HVAC Rated

4-ton central heat pump · 7SCP18V Series

Concord 7SCP18V60P-**A

Average cooling efficiency and very good heating efficiency for a 4-ton central heat pump, and certified for cold climates.

Ranks #87 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,324 a year to run in a mixed climate like Atlanta.

SEER2
18.0 Cooling efficiency over a season
Average · beats 66%
HSPF2
9.6 Heating efficiency over a season
Very good · beats 76%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
45,000 BTU/h88% of its 47°F output
Below average · beats 27%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 45,000 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 76% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 573 certified pairings.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications4 ton, R-454B
General
BrandConcord
Also sold asDucane, ALLIED
Outdoor unit model7SCP18V60P-**A
Series7SCP18V Series
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceOctober 29, 2024
Last certifiedJuly 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better18.0 (range 15.2-18.0)
EER2Efficiency at 95°F outdoors9.6-11.7
Cooling capacity42,500-55,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1-9.6
Capacity at 47°F47,000-56,500 BTU/h
Capacity at 17°F38,500-45,000 BTU/h
Capacity at 5°F39,000-45,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.75-1.95
ENERGY STAR cold climateYes
Heating output as it gets colder88% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 7AH1AV48PX- at the standard test temperatures, in BTU/h:

Certified matchups573 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 573 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
7AH1AV48PX- · cold climate-18.011.79.542,000216013466
7AH1AV48PX- · cold climate-18.011.79.542,000216013470
7AH2AE48PX- · cold climate-18.010.59.543,000216705396
7AH2AE48PX- · cold climate-18.010.59.543,000216705403
7AH2AE48PX- · cold climate-18.010.59.543,000217509120
7AH1AV48PX- · cold climate-18.011.79.542,000217509073
7AH1RE42DX- · cold climate-17.910.79.645,000218636368
7AH1RE42DX- · cold climate-17.910.79.645,000218636359
7AH1RE42DX- · cold climate-17.910.79.645,000218636350
7AH1RE48DX- · cold climate-17.910.89.444,500218636369
7AH1RE48DX- · cold climate-17.910.89.444,500218636360
7AH1RE48DX- · cold climate-17.910.89.444,500218636351
7E[C,U]49CX-**+TDR · cold climate80G2UH110CV20*17.711.09.039,000217189312
7E[C,U]49CX-**+TDR · cold climate80G2UH110CV20*17.711.09.039,000217189572
7E[C,U]49CX-**+TDR · cold climate80G2UH110CV20*17.711.09.039,000217509331
7AH1AE42PX- · cold climate-17.610.59.043,000216619128
7AH1AV42PX- · cold climate-17.611.09.043,000216619129
7AH1AV42PX- · cold climate-17.611.09.043,000216619080
7AH1AE42PX- · cold climate-17.610.59.043,000216619079
7AH1AE42PX- · cold climate-17.610.59.043,000217509087
7AH1AV42PX- · cold climate-17.611.09.043,000217509088
7E[C,U]49CX-**+TDR · cold climate92G1UH110CE16*17.611.09.039,000217450695
7E[C,U]49CX-**+TDR · cold climate92G1UH110CE16*17.611.09.039,000217450560
7E[C,U]49CX-**+TDR · cold climate92G1UH110CE16*17.611.09.039,000217509501
7AH2AE42PX- · cold climate-17.511.09.442,500216705395
7AH2AE42PX- · cold climate-17.511.09.442,500216705402
7AH2AE42PX- · cold climate-17.511.09.442,500217509119
7AH1AE48PX- · cold climate-17.511.09.043,000216619130
7AH1AE48PX- · cold climate-17.511.09.043,000216619081
7AH1AE48PX- · cold climate-17.511.09.043,000217509089
7E[C,U]49CX-**+TDR · cold climate92G1UH090CE16*17.311.09.039,500217450694
