3-ton central heat pump · HRG15 SERIES

Comfort-Aire HRG1536S1R-**A

Average cooling and heating efficiency for a 3-ton central heat pump, but not rated for cold climates.

Ranks #177 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,060 a year to run in a mixed climate like Atlanta.

SEER2
16.8 Cooling efficiency over a season
Average · beats 45%
HSPF2
8.7 Heating efficiency over a season
Average · beats 47%
EER2
13.5 Cooling efficiency on a 95°F day
Excellent · beats 95%
Heat at 5°F
19,100 BTU/h50% of its 47°F output
Excellent · beats 92%

A good fit if…

  • You want a choice of indoor units - 243 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications3 ton, R-410A
General
BrandComfort-Aire
Also sold asCentury
Outdoor unit modelHRG1536S1R-**A
SeriesHRG15 SERIES
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceOctober 1, 2022
Last certifiedOctober 27, 2025
Cooling
SEER2Seasonal efficiency, higher is better16.8 (range 15.4-16.8)
EER2Efficiency at 95°F outdoors12.5-13.5
Cooling capacity35,000-36,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.7
Capacity at 47°F32,400-36,000 BTU/h
Capacity at 17°F21,400-23,800 BTU/h
Capacity at 5°F16,800-19,100 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.08-2.34
ENERGY STAR cold climateNo
Heating output as it gets colder50% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 7EC48CX-0*+TDR at the standard test temperatures, in BTU/h:

