HVAC Rated

2-ton central heat pump · 7SCP18V Series

Concord 7SCP18V24P-**A

Very good cooling and heating efficiency for a 2-ton central heat pump, and certified for cold climates.

Ranks #88 of 331 2 ton central heat pumps for cooling efficiency, and costs about $652 a year to run in a mixed climate like Atlanta.

SEER2
18.5 Cooling efficiency over a season
Very good · beats 77%
HSPF2
10.0 Heating efficiency over a season
Very good · beats 84%
EER2
12.3 Cooling efficiency on a 95°F day
Very good · beats 76%
Heat at 5°F
23,400 BTU/h92% of its 47°F output
Below average · beats 12%

A good fit if…

  • You want low cooling bills - its SEER2 beats 77% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 23,400 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandConcord
Also sold asDucane, ALLIED
Outdoor unit model7SCP18V24P-**A
Series7SCP18V Series
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceOctober 29, 2024
Last certifiedJuly 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better18.5 (range 15.2-18.5)
EER2Efficiency at 95°F outdoors11.0-12.3
Cooling capacity23,200-24,200 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-10.0
Capacity at 47°F23,800-24,800 BTU/h
Capacity at 17°F18,000-20,200 BTU/h
Capacity at 5°F20,000-23,400 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.75-1.85
ENERGY STAR cold climateYes
Heating output as it gets colder92% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 7AH2AE30PX- at the standard test temperatures, in BTU/h:

