HVAC Rated

1.5-ton central heat pump · MVP-series

MRCOOL MVP-18-HP-C-230-25

Average cooling efficiency and excellent heating efficiency for a 1.5-ton central heat pump, but not rated for cold climates.

Ranks #84 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $493 a year to run in a mixed climate like Atlanta.

SEER2
16.6 Cooling efficiency over a season
Average · beats 42%
HSPF2
10.2 Heating efficiency over a season
Excellent · beats 91%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
- Not reported by the maker

A good fit if…

  • It will heat most of the year - its HSPF2 beats 91% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications1.5 ton, R-410A
General
BrandMRCOOL
Outdoor unit modelMVP-18-HP-C-230-25
SeriesMVP-series
TypeCentral heat pump
Nominal size1.5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceJanuary 1, 2023
Last certifiedFebruary 17, 2025
Cooling
SEER2Seasonal efficiency, higher is better16.6 (range 16.6)
EER2Efficiency at 95°F outdoors11.7
Cooling capacity17,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better10.2
Capacity at 47°F18,000 BTU/h
Capacity at 17°F14,800 BTU/h
Capacity at 5°F-
COP at 5°F2.0 = twice as efficient as a space heater-
ENERGY STAR cold climateNo
Heating output as it gets colder

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with MVP-18-HP-MUAH-230-25 at the standard test temperatures, in BTU/h:

Certified matchups1 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
MVP-18-HP-MUAH-230-2516.611.710.2-211644119
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the MRCOOL MVP-18-HP-C-230-25: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$466-$1,148

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the MRCOOL MVP-18-HP-C-230-25?
The MRCOOL MVP-18-HP-C-230-25 is rated at up to 16.6 SEER2 and 11.7 EER2 for cooling and up to 10.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the MRCOOL MVP-18-HP-C-230-25 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 1.5-ton model.
How much does the MRCOOL MVP-18-HP-C-230-25 cost to run per year?
At its rated efficiency it costs about $466-$1,148 a year in electricity in large U.S. cities, depending on climate and local rates - for example $572 in Phoenix and $945 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the MRCOOL MVP-18-HP-C-230-25 the same as the MRCOOL CENTRAL-18-HP-C-23025?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the MRCOOL MVP-18-HP-C-230-25?
ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses MVP-18-HP-MUAH-230-25.
What refrigerant does the MRCOOL MVP-18-HP-C-230-25 use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $558/yrYou save $335/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump MRCOOL MVP-18-HP-C-230-25
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$558
Current system, per year
$893
You save per year
$335
Payback
19.4 years
Net after 10 years
-$3,152

Cooling $360Heating $198Electricity used: 3,488 kWhSaved vs. a minimum-efficiency heat pump: $129

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 1.5 ton models

See all 170 1.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of February 17, 2025. How we use the data.