5-ton central heat pump · SoftSound 23 VS Heat Pump

Comfortmaker C5H3V60*K*AAA

Excellent cooling efficiency and below average heating efficiency for a 5-ton central heat pump, and certified for cold climates.

Ranks #7 of 100 5 ton central heat pumps for cooling efficiency, and costs about $1,743 a year to run in a mixed climate like Atlanta.

SEER2
20.0 Cooling efficiency over a season
Excellent · beats 94%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
12.5 Cooling efficiency on a 95°F day
Very good · beats 80%
Heat at 5°F
47,500 BTU/h74% of its 47°F output
Average · beats 53%

A good fit if…

  • You want low cooling bills - its SEER2 beats 94% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 47,500 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 165 certified pairings.

Think twice if…

  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications5 ton, R-454B
General
BrandComfortmaker
Also sold asDay & Night, Keeprite
Outdoor unit modelC5H3V60*K*AAA
SeriesSoftSound 23 VS Heat Pump
TypeCentral heat pump
Nominal size5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 1, 2024
Last certifiedJuly 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better20.0 (range 17.0-20.0)
EER2Efficiency at 95°F outdoors10.5-12.5
Cooling capacity55,000-58,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F60,000-63,500 BTU/h
Capacity at 17°F46,000-49,000 BTU/h
Capacity at 5°F41,000-47,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.95-2.08
ENERGY STAR cold climateYes
Heating output as it gets colder74% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FCMA5B60L0D*+WALLCON at the standard test temperatures, in BTU/h:

