4-ton central heat pump · Connect
Haier 1U60T3PE*HE
Average cooling efficiency and very good heating efficiency for a 4-ton central heat pump, and certified for cold climates.
Ranks #88 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,333 a year to run in a mixed climate like Atlanta.
- SEER2
- 18.0 Cooling efficiency over a seasonAverage · beats 66%
- HSPF2
- 9.5 Heating efficiency over a seasonVery good · beats 70%
- EER2
- 11.7 Cooling efficiency on a 95°F dayAverage · beats 43%
- Heat at 5°F
- 43,000 BTU/h88% of its 47°F outputBelow average · beats 27%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 43,000 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 191 certified pairings.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Haier |
| Outdoor unit model | 1U60T3PE*HE |
| Series | Connect |
| Type | Central heat pump |
| Nominal size | 4 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | October 16, 2024 |
| Last certified | January 20, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 18.0 (range 15.2-18.0) |
| EER2Efficiency at 95°F outdoors | 9.6-11.7 |
| Cooling capacity | 42,500-55,500 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.1-9.5 |
| Capacity at 47°F | 47,500-56,000 BTU/h |
| Capacity at 17°F | 38,000-45,000 BTU/h |
| Capacity at 5°F | 39,000-43,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.75-1.95 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with NAM48V1TA5 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 191 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| NAM48V1TA5 · cold climate | - | 18.0 | 11.7 | 9.5 | 42,000 | 217269591 |
| NAM42V2TA5 · cold climate | - | 18.0 | 11.0 | 9.5 | 42,500 | 217270183 |
| NCUC49CT5****+TDR · cold climate | NF80U110V5C*** | 17.7 | 11.0 | 9.0 | 39,000 | 217270501 |
| NAM42E1TA5 · cold climate | - | 17.6 | 10.5 | 9.0 | 43,000 | 217270180 |
| NAM42V1TA5 · cold climate | - | 17.6 | 11.0 | 9.0 | 43,000 | 217270181 |
| NAM48V2TA5 · cold climate | - | 17.5 | 10.5 | 9.0 | 43,000 | 217270184 |
| NAM48E1TA5 · cold climate | - | 17.5 | 11.0 | 9.0 | 43,000 | 217270182 |
| NCUC49CT5****+TDR · cold climate | NF80X080V4B*** | 17.5 | 11.0 | 9.0 | 39,000 | 217270502 |
| NCUC49CT5****+TDR · cold climate | NF80X100V5C*** | 17.5 | 11.0 | 9.0 | 39,000 | 217270503 |
| NCUC49CT5****+TDR · cold climate | NF98U110M5C*** | 17.4 | 11.0 | 9.0 | 39,000 | 217270509 |
| NCDC48CT5****+TDR · cold climate | NF96D090S4C*** | 17.3 | 10.0 | 9.0 | 39,000 | 217270544 |
| NCUC49CT5****+TDR · cold climate | NF97X080V5C*** | 17.3 | 11.0 | 9.0 | 39,500 | 217270268 |
| NCUC49CT5****+TDR · cold climate | NF96U110V5C*** | 17.2 | 10.0 | 9.0 | 39,500 | 217270634 |
| NCUC49CT5****+TDR · cold climate | NF97U110V5C*** | 17.2 | 10.0 | 9.0 | 39,500 | 217270269 |
| NCUC49CT5****+TDR · cold climate | NF80U090S5C*** | 17.2 | 11.0 | 9.0 | 39,500 | 217270507 |
| NCUC49CT5****+TDR · cold climate | NF80U110S5C*** | 17.2 | 10.0 | 9.0 | 39,500 | 217270508 |
