HVAC Rated

1.5-ton central heat pump · DRU Series

DuraSTAR DRU1H18S2A

Very good cooling efficiency and excellent heating efficiency for a 1.5-ton central heat pump, and certified for cold climates.

Ranks #11 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $474 a year to run in a mixed climate like Atlanta.

SEER2
19.3 Cooling efficiency over a season
Very good · beats 89%
HSPF2
10.8 Heating efficiency over a season
Excellent · beats 98%
EER2
12.1 Cooling efficiency on a 95°F day
Very good · beats 74%
Heat at 5°F
19,600 BTU/h103% of its 47°F output
Average · beats 58%

A good fit if…

  • You want low cooling bills - its SEER2 beats 89% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 19,600 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 98% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications1.5 ton, R-454B
General
BrandDuraSTAR
Outdoor unit modelDRU1H18S2A
SeriesDRU Series
TypeCentral heat pump
Nominal size1.5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceDecember 8, 2020
Last certifiedJuly 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better19.3 (range 15.2-19.3)
EER2Efficiency at 95°F outdoors11.0-12.5
Cooling capacity18,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.9-10.8
Capacity at 47°F18,000-19,000 BTU/h
Capacity at 17°F13,000-15,300 BTU/h
Capacity at 5°F17,000-19,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.70-2.10
ENERGY STAR cold climateYes
Heating output as it gets colder103% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with DRUF1820S2A at the standard test temperatures, in BTU/h:

Certified matchups43 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
DRUF1820S2A · cold climate-19.312.110.819,600217465406
DRUM1824S2A · cold climate-19.012.59.718,000215374884
DRUC2417S2A · cold climateRG19080B12MPS118.011.810.619,000218072007
DRUC2417S2A · cold climateS9V2B040U3VS***18.011.79.118,000218071818
DRUC2414S2A · cold climateRG19040A10MPS117.911.19.618,000218072005
DRUC2414S2A · cold climateRG19060A10MPS117.711.39.518,000218072006
DRUC2417S2A · cold climateS9V2B080U4VS***17.411.49.418,000218071822
DRUC2417S2A · cold climateS9V2B080D4VS***17.411.49.218,000218071821
DRUC2417S2A · cold climateS9V2B060U4VS***17.411.49.018,000218071820
DRUC2417S2A · cold climateS9V2B040D3VS***17.311.49.318,000218071817
DRUC2417S2A · cold climateS9V2B060D3VS***17.311.69.118,000218071819
DRUC2417S2A · cold climateML193DF070XE36B*17.211.79.918,000218072261
DRUC2417S2A · cold climateML296UH070XV36B*17.011.19.919,000218072280
DRUC2417S2A · cold climateML193DF045XE36B*17.011.69.818,000218072260
DRUC2414S2A · cold climateRL18060A12MPS117.011.79.618,000218072063
DRUC2417S2A · cold climateML296UH045XV36B*16.911.19.618,000218072279
DRUC2417S2A · cold climateML193UH070XE36B*16.811.69.718,000218072264
DRUC2414S2A · cold climateMGV80M060A3A16.711.29.418,000218071767
DRUC2417S2A · cold climateS9X2B040D3PSB**16.611.39.518,000218071939
DRUC2417S2A · cold climateS9X1B040D3PSB**16.611.39.518,000218071825
DRUC2417S2A · cold climateRL18080B12MPS116.511.99.919,000218072064
DRUC2414S2A · cold climateRL18040A12MPS116.511.79.718,000218072062
DRUC2414S2A · cold climateMGV80M040A3A16.511.19.318,000218071766
DRUC2417S2A · cold climateML296DF045XV36B*16.411.09.718,000218072278
DRUC2417S2A · cold climateML193UH045XE36B*16.411.49.618,000218072263
DRUC2417S2A · cold climateMGV96U060B3C16.311.810.118,000218071735
DRUC2417S2A · cold climateML196UH030XE36B*16.211.29.518,000218072272
DRUC2417S2A · cold climateMGV96U080B3C16.111.710.018,000218071736
DRUC2414S2A · cold climate-16.111.79.518,000217493430
DRUC2417S2A · cold climate-16.111.79.518,000217493432
DRUC2417S2AML193UH030XE36B*16.011.28.917,000218072262
DRUC2417S2A · cold climateML196UH070XE36B*15.911.69.618,000218072274
DRUC2417S2A · cold climateRG19060B12MPS115.811.610.119,000218071720
DRUC2417S2A · cold climateML196DF045XE36B*15.611.49.318,000218072270
DRUC2417S2A · cold climateML196UH045XE36B*15.511.39.318,000218072273
DRUC2417S2A · cold climateDR95M4AT0401317S15.411.39.418,000218679562
DRUC2417S2A · cold climateDR95M4AT0601317S15.311.69.919,000218679563
DRUC2417S2A · cold climateMGV80M080B4A15.311.49.618,000218071769
DRUC2417S2A · cold climateS9X2B040U3PSB**15.311.39.318,000218071940
DRUC2417S2A · cold climateS9X1B040U3PSB**15.311.39.318,000218071826
DRUC2417S2A · cold climateML196DF070XE48B*15.211.49.518,000218072271
DRUC2417S2A · cold climateS9X2B060D3PSB**15.211.49.318,000218071941
DRUC2417S2A · cold climateS9X1B060D3PSB**15.211.49.318,000218071827
Yearly running cost in 10 large cities$438-$1,123

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the DuraSTAR DRU1H18S2A?
The DuraSTAR DRU1H18S2A is rated at up to 19.3 SEER2 and 12.1 EER2 for cooling and up to 10.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 43 certified matchups SEER2 ranges from 15.2-19.3.
Is the DuraSTAR DRU1H18S2A good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 19,600 BTU/h at 5°F with a COP of 2.10, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
How much does the DuraSTAR DRU1H18S2A cost to run per year?
At its rated efficiency it costs about $438-$1,123 a year in electricity in large U.S. cities, depending on climate and local rates - for example $533 in Phoenix and $933 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the DuraSTAR DRU1H18S2A?
ENERGY STAR lists 43 certified combinations for this outdoor unit. The highest-rated ones use DRUF1820S2A, DRUM1824S2A, DRUC2417S2A.
What refrigerant does the DuraSTAR DRU1H18S2A use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $525/yrYou save $419/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump DuraSTAR DRU1H18S2A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$525
Current system, per year
$944
You save per year
$419
Payback
16.7 years
Net after 10 years
-$2,808

Cooling $328Heating $197Electricity used: 3,283 kWhSaved vs. a minimum-efficiency heat pump: $201

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 1.5 ton models

See all 170 1.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 16, 2026. How we use the data.