200210441167
BC1P30B+TDR+TXVBG802UH090BV1616.413.58.08,000210441149
BC1P24B+TDR+TXVBG801UH070BE1216.413.58.08,200210441133
BC1P30A+TDR+TXVBG802UH090BV1616.413.58.08,000210325625
BH1P24A*+TDR+TXVBG801UH045AE1216.413.58.08,000211734336
BH1P24A*+TDR+TXVBG801UH070AE1216.413.58.08,000211734354
BH1P30B*+TDR+TXVBG802UH090BV1616.413.58.08,000211734854
BC730CBT-0*+TDRBG802UH090BV1616.413.58.08,000214713321
Yearly running cost in 10 large cities$503-$1,304

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Blueridge BHP17L18P-**A?
The Blueridge BHP17L18P-**A is rated at up to 16.8 SEER2 and 14.0 EER2 for cooling and up to 8.4 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 142 certified matchups SEER2 ranges from 15.2-16.8.
Is the Blueridge BHP17L18P-**A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 1.5-ton model.
How much does the Blueridge BHP17L18P-**A cost to run per year?
At its rated efficiency it costs about $503-$1,304 a year in electricity in large U.S. cities, depending on climate and local rates - for example $614 in Phoenix and $1,085 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Blueridge BHP17L18P-**A?
ENERGY STAR lists 142 certified combinations for this outdoor unit. The highest-rated ones use BC1P30A+TDR+TXV, BC4X30B+TDR, BC4X30A+TDR.
What refrigerant does the Blueridge BHP17L18P-**A use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $606/yrYou save $309/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Blueridge BHP17L18P-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$606
Current system, per year
$915
You save per year
$309
Payback
22.7 years
Net after 10 years
-$3,914

Cooling $377Heating $229Electricity used: 3,790 kWhSaved vs. a minimum-efficiency heat pump: $93

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 1.5 ton models

See all 170 1.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 27, 2026. How we use the data.