7E[C,U]49CX-**+TDR · cold climate92G1UH090CE16*17.311.09.039,500217450559
7E[C,U]49CX-**+TDR · cold climate92G1UH090CE16*17.311.09.039,500217509500
7ED48CX-**+TDR · cold climate96G1DF090CE16*17.310.09.039,000217189602
7ED48CX-**+TDR · cold climate96G1DF090CE16*17.310.09.039,000217189342
7ED48CX-**+TDR · cold climate92G1DF090CE16*17.310.09.039,000217450582
7ED48CX-**+TDR · cold climate92G1DF090CE16*17.310.09.039,000217450717
7ED48CX-**+TDR · cold climate92G1DF090CE16*17.310.09.039,000217509523
7ED48CX-**+TDR · cold climate96G1DF090CE16*17.310.09.039,000217509361
7E[C,U]49CX-**+TDR · cold climate97G2UH110CV20*17.210.09.039,500216769774
7E[C,U]49CX-**+TDR · cold climate97G2UH110CV20*17.210.09.039,500216769775
7E[C,U]49CX-**+TDR · cold climate80G1UH090CE20*17.211.09.039,500217189316
7E[C,U]49CX-**+TDR · cold climate80G1UH110CE20*17.210.09.039,500217189317
7E[C,U]49CX-**+TDR · cold climate80G1UH090CE20*17.211.09.039,500217189576
7E[C,U]49CX-**+TDR · cold climate80G1UH110CE20*17.210.09.039,500217189577
7E[C,U]49CX-**+TDR · cold climate97G2UH090CE16*17.211.09.039,000217450693
7E[C,U]49CX-**+TDR · cold climate80G1UH110CE20L*17.210.09.039,500217450696
7E[C,U]49CX-**+TDR · cold climate97G2UH090CE16*17.211.09.039,000217450558
7E[C,U]49CX-**+TDR · cold climate80G1UH110CE20L*17.210.09.039,500217450561
7E[C,U]49CX-**+TDR · cold climate97G2UH110CV20*17.210.09.039,500217509142
7E[C,U]49CX-**+TDR · cold climate80G1UH110CE20L*17.210.09.039,500217509502
7E[C,U]49CX-**+TDR · cold climate80G1UH090CE20*17.211.09.039,500217509335
7E[C,U]49CX-**+TDR · cold climate80G1UH110CE20*17.210.09.039,500217509336
7E[C,U]49CX-**+TDR · cold climate97G2UH090CE16*17.211.09.039,000217509499
7ED48CX-**+TDR · cold climate80G1DF110CE20*17.211.09.039,000217189603
7ED48CX-**+TDR · cold climate80G1DF110CE20*17.211.09.039,000217189343
7ED48CX-**+TDR · cold climate80G1DF110CE20*17.211.09.039,000217509362
7E[C,U]60CX-**+TDR · cold climate80G1UH090CE20*17.210.08.540,500217189348
7E[C,U]60CX-**+TDR · cold climate80G1UH110CE20*17.210.08.540,500217189349
7E[C,U]60CX-**+TDR · cold climate80G1UH090CE20*17.210.08.540,500217189608
Yearly running cost in 10 large cities$1,188-$3,162

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Concord 7SCP18V60P-**A?
The Concord 7SCP18V60P-**A is rated at up to 18.0 SEER2 and 11.7 EER2 for cooling and up to 9.6 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 573 certified matchups SEER2 ranges from 15.2-18.0.
Is the Concord 7SCP18V60P-**A good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 45,000 BTU/h at 5°F with a COP of 1.95, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Concord 7SCP18V60P-**A cost to run per year?
At its rated efficiency it costs about $1,188-$3,162 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,462 in Phoenix and $2,640 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Concord 7SCP18V60P-**A?
ENERGY STAR lists 573 certified combinations for this outdoor unit. The highest-rated ones use 7AH1AV48PX-, 7AH2AE48PX-, 7AH1RE42DX-.
What refrigerant does the Concord 7SCP18V60P-**A use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,450/yrYou save $937/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Concord 7SCP18V60P-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,450
Current system, per year
$2,387
You save per year
$937
Payback
18.1 years
Net after 10 years
-$7,628

Cooling $890Heating $560Electricity used: 9,061 kWhSaved vs. a minimum-efficiency heat pump: $387

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 16, 2026. How we use the data.