| NCDC48CT5****+TDR · cold climate | NF80D110S5C*** | 17.2 | 11.0 | 9.0 | 39,000 | 217270545 |
| NCUC60CT5****+TDR · cold climate | NF80U090S5C*** | 17.2 | 10.0 | 8.5 | 40,500 | 217270553 |
| NCUC60CT5****+TDR · cold climate | NF80U110S5C*** | 17.2 | 10.0 | 8.5 | 40,500 | 217270554 |
| NCDC48CT5****+TDR · cold climate | NF97D090M4C*** | 17.1 | 10.0 | 9.0 | 39,500 | 217270543 |
| NCUC49CT5****+TDR · cold climate | NF96U090V5C*** | 17.1 | 10.0 | 9.0 | 39,500 | 217270635 |
| NCUC49CT5****+TDR · cold climate | NF97U090V5C*** | 17.1 | 10.0 | 9.0 | 39,500 | 217270270 |
| NCUC49CT5****+TDR · cold climate | NF98U090M5C*** | 17.1 | 10.0 | 9.0 | 39,500 | 217270510 |
| NCUC48CT5****+TDR · cold climate | NF80U110V5C*** | 17.1 | 10.0 | 8.5 | 39,500 | 217270488 |
| NCUC49CT5****+TDR · cold climate | NF95X080S4C*** | 17.1 | 11.0 | 9.0 | 39,500 | 217270499 |
| NCDC60DT5****+TDR · cold climate | NF80D110S5C*** | 17.1 | 10.0 | 8.5 | 40,000 | 217270573 |
| NCDC42BT5****+TDR · cold climate | NF96D070S4B*** | 17.0 | 10.0 | 9.0 | 39,500 | 217270542 |
| NCDC48CT5****+TDR · cold climate | NF97D110M5C*** | 17.0 | 10.0 | 9.0 | 39,500 | 217270546 |
| NCUC49CT5****+TDR · cold climate | NF98U090M4C*** | 17.0 | 10.0 | 9.0 | 39,500 | 217270498 |
| NCUC60CT5****+TDR · cold climate | NF98U110M5C*** | 17.0 | 10.0 | 8.5 | 40,000 | 217270555 |
| NCHC42BT5****+TDR · cold climate | NF80U090S4B*** | 17.0 | 10.0 | 9.0 | 39,000 | 217270517 |
| NCHC48BT5****+TDR · cold climate | NF80U090S4B*** | 17.0 | 10.0 | 9.0 | 39,500 | 217270532 |
| NCDC42BT5****+TDR · cold climate | NF80D090T4B*** | 17.0 | 10.0 | 9.0 | 39,000 | 217270541 |
| NCDC5060CT5****+TDR · cold climate | NF80D110S5C*** | 17.0 | 10.0 | 8.5 | 40,000 | 217270596 |
| NCUC48BT5****+TDR · cold climate | NF80U090S4B*** | 17.0 | 10.0 | 8.5 | 39,500 | 217270484 |
| NCUC60CT5****+TDR · cold climate | NF96U110V5C*** | 16.9 | 10.0 | 8.5 | 40,000 | 217270642 |
| NCUC60CT5****+TDR · cold climate | NF97U110V5C*** | 16.9 | 10.0 | 8.5 | 40,000 | 217270281 |
| NCUC48BT5****+TDR · cold climate | NF80U090V4B*** | 16.9 | 10.0 | 8.5 | 39,500 | 217270480 |
| NCUC49CT5****+TDR · cold climate | NF80X100S5C*** | 16.9 | 10.0 | 9.0 | 39,500 | 217270504 |
| NCUC60CT5****+TDR · cold climate | NF80L110S5C*** | 16.9 | 10.0 | 8.5 | 40,000 | 217270551 |
| NCUC60CT5****+TDR · cold climate | NF80U110T5C*** | 16.9 | 10.0 | 8.5 | 40,000 | 217270552 |
| NCUC48CT5****+TDR · cold climate | NF80X080V4B*** | 16.9 | 10.0 | 8.5 | 39,500 | 217270489 |
| NCUC48CT5****+TDR · cold climate | NF80X100V5C*** | 16.9 | 10.0 | 8.5 | 39,500 | 217270490 |
| NCUC48CT5****+TDR · cold climate | NF98U110M5C*** | 16.9 | 10.0 | 8.5 | 39,500 | 217270496 |
| NCHC42BT5****+TDR · cold climate | NF80L090S4B*** | 16.8 | 10.0 | 9.0 | 39,000 | 217270515 |
| NCHC42BT5****+TDR · cold climate | NF80U090T4B*** | 16.8 | 10.0 | 9.0 | 39,000 | 217270516 |
| NCHC48BT5****+TDR · cold climate | NF80U090V4B*** | 16.8 | 10.0 | 9.0 | 39,500 | 217270528 |
