HVAC Rated

1.5-ton central heat pump · SAV Series

Innovair SHV18H2BA

Very good cooling efficiency and excellent heating efficiency for a 1.5-ton central heat pump, and certified for cold climates.

Ranks #12 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $474 a year to run in a mixed climate like Atlanta.

SEER2
19.3 Cooling efficiency over a season
Very good · beats 89%
HSPF2
10.8 Heating efficiency over a season
Excellent · beats 98%
EER2
12.1 Cooling efficiency on a 95°F day
Very good · beats 74%
Heat at 5°F
19,600 BTU/h103% of its 47°F output
Average · beats 65%

A good fit if…

  • You want low cooling bills - its SEER2 beats 89% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 19,600 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 98% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications1.5 ton, R-454B
General
BrandInnovair
Outdoor unit modelSHV18H2BA
SeriesSAV Series
TypeCentral heat pump
Nominal size1.5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceDecember 18, 2019
Last certifiedNovember 20, 2025
Cooling
SEER2Seasonal efficiency, higher is better19.3 (range 16.1-19.3)
EER2Efficiency at 95°F outdoors10.8-12.5
Cooling capacity18,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.1-10.8
Capacity at 47°F18,000-19,000 BTU/h
Capacity at 17°F14,000-15,300 BTU/h
Capacity at 5°F18,000-19,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80-2.12
ENERGY STAR cold climateYes
Heating output as it gets colder103% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with SWV18BDA at the standard test temperatures, in BTU/h:

Certified matchups8 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
SWV18BDA · cold climate-19.312.110.819,600216027612
SAV18BDU · cold climate-19.012.510.118,600217966389
SAV18BDA · cold climate-19.012.59.718,000215408661
SFV18BDA · cold climate-16.812.010.519,000216768192
MAC24H1418B · cold climateC30-2-V16.810.89.118,000217618122
MAC24H1418B · cold climateC45-2-V16.611.09.519,000217618123
MAC24H1418B · cold climate-16.111.79.518,000216623504
MAC24H1718B · cold climate-16.111.79.518,000216623505
Yearly running cost in 10 large cities$438-$1,123

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Innovair SHV18H2BA?
The Innovair SHV18H2BA is rated at up to 19.3 SEER2 and 12.1 EER2 for cooling and up to 10.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 8 certified matchups SEER2 ranges from 16.1-19.3.
Is the Innovair SHV18H2BA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 19,600 BTU/h at 5°F with a COP of 2.12, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
How much does the Innovair SHV18H2BA cost to run per year?
At its rated efficiency it costs about $438-$1,123 a year in electricity in large U.S. cities, depending on climate and local rates - for example $533 in Phoenix and $933 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Innovair SHV18H2BA?
ENERGY STAR lists 8 certified combinations for this outdoor unit. The highest-rated ones use SWV18BDA, SAV18BDU, SAV18BDA.
What refrigerant does the Innovair SHV18H2BA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $525/yrYou save $419/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Innovair SHV18H2BA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$525
Current system, per year
$944
You save per year
$419
Payback
16.7 years
Net after 10 years
-$2,808

Cooling $328Heating $197Electricity used: 3,283 kWhSaved vs. a minimum-efficiency heat pump: $201

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 1.5 ton models

See all 170 1.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of November 20, 2025. How we use the data.