Certified matchups243 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 243 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
7EC48CX-0*+TDRGUH80C090C5M16.813.57.816,800214713059
7EC48CX-0*+TDRGUH80C090C5M16.813.57.816,800214716883
EAD4X-48C+TDRGDD80C110C5M16.613.08.718,800213265492
EAD4X-48C+TDRGDD80C110C5M16.613.08.718,800213265442
7ED48CX-0*+TDRGDD80C110C5M16.613.08.718,800214713038
7ED48CX-0*+TDRGDD80C110C5M16.613.08.718,800214716862
7EH51CX-0*+TDRGUH80C090C5M16.613.58.017,400214713016
7EH42CX-0*+TDRGUH92C110C4M16.613.58.017,900214712998
7EH42CX-0*+TDRGUH96C110C5M16.613.58.017,800214713001
7EH42CX-0*+TDRGUH96C110C5M16.613.58.017,800214716825
7EH51CX-0*+TDRGUH80C090C5M16.613.58.017,400214716840
7EH42CX-0*+TDRGUH92C110C4M16.613.58.017,900214716822
7EC48CX-0*+TDRGUH80C110C5M16.613.58.017,000214716884
7EC48CX-0*+TDRGUH80C110C5M16.613.58.017,000214713060
EA(C;U)1P36B+TDR+TXVGUH80C090B4M16.613.57.816,800210421098
EA(C;U)1P36B+TDR+TXVGUH80C090B4M16.613.57.816,800210421177
EA(C;U)1P36A+TDR+TXVGUH80C090B4M16.613.57.816,800210330417
EA(C;U)1P36A+TDR+TXVGUH80C090B4M16.613.57.816,800210331325
7EC48CX-0*+TDRGUH96C090C4M16.613.57.817,000214713065
7EC48CX-0*+TDRGUH92C090C4M16.613.57.816,800214713062
7EC48CX-0*+TDRGUH92C110C4M16.613.57.817,000214713063
7EC48CX-0*+TDRGUH92C110C5M16.613.57.816,800214713064
7EC48CX-0*+TDRGUH96C110C5M16.613.57.817,000214713066
7EC36BX-0*+TDRGUH80C090B4M16.613.57.816,800214713050
7EC36BX-0*+TDRGUH80C090B4M16.613.57.816,800214716874
7EC48CX-0*+TDRGUH92C090C4M16.613.57.816,800214716886
7EC48CX-0*+TDRGUH92C110C4M16.613.57.817,000214716887
7EC48CX-0*+TDRGUH92C110C5M16.613.57.816,800214716888
7EC48CX-0*+TDRGUH96C090C4M16.613.57.817,000214716889
7EC48CX-0*+TDRGUH96C110C5M16.613.57.817,000214716890
7EH42BX-0*+TDRGUH80C090B4M16.413.08.118,300214712987
7EH51CX-0*+TDRGUH80C110C5M16.413.08.117,400214713017
7EH42CX-0*+TDRGUH80C110C5M16.413.58.118,000214712995
7EH51CX-0*+TDRGUH80C110C5M16.413.08.117,400214716841
7EH42BX-0*+TDRGUH80C090B4M16.413.08.118,300214716811
7EH42CX-0*+TDRGUH80C110C5M16.413.58.118,000214716819
7EH42CX-0*+TDRGUH80C090C5M16.413.58.017,900214712994
7EH51CX-0*+TDRGUH92C110C5M16.413.08.017,300214713021
7EH51CX-0*+TDRGUH96C110C5M16.413.08.017,500214713023
7EH42CX-0*+TDRGUH92C090C4M16.413.58.017,900214712997
7EH42CX-0*+TDRGUH97M090C4M16.413.58.018,000214713003
7EH42CX-0*+TDRGUH92C110C5M16.413.58.017,900214712999
7EH42CX-0*+TDRGUH96C090C4M16.413.58.018,100214713000
7EH51CX-0*+TDRGUH92C110C5M16.413.08.017,300214716845
7EH51CX-0*+TDRGUH96C110C5M16.413.08.017,500214716847
7EH42CX-0*+TDRGUH80C090C5M16.413.58.017,900214716818
7EH42CX-0*+TDRGUH97M090C4M16.413.58.018,000214716827
7EH42CX-0*+TDRGUH92C090C4M16.413.58.017,900214716821
7EH42CX-0*+TDRGUH92C110C5M16.413.58.017,900214716823
7EH42CX-0*+TDRGUH96C090C4M16.413.58.018,100214716824
EA(C;U)1P50/60C+TDR+TXVGUH80C090C5M16.413.07.817,000210330418
7EC48CX-0*+TDRGUH92C090C3M16.413.57.817,000214713061
7EC48CX-0*+TDRGUH97M090C4M16.413.57.817,000214713068
7EC48CX-0*+TDRGUH97M110C5M16.413.57.817,200214713070
7EC50/60CX-0*+TDRGUH80C090C5M16.413.07.817,000214713073
7EH51CX-0*+TDRGUH92C110C4M16.413.07.817,400214713020
7EH51CX-0*+TDRGUH92C110C4M16.413.07.817,400214716844
7EC48CX-0*+TDRGUH97M090C4M16.413.57.817,000214716892
7EC48CX-0*+TDRGUH97M110C5M16.413.57.817,200214716894
7EC50/60CX-0*+TDRGUH80C090C5M16.413.07.817,000214716897
Yearly running cost in 10 large cities$1,004-$2,488

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Comfort-Aire HRG1536S1R-**A?
The Comfort-Aire HRG1536S1R-**A is rated at up to 16.8 SEER2 and 13.5 EER2 for cooling and up to 8.7 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 243 certified matchups SEER2 ranges from 15.4-16.8.
Is the Comfort-Aire HRG1536S1R-**A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
How much does the Comfort-Aire HRG1536S1R-**A cost to run per year?
At its rated efficiency it costs about $1,004-$2,488 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,210 in Phoenix and $2,058 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Comfort-Aire HRG1536S1R-**A?
ENERGY STAR lists 243 certified combinations for this outdoor unit. The highest-rated ones use 7EC48CX-0*+TDR, EAD4X-48C+TDR, 7ED48CX-0*+TDR.
What refrigerant does the Comfort-Aire HRG1536S1R-**A use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,187/yrYou save $630/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Comfort-Aire HRG1536S1R-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,187
Current system, per year
$1,817
You save per year
$630
Payback
21.4 years
Net after 10 years
-$7,199

Cooling $754Heating $433Electricity used: 7,418 kWhSaved vs. a minimum-efficiency heat pump: $201

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.