Certified matchups390 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 390 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
7AH2AE30PX- · cold climate-18.512.39.822,000216705399
7AH2AE30PX- · cold climate-18.512.39.822,000216705392
7AH2AE30PX- · cold climate-18.512.39.822,000217509116
7AH1AV24PX- · cold climate-18.011.710.023,000216013464
7AH1AV24PX- · cold climate-18.011.710.023,000216013468
7AH1AV24PX- · cold climate-18.011.710.023,000217509071
7AH1RE30DX- · cold climate-17.911.89.922,600218636364
7AH1RE18DX- · cold climate-17.911.99.922,600218636362
7AH1RE30DX- · cold climate-17.911.89.922,600218636355
7AH1RE18DX- · cold climate-17.911.99.922,600218636353
7AH1RE30DX- · cold climate-17.911.89.922,600218636346
7AH1RE18DX- · cold climate-17.911.99.922,600218636344
7EH30AX-**+TDR · cold climate80G2UH045AE12*17.912.09.520,600217189189
7EH30AX-**+TDR · cold climate80G2UH045AE12*17.912.09.520,600217189449
7EH30AX-**+TDR · cold climate80G2UH045AE12*17.912.09.520,600217509208
7AH1RE24DX- · cold climate-17.811.89.922,600218636363
7AH1RE24DX- · cold climate-17.811.89.922,600218636354
7AH1RE24DX- · cold climate-17.811.89.922,600218636345
7E[C,U]36AX-**+TDR · cold climate80G2UH045AE12*17.812.09.420,600217189410
7E[C,U]36AX-**+TDR · cold climate80G2UH045AE12*17.812.09.420,600217189150
7E[C,U]36AX-**+TDR · cold climate80G2UH045AE12*17.812.09.420,600217509178
7EH30AX-**+TDR · cold climate80G1UH040AE12X*17.611.79.520,800217189445
7EH30AX-**+TDR · cold climate80G1UH060AE12X*17.611.79.521,000217189446
7EH30AX-**+TDR · cold climate80G1UH040AE12X*17.611.79.520,800217189185
7EH30AX-**+TDR · cold climate80G1UH060AE12X*17.611.79.521,000217189186
7EH30AX-**+TDR · cold climate80G1UH040AE12X*17.611.79.520,800217509204
7EH30AX-**+TDR · cold climate80G1UH060AE12X*17.611.79.521,000217509205
7AH1AE24PX- · cold climate-17.512.09.523,000216619071
7AH1AE24PX- · cold climate-17.512.09.523,000216619120
7AH1AE24PX- · cold climate-17.512.09.523,000217509081
7AH1AV18PX- · cold climate-17.511.79.423,400216619069
7AH1AE30PX- · cold climate-17.512.09.423,200216619072
7AH1AV30PX- · cold climate-17.512.09.423,200216619073
7AH1AV18PX- · cold climate-17.511.79.423,400216619118
7AH1AE30PX- · cold climate-17.512.09.423,200216619121
7AH1AV30PX- · cold climate-17.512.09.423,200216619122
7AH1AV18PX- · cold climate-17.511.79.423,400217509080
7AH1AE30PX- · cold climate-17.512.09.423,200217509082
7AH1AV30PX- · cold climate-17.512.09.423,200217509083
7EH24BX-**+TDR · cold climate97G2UH070BV12*17.512.09.020,800216769669
7E[C,U]36BX-**+TDR · cold climate97G2UH070BV12*17.512.09.020,600216769665
7E[C,U]36BX-**+TDR · cold climate97G2UH070BV12*17.512.09.020,600216769666
7EH24BX-**+TDR · cold climate97G2UH070BV12*17.512.09.020,800216769670
7E[C,U]36AX-**+TDR · cold climate80G1UH040AE12X*17.511.79.020,800217189146
7E[C,U]36AX-**+TDR · cold climate80G1UH060AE12X*17.511.79.020,800217189147
7E[C,U]30AX-**+TDR · cold climate80G2UH045AE12*17.512.09.020,600217189395
7E[C,U]30AX-**+TDR · cold climate80G2UH045AE12*17.512.09.020,600217189135
7E[C,U]36AX-**+TDR · cold climate80G1UH040AE12X*17.511.79.020,800217189406
7E[C,U]36AX-**+TDR · cold climate80G1UH060AE12X*17.511.79.020,800217189407
7E[C,U]36AX-**+TDR · cold climate80G1UH040AE12X*17.511.79.020,800217509174
7E[C,U]30AX-**+TDR · cold climate80G2UH045AE12*17.512.09.020,600217509163
7E[C,U]36BX-**+TDR · cold climate97G2UH070BV12*17.512.09.020,600217509125
7E[C,U]36AX-**+TDR · cold climate80G1UH060AE12X*17.511.79.020,800217509175
7EH24BX-**+TDR · cold climate97G2UH070BV12*17.512.09.020,800217509127
7EH30AX-**+TDR · cold climate80G1UH045AE12*17.411.79.520,800217189191
7EH30AX-**+TDR · cold climate80G1UH045AE12*17.411.79.520,800217189451
7EH30AX-**+TDR · cold climate80G1UH045AE12L*17.411.79.520,800217189452
7EH30AX-**+TDR · cold climate80G1UH045AE12L*17.411.79.520,800217189192
7EH30AX-**+TDR · cold climate80G1UH045AE12*17.411.79.520,800217509210
7EH30AX-**+TDR · cold climate80G1UH045AE12L*17.411.79.520,800217509211
Yearly running cost in 10 large cities$608-$1,538

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Concord 7SCP18V24P-**A?
The Concord 7SCP18V24P-**A is rated at up to 18.5 SEER2 and 12.3 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 390 certified matchups SEER2 ranges from 15.2-18.5.
Is the Concord 7SCP18V24P-**A good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 23,400 BTU/h at 5°F with a COP of 1.85, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
How much does the Concord 7SCP18V24P-**A cost to run per year?
At its rated efficiency it costs about $608-$1,538 a year in electricity in large U.S. cities, depending on climate and local rates - for example $738 in Phoenix and $1,275 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Concord 7SCP18V24P-**A?
ENERGY STAR lists 390 certified combinations for this outdoor unit. The highest-rated ones use 7AH2AE30PX-, 7AH1AV24PX-, 7AH1RE30DX-.
What refrigerant does the Concord 7SCP18V24P-**A use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $725/yrYou save $512/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Concord 7SCP18V24P-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$725
Current system, per year
$1,238
You save per year
$512
Payback
17.6 years
Net after 10 years
-$3,879

Cooling $457Heating $269Electricity used: 4,534 kWhSaved vs. a minimum-efficiency heat pump: $224

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 16, 2026. How we use the data.