3-ton central heat pump · CH Series
Cooper&Hunter CH-PQ36X-230VO
Average cooling efficiency and very good heating efficiency for a 3-ton central heat pump, and certified for cold climates.
Ranks #97 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,022 a year to run in a mixed climate like Atlanta.
- SEER2
- 18.0 Cooling efficiency over a seasonAverage · beats 66%
- HSPF2
- 10.0 Heating efficiency over a seasonVery good · beats 84%
- EER2
- 12.0 Cooling efficiency on a 95°F dayAverage · beats 64%
- Heat at 5°F
- 37,400 BTU/h101% of its 47°F outputBelow average · beats 20%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 37,400 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Cooper&Hunter |
| Outdoor unit model | CH-PQ36X-230VO |
| Series | CH Series |
| Type | Central heat pump |
| Nominal size | 3 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | September 9, 2025 |
| Last certified | June 29, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 18.0 (range 15.8-18.0) |
| EER2Efficiency at 95°F outdoors | 10.7-12.0 |
| Cooling capacity | 36,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.4-10.0 |
| Capacity at 47°F | 37,000-38,000 BTU/h |
| Capacity at 17°F | 29,200-33,000 BTU/h |
| Capacity at 5°F | 34,600-37,400 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80-1.90 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CH-PQ36AHU at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| CH-PQ36AHU · cold climate | 18.0 | 12.0 | 10.0 | 37,400 | 217902701 |
| CH-STM36AHU24V · cold climate | 16.8 | 11.2 | 9.6 | 34,600 | 218470848 |
| CH-ACL30-36C · cold climate | 15.8 | 10.7 | 9.4 | 36,000 | 217732886 |
| CH-ACL30-36B · cold climate | 15.8 | 10.7 | 9.4 | 36,000 | 217732885 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,145/yr
- Miami, FL$938/yr
- Houston, TX$1,026/yr
- Atlanta, GA$1,022/yr
- Los Angeles, CA$991/yr
- New York, NY$2,422/yr
- Chicago, IL$1,963/yr
- Denver, CO$1,629/yr
- Seattle, WA$998/yr
- Minneapolis, MN$2,014/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Cooper&Hunter CH-PQ36X-230VO?
- The Cooper&Hunter CH-PQ36X-230VO is rated at up to 18.0 SEER2 and 12.0 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 4 certified matchups SEER2 ranges from 15.8-18.0.
- Is the Cooper&Hunter CH-PQ36X-230VO good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 37,400 BTU/h at 5°F with a COP of 1.90, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
- How much does the Cooper&Hunter CH-PQ36X-230VO cost to run per year?
- At its rated efficiency it costs about $938-$2,422 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,145 in Phoenix and $2,014 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Cooper&Hunter CH-PQ36X-230VO?
- ENERGY STAR lists 4 certified combinations for this outdoor unit. The highest-rated ones use CH-PQ36AHU, CH-STM36AHU24V, CH-ACL30-36C.
- What refrigerant does the Cooper&Hunter CH-PQ36X-230VO use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3 ton models
- 1HVAC ACIQ-36-HP32 · cold climate18.0 SEER2 · 10.0 HSPF2
- MDV MOE30-36HFN10-M3X · cold climate18.0 SEER2 · 10.0 HSPF2
- NOVAIR LEA36CEN36-O · cold climate18.0 SEER2 · 10.3 HSPF2
- MRCOOL UHP18036-O · cold climate18.0 SEER2 · 10.0 HSPF2
- MOOVAIR MSHMB36R2AN1 · cold climate18.0 SEER2 · 10.3 HSPF2
- TOSOT TU36-32WEDU · cold climate18.0 SEER2 · 10.0 HSPF2
- Midea MO1SE-H36B-2A · cold climate18.0 SEER2 · 10.3 HSPF2
- UTL UCHA-36HDCTRN2 · cold climate18.0 SEER2 · 10.0 HSPF2
See all 302 3 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 29, 2026. How we use the data.