HVAC Rated

2-ton central heat pump · F-SERIES PLUS

Friedrich FRP15AZ24AJ2N

Below average cooling and heating efficiency for a 2-ton central heat pump, but not rated for cold climates.

Ranks #290 of 331 2 ton central heat pumps for cooling efficiency, and costs about $746 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
13,300 BTU/h56% of its 47°F output
Excellent · beats 95%

A good fit if…

  • You want a choice of indoor units - 71 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications2 ton, R-410A
General
BrandFriedrich
Outdoor unit modelFRP15AZ24AJ2N
SeriesF-SERIES PLUS
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceFebruary 2, 2023
Last certifiedJune 3, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.7
Cooling capacity22,800 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.1
Capacity at 47°F22,600-22,800 BTU/h
Capacity at 17°F14,800-16,500 BTU/h
Capacity at 5°F11,500-13,300 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.40
ENERGY STAR cold climateNo
Heating output as it gets colder56% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FRH2VZ2417STANN at the standard test temperatures, in BTU/h:

Certified matchups71 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 71 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FRH2VZ2417STANN-16.011.78.112,800213382069
TCFZ2417STANMFR962V0603A17M416.011.78.113,200213841811
TCFZ2417STANMFR97MV0603A17DH16.011.78.112,600213841816
TCFZ2417STANMFR962V0703A17M416.011.78.113,200213841819
TCFZ2417STANMFR98MV0703A17UP16.011.78.112,600213841820
TCFZ2417STANMFR962V0403A17M416.011.78.113,100213841821
TCFZ2417STANMFR98MV0603A17UP16.011.78.112,700213841824
TCFZ2417STANMFR921V0603A17M416.011.78.113,200213841827
TCFZ2417STANMFR951V0603A17M416.011.78.113,200213841829
TCFZ2417STANMFR951V0403A17UHU16.011.78.113,300213841834
TCFZ2417STANMFR921V0403A17M416.011.78.113,100213841832
TCFZ2417STANMFR951V0403A17M416.011.78.113,100213841842
TCFZ2417STANMFR951V0603A17UHU16.011.78.113,200213841841
TCFZ2417STANMFR951V0703A17M416.011.78.113,200213841843
TCFZ2417STANMFR921V0703A17M416.011.78.113,200213841845
TCFZ2417STANMFR801V0704A17UHU16.011.78.113,100213841849
TCFZ2417STANMFR802V0503A14DZ16.011.78.113,000213841852
TCFZ2417STANMFR802V1004A17UH16.011.78.113,000213841855
TCFZ2417STANMFR802V0504A17UH16.011.78.113,100213841860
TCFZ2417STANMFR801V0504A17UHS16.011.78.113,100213841863
TCFZ2417STANMFR801V0754A17UH16.011.78.113,000213841862
TCFZ2417STANMFR801V0754A17DZ16.011.78.113,100213841867
TCFZ2417STANMFR802V0754A17DZ16.011.78.113,100213841866
TCFZ2417STANMFR802V0503A14UH16.011.78.113,100213841868
TCFZ2417STANMFR801V1004A17UH16.011.78.113,000213841865
TCFZ2417STANMFR801V0503A14UH16.011.78.113,100213841870
TCFZ2417STANMFR801V0504A17UHU16.011.78.113,200213841871
TCFZ2417STANMFR802V0754A17UH16.011.78.113,000213841874
TCFZ2417STANMFR801V0503A14DZ16.011.78.113,000213841878
TCFZ2417STANMFR801V0504A17UHN16.011.78.113,100213841873
RCFZ2417STANMFR921V0403A17M416.011.78.113,100214327627
RCFZ2417STANMFR951V0403A17UHU16.011.78.113,300214327628
RCFZ2417STANMFR951V0603A17UHU16.011.78.113,200214327630
RCFZ2417STANMFR951V0403A17M416.011.78.113,100214327631
RCFZ2417STANMFR951V0703A17M416.011.78.113,200214327632
RCFZ2417STANMFR921V0703A17M416.011.78.113,200214327633
RCFZ2417STANMFR801V0704A17UHU16.011.78.113,100214327635
RCFZ2417STANMFR802V0503A14DZ16.011.78.113,000214327636
RCFZ2417STANMFR802V1004A17UH16.011.78.113,000214327637
RCFZ2417STANMFR802V0504A17UH16.011.78.113,100214327638
RCFZ2417STANMFR801V0754A17UH16.011.78.113,000214327639
RCFZ2417STANMFR801V0504A17UHS16.011.78.113,100214327640
RCFZ2417STANMFR97MV0603A17DH16.011.78.112,600214327618
RCFZ2417STANMFR962V0403A17M416.011.78.113,100214327621
RCFZ2417STANMFR962V0603A17M416.011.78.113,200214327616
RCFZ2417STANMFR962V0703A17M416.011.78.113,200214327619
RCFZ2417STANMFR98MV0703A17UP16.011.78.112,600214327620
RCFZ2417STANMFR802V0503A14UH16.011.78.113,100214327644
RCFZ2417STANMFR802V0754A17DZ16.011.78.113,100214327642
RCFZ2417STANMFR801V0503A14DZ16.011.78.113,000214327649
RCFZ2417STANMFR801V0503A14UH16.011.78.113,100214327645
RCFZ2417STANMFR951V0603A17M416.011.78.113,200214327626
RCFZ2417STANMFR802V0754A17UH16.011.78.113,000214327648
RCFZ2417STANMFR801V0504A17UHN16.011.78.113,100214327647
RCFZ2417STANMFR921V0603A17M416.011.78.113,200214327625
RCFZ2417STANMFR801V0504A17UHU16.011.78.113,200214327646
RCFZ2417STANMFR98MV0603A17UP16.011.78.112,700214327622
RCFZ2417STANMFR801V1004A17UH16.011.78.113,000214327641
RCFZ2417STANMFR801V0754A17DZ16.011.78.113,100214327643
TCFZ2417MTANMFR951V0403A17UHU16.011.77.812,000213841825
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Friedrich FRP15AZ24AJ2N: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$669-$1,780

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Friedrich FRP15AZ24AJ2N?
The Friedrich FRP15AZ24AJ2N is rated at up to 16.0 SEER2 and 11.7 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 71 certified matchups SEER2 ranges from 15.2-16.0.
Is the Friedrich FRP15AZ24AJ2N good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
How much does the Friedrich FRP15AZ24AJ2N cost to run per year?
At its rated efficiency it costs about $669-$1,780 a year in electricity in large U.S. cities, depending on climate and local rates - for example $824 in Phoenix and $1,486 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Friedrich FRP15AZ24AJ2N the same as the Friedrich FWP15AZ24AJ2N?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Friedrich FRP15AZ24AJ2N?
ENERGY STAR lists 71 certified combinations for this outdoor unit. The highest-rated ones use FRH2VZ2417STANN, TCFZ2417STANM, RCFZ2417STANM.
What refrigerant does the Friedrich FRP15AZ24AJ2N use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $817/yrYou save $359/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Friedrich FRP15AZ24AJ2N
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$817
Current system, per year
$1,176
You save per year
$359
Payback
23.7 years
Net after 10 years
-$4,912

Cooling $502Heating $315Electricity used: 5,105 kWhSaved vs. a minimum-efficiency heat pump: $85

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 3, 2026. How we use the data.