HVAC Rated

24,000 BTU mini-split heat pump · DIRM Series

DIRECT AIR DIRM4-27DA25-3Z

Very good cooling efficiency and average heating efficiency for a 24,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #26 of 430 24,000 BTU mini-splits for cooling efficiency, and costs about $638 a year to run in a mixed climate like Atlanta.

SEER2
25.0 Cooling efficiency over a season
Very good · beats 83%
HSPF2
10.5 Heating efficiency over a season
Average · beats 61%
EER2
13.0 Cooling efficiency on a 95°F day
Average · beats 62%
Heat at 5°F
27,000 BTU/h70% of its 47°F output
Average · beats 48%

A good fit if…

  • You want low cooling bills - its SEER2 beats 83% of mini-splits.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 27,000 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications24,000 BTU, R-454B
General
BrandDIRECT AIR
Outdoor unit modelDIRM4-27DA25-3Z
SeriesDIRM Series
TypeMini-split heat pump
Nominal size24,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceMay 15, 2024
Last certifiedMay 6, 2026
Cooling
SEER2Seasonal efficiency, higher is better25.0 (range 19.0-25.0)
EER2Efficiency at 95°F outdoors12.0-13.0
Cooling capacity26,600-28,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.0-10.5
Capacity at 47°F26,600-28,000 BTU/h
Capacity at 17°F19,800-30,000 BTU/h
Capacity at 5°F18,800-27,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00
ENERGY STAR cold climateYes
Heating output as it gets colder70% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:

Certified matchups6 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
- · cold climate25.013.09.519,000216683820
- · cold climate23.012.510.527,000215213790
- · cold climate23.012.59.318,900216683822
- · cold climate21.012.310.027,000215213792
- · cold climate21.012.09.018,800216683821
- · cold climate19.012.09.527,000215213791
Yearly running cost in 10 large cities$511-$1,573

At each state's average electricity price and the city's typical heating and cooling hours.

Questions4
What is the SEER2 rating of the DIRECT AIR DIRM4-27DA25-3Z?
The DIRECT AIR DIRM4-27DA25-3Z is rated at up to 25.0 SEER2 and 13.0 EER2 for cooling and up to 10.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 6 certified matchups SEER2 ranges from 19.0-25.0.
Is the DIRECT AIR DIRM4-27DA25-3Z good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 27,000 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the DIRECT AIR DIRM4-27DA25-3Z cost to run per year?
At its rated efficiency it costs about $511-$1,573 a year in electricity in large U.S. cities, depending on climate and local rates - for example $658 in Phoenix and $1,336 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
What refrigerant does the DIRECT AIR DIRM4-27DA25-3Z use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $668/yrYou save $724/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump DIRECT AIR DIRM4-27DA25-3Z
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$668
Current system, per year
$1,392
You save per year
$724
Payback
13.8 years
Net after 10 years
-$2,760

Cooling $380Heating $288Electricity used: 4,176 kWhSaved vs. a minimum-efficiency heat pump: $400

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 24,000 BTU models

See all 430 24,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 6, 2026. How we use the data.