HVAC Rated

4-ton central heat pump · DH9VSA

Daikin DH9VSA6010A

Average cooling and heating efficiency for a 4-ton central heat pump, and certified for cold climates.

Ranks #93 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,551 a year to run in a mixed climate like Atlanta.

SEER2
18.0 Cooling efficiency over a season
Average · beats 66%
HSPF2
9.0 Heating efficiency over a season
Average · beats 54%
EER2
10.5 Cooling efficiency on a 95°F day
Below average · beats 17%
Heat at 5°F
47,000 BTU/h87% of its 47°F output
Below average · beats 20%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 47,000 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 33 certified pairings.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications4 ton, R-32
General
BrandDaikin
Also sold asGoodman, Amana
Outdoor unit modelDH9VSA6010A
SeriesDH9VSA
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-32
Connected (smart) capableYes
On the market sinceNovember 17, 2025
Last certifiedOctober 7, 2026
Cooling
SEER2Seasonal efficiency, higher is better18.0 (range 15.2-18.0)
EER2Efficiency at 95°F outdoors9.8-10.5
Cooling capacity52,000-54,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-9.0
Capacity at 47°F52,500-54,000 BTU/h
Capacity at 17°F33,400 BTU/h
Capacity at 5°F45,000-47,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80-1.90
ENERGY STAR cold climateYes
Heating output as it gets colder87% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with DFVE60DP1300A at the standard test temperatures, in BTU/h:

Certified matchups33 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
DFVE60DP1300A · cold climate-18.010.59.047,000217989105
DFVE60DP0300A · cold climate-18.010.59.047,000217989110
CA*EA6030*3A*+MBVK20DP1X00A · cold climate-17.09.88.846,000217989112
CA*EA6030*3A*+MBVK16CP1X00A · cold climate-17.09.88.846,000217989114
CA*EA6030*3A · cold climateD*80TC1005C*A*17.09.88.846,000217989124
CA*EA6030*3A · cold climateD*80TC0805D*A*17.09.88.846,000217989126
CA*EA6030*3A · cold climateD*80TC0805C*A*17.09.88.846,000217989128
CA*EA6030*3A · cold climateD*80TC0804C*A*17.09.88.846,000217989130
CA*EA6030*3A · cold climateD*80SC0805CUA*17.09.88.846,000217989134
CAHEA3630C3A*+MBVK16CH*X00A · cold climate-17.09.88.846,000217989139
CA*EA6030*3A · cold climateD*96TC0804CNA*16.59.88.846,000217989122
CA*EA6030*3A · cold climateD*96SC0805CUA*16.59.88.846,000217989132
CA*EA6030*3A · cold climateD*97MC1005CNA*16.59.88.846,000217989138
CA*EA6030*3A · cold climateD*96TC1005CNA*16.59.88.546,000217989120
CHPEA6030*3A*+MBVK20DP1X00A · cold climate-16.09.88.545,000217989111
CHPEA6030*3A*+MBVK16CP1X00A · cold climate-16.09.88.545,000217989113
CHPEA6030*3A · cold climateD*96TC1205DNA*16.09.88.545,000217989115
CA*EA6030*3A · cold climateD*96TC1205DNA*16.09.88.546,000217989116
CHPEA6030*3A · cold climateD*96TC1005DNA*16.09.88.545,000217989117
CA*EA6030*3A · cold climateD*96TC1005DNA*16.09.88.546,000217989118
CHPEA6030*3A · cold climateD*80TC0805D*A*16.09.88.545,000217989125
CHPEA6030*3A · cold climateD*80TC1005C*A*16.09.88.545,000217989123
CHPEA6030*3A · cold climateD*80TC0805C*A*16.09.88.545,000217989127
CHPEA6030*3A · cold climateD*97MC1205DNA*16.09.88.545,000217989135
CA*EA6030*3A · cold climateD*97MC1205DNA*16.09.88.546,000217989136
CHPEA6030*3A · cold climateD*80TC0804C*A*16.09.88.545,000217989129
CHPEA6030*3A · cold climateD*80SC0805CUA*16.09.88.545,000217989133
CA*EA6030*3A · cold climateD*96VC1205DNA*16.09.88.546,000218003033
CHPEA6030*3A · cold climateD*96VC1205DNA*16.09.88.545,000218003032
CHPEA6030*3A · cold climateD*96TC1005CNA*15.59.88.545,000217989119
CHPEA6030*3A · cold climateD*96SC0805CUA*15.59.88.545,000217989131
CHPEA6030*3A · cold climateD*97MC1005CNA*15.59.88.545,000217989137
CHPEA6030*3A · cold climateD*96TC0804CNA*15.29.88.545,000217989121
Same unit, other model numbers2

These model numbers have exactly the same certified ratings and matchups as the Daikin DH9VSA6010A: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$1,359-$3,731

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Daikin DH9VSA6010A?
The Daikin DH9VSA6010A is rated at up to 18.0 SEER2 and 10.5 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 33 certified matchups SEER2 ranges from 15.2-18.0.
Is the Daikin DH9VSA6010A good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 47,000 BTU/h at 5°F with a COP of 1.90, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
How much does the Daikin DH9VSA6010A cost to run per year?
At its rated efficiency it costs about $1,359-$3,731 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,689 in Phoenix and $3,127 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Daikin DH9VSA6010A the same as the Goodman GZV9SA6010A?
Yes, as far as the certified ratings go. ENERGY STAR lists 3 model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Daikin DH9VSA6010A?
ENERGY STAR lists 33 certified combinations for this outdoor unit. The highest-rated ones use DFVE60DP1300A, DFVE60DP0300A, CA*EA6030*3A*+MBVK20DP1X00A.
What refrigerant does the Daikin DH9VSA6010A use?
It uses R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,683/yrYou save $1,023/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Daikin DH9VSA6010A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,683
Current system, per year
$2,706
You save per year
$1,023
Payback
19.1 years
Net after 10 years
-$9,269

Cooling $1,017Heating $666Electricity used: 10,517 kWhSaved vs. a minimum-efficiency heat pump: $396

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 7, 2026. How we use the data.