Certified matchups165 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 165 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FCMA5B60L0D*+WALLCON · cold climate-20.012.58.544,500215931491
FCMA5B60L0D*+WALLCON · cold climate-20.012.58.544,500215931492
FCMA5B60L0D*+WALLCON · cold climate-20.012.58.544,500215931493
EA*5X60M24A*+WALLCON · cold climate*80CSU0802120A*19.011.58.545,500215931519
EA*5X60M24A*+WALLCON · cold climate*80CSU0802120A*19.011.58.545,500215931520
EA*5X60M24A*+WALLCON · cold climate*80CSU0802120A*19.011.58.545,500215931521
EA*5X61M24A*+WALLCON · cold climate*80CSU0802120A*19.011.58.546,000215931669
EA*5X61M24A*+WALLCON · cold climate*80CSU0802120A*19.011.58.546,000215931670
EA*5X61M24A*+WALLCON · cold climate*80CSU0802120A*19.011.58.546,000215931671
EA*5X61M24A*+WALLCON · cold climate*80CSU1002120A*19.011.08.546,500215931679
EA*5X61M24A*+WALLCON · cold climate*80CSU1002120A*19.011.08.546,500215931680
EA*5X61M24A*+WALLCON · cold climate*80CSU1002120A*19.011.08.546,500215931681
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.011.58.546,500215931700
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.011.58.546,500215931699
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.011.58.546,500215931701
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.011.58.546,500215931709
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.011.58.546,500215931710
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.011.58.546,500215931711
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*19.011.78.546,000215931719
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*19.011.78.546,000215931720
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*19.011.78.546,000215931721
EA*5X60M24A*+WALLCON · cold climate*80CSU1002120A*18.511.08.546,000215931529
EA*5X60M24A*+WALLCON · cold climate*80CSU1002120A*18.511.08.546,000215931530
EA*5X60M24A*+WALLCON · cold climate*80CSU1002120A*18.511.08.546,000215931531
EA*5X60M24A*+WALLCON · cold climate*80CTL0902120B*18.511.58.545,500215931549
EA*5X60M24A*+WALLCON · cold climate*80CTL0902120B*18.511.58.545,500215931551
EA*5X60M24A*+WALLCON · cold climate*80CTL0902120B*18.511.58.545,500215931550
EA*5X60M24A*+WALLCON · cold climate*97CMN1002122B*18.511.08.546,000215931619
EA*5X60M24A*+WALLCON · cold climate*97CMN1002122B*18.511.08.546,000215931621
EA*5X60M24A*+WALLCON · cold climate*97CMN1002122B*18.511.08.546,000215931620
EA*5X60M24A*+WALLCON · cold climate*97CMN1202422B*18.511.08.546,000215931630
EA*5X60M24A*+WALLCON · cold climate*97CMN1202422B*18.511.08.546,000215931629
EA*5X60M24A*+WALLCON · cold climate*97CMN1202422B*18.511.08.546,000215931631
EA*5X60M24A*+WALLCON · cold climate*96CTN1002122B*18.511.08.546,000215931639
EA*5X60M24A*+WALLCON · cold climate*96CTN1002122B*18.511.08.546,000215931641
EA*5X60M24A*+WALLCON · cold climate*96CTN1002122B*18.511.08.546,000215931640
EA*5X60M24A*+WALLCON · cold climate*96CTN1202422B*18.511.08.546,000215931650
EA*5X60M24A*+WALLCON · cold climate*96CTN1202422B*18.511.08.546,000215931649
EA*5X60M24A*+WALLCON · cold climate*96CTN1202422B*18.511.08.546,000215931651
EA*5X60M24A*+WALLCON · cold climate*80CTL1102120B*18.511.58.545,500215931559
EA*5X60M24A*+WALLCON · cold climate*80CTL1102120B*18.511.58.545,500215931561
EA*5X60M24A*+WALLCON · cold climate*80CTL1102120B*18.511.58.545,500215931560
EA*5X60M24A*+WALLCON · cold climate*80CTL1352422B*18.511.58.545,500215931569
EA*5X60M24A*+WALLCON · cold climate*80CTL1352422B*18.511.58.545,500215931570
EA*5X60M24A*+WALLCON · cold climate*80CTL1352422B*18.511.58.545,500215931571
EA*5X60M24A*+WALLCON · cold climate*95CSU1002122B*18.511.58.545,500215931589
EA*5X60M24A*+WALLCON · cold climate*95CSU1002122B*18.511.58.545,500215931591
EA*5X60M24A*+WALLCON · cold climate*95CSU1002122B*18.511.58.545,500215931590
EA*5X61M24A*+WALLCON · cold climate*80CTL0702120B*18.511.08.547,000215931689
EA*5X61M24A*+WALLCON · cold climate*80CTL0702120B*18.511.08.547,000215931690
EA*5X61M24A*+WALLCON · cold climate*80CTL0702120B*18.511.08.547,000215931691
EA*5X61M24A*+WALLCON · cold climate*95CSU0802120B*18.511.08.546,500215931729
EA*5X61M24A*+WALLCON · cold climate*95CSU0802120B*18.511.08.546,500215931730
EA*5X61M24A*+WALLCON · cold climate*95CSU0802120B*18.511.08.546,500215931731
EA*5X61M24A*+WALLCON · cold climate*97CMN0802120B*18.511.08.546,500215931750
EA*5X61M24A*+WALLCON · cold climate*97CMN0802120B*18.511.08.546,500215931749
EA*5X61M24A*+WALLCON · cold climate*97CMN0802120B*18.511.08.546,500215931751
EA*5X61M24A*+WALLCON · cold climate*97CMN1002122B*18.511.58.546,500215931760
EA*5X61M24A*+WALLCON · cold climate*97CMN1002122B*18.511.58.546,500215931761
EA*5X61M24A*+WALLCON · cold climate*97CMN1002122B*18.511.58.546,500215931759
Yearly running cost in 10 large cities$1,340-$4,344

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Comfortmaker C5H3V60*K*AAA?
The Comfortmaker C5H3V60*K*AAA is rated at up to 20.0 SEER2 and 12.5 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 165 certified matchups SEER2 ranges from 17.0-20.0.
Is the Comfortmaker C5H3V60*K*AAA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 47,500 BTU/h at 5°F with a COP of 2.08, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
How much does the Comfortmaker C5H3V60*K*AAA cost to run per year?
At its rated efficiency it costs about $1,340-$4,344 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,757 in Phoenix and $3,711 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Comfortmaker C5H3V60*K*AAA?
ENERGY STAR lists 165 certified combinations for this outdoor unit. The highest-rated ones use FCMA5B60L0D*+WALLCON, EA*5X60M24A*+WALLCON, EA*5X61M24A*+WALLCON.
What refrigerant does the Comfortmaker C5H3V60*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,798/yrYou save $1,189/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Comfortmaker C5H3V60*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,798
Current system, per year
$2,987
You save per year
$1,189
Payback
17.7 years
Net after 10 years
-$9,113

Cooling $994Heating $804Electricity used: 11,239 kWhSaved vs. a minimum-efficiency heat pump: $504

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 5 ton models

See all 100 5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 16, 2026. How we use the data.