| NCHC48BT5****+TDR · cold climate | NF80L090S4B*** | 16.8 | 10.0 | 9.0 | 39,500 | 217270530 |
| NCHC48BT5****+TDR · cold climate | NF80U090T4B*** | 16.8 | 10.0 | 9.0 | 39,500 | 217270531 |
| NAM60E1TA5 · cold climate | - | 16.8 | 10.0 | 9.0 | 43,000 | 217270185 |
| NCUC49CT5****+TDR · cold climate | NF97X080V4C*** | 16.8 | 10.0 | 9.0 | 39,500 | 217270267 |
| NCHC42BT5****+TDR · cold climate | NF80U090V4B*** | 16.8 | 10.0 | 9.0 | 39,000 | 217270513 |
| NCUC48BT5****+TDR · cold climate | NF80L090S4B*** | 16.8 | 10.0 | 8.5 | 39,500 | 217270482 |
| NCUC48BT5****+TDR · cold climate | NF80U090T4B*** | 16.8 | 10.0 | 8.5 | 39,500 | 217270483 |
| NCUC60CT5****+TDR · cold climate | NF80X100V5C*** | 16.8 | 10.0 | 8.5 | 40,500 | 217270549 |
| NCUC48CT5****+TDR · cold climate | NF96U110V5C*** | 16.8 | 10.0 | 8.5 | 39,500 | 217270632 |
| NCUC48CT5****+TDR · cold climate | NF97X080V5C*** | 16.8 | 10.0 | 8.5 | 39,500 | 217270264 |
| NCUC48CT5****+TDR · cold climate | NF97U110V5C*** | 16.8 | 10.0 | 8.5 | 39,500 | 217270265 |
| NCUC49CT5****+TDR · cold climate | NF96U090S4C*** | 16.7 | 10.0 | 9.0 | 39,500 | 217270500 |
| NCHC42CT5****+TDR · cold climate | NF80U110V5C*** | 16.7 | 10.0 | 8.5 | 39,500 | 217270521 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,466/yr
- Miami, FL$1,188/yr
- Houston, TX$1,314/yr
- Atlanta, GA$1,333/yr
- Los Angeles, CA$1,298/yr
- New York, NY$3,189/yr
- Chicago, IL$2,589/yr
- Denver, CO$2,153/yr
- Seattle, WA$1,324/yr
- Minneapolis, MN$2,665/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Haier 1U60T3PE*HE?
- The Haier 1U60T3PE*HE is rated at up to 18.0 SEER2 and 11.7 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 191 certified matchups SEER2 ranges from 15.2-18.0.
- Is the Haier 1U60T3PE*HE good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 43,000 BTU/h at 5°F with a COP of 1.95, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the Haier 1U60T3PE*HE cost to run per year?
- At its rated efficiency it costs about $1,188-$3,189 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,466 in Phoenix and $2,665 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Haier 1U60T3PE*HE?
- ENERGY STAR lists 191 certified combinations for this outdoor unit. The highest-rated ones use NAM48V1TA5, NAM42V2TA5, NCUC49CT5****+TDR.
- What refrigerant does the Haier 1U60T3PE*HE use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 4 ton models
- Concord 7SCP18V60P-**A · cold climate18.0 SEER2 · 9.6 HSPF2
- TCL H48SDH20XQC · cold climate18.0 SEER2 · 9.5 HSPF2
- Trane 5TCV0X61A1 · cold climate18.0 SEER2 · 10.0 HSPF2
- Navien, Inc. NAZ17V6022A118.0 SEER2 · 9.3 HSPF2
- Sure RD18AY60AJVC · cold climate18.0 SEER2 · 10.0 HSPF2
- Daikin DH7VSA6010A · cold climate18.0 SEER2 · 9.0 HSPF2
- Trane/American Standard 5HCL6048A1000A · cold climate18.1 SEER2 · 8.5 HSPF2
- Daikin DH9VSA4810A · cold climate18.0 SEER2 · 9.0 HSPF2
See all 319 4 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of January 20, 2026. How we use the data.