HVAC Rated

2-ton central heat pump · A5HP5

RunTru A5HP5024A1

Below average cooling and heating efficiency for a 2-ton central heat pump, but not rated for cold climates.

Ranks #295 of 331 2 ton central heat pumps for cooling efficiency, and costs about $729 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
11,800 BTU/h52% of its 47°F output
Average · beats 58%

A good fit if…

  • You want a choice of indoor units - 72 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandRunTru
Also sold asAmeristar
Outdoor unit modelA5HP5024A1
SeriesA5HP5
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceFebruary 19, 2024
Last certifiedMarch 26, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity21,200-24,400 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.1
Capacity at 47°F20,600-23,000 BTU/h
Capacity at 17°F13,700-15,300 BTU/h
Capacity at 5°F10,600-11,800 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.90-2.10
ENERGY STAR cold climateNo
Heating output as it gets colder52% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 5TXCB006AS3+TSTAT at the standard test temperatures, in BTU/h:

Certified matchups72 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 72 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
5TXCB006AS3+TSTATA952V040BU3SA16.012.08.111,200214296242
5TXCB006AS3+TSTATA952V040BU3SA16.012.08.111,200214296243
5TXCB006AS3+TSTATA952V040BU3SB16.012.08.111,200214296244
5TXCB006AS3+TSTATA952V040BU3SB16.012.08.111,200214296245
5TXCB006AS3+TSTATA952V060BU4SA16.012.08.111,200214296246
5TXCB006AS3+TSTATA952V060BU4SA16.012.08.111,200214296247
5TXCB006AS3+TSTATA952V060BU4SB16.012.08.111,200214296248
5TXCB006AS3+TSTATA952V060BU4SB16.012.08.111,200214296249
A5AHV004A1D3+TDR+TSTAT-16.012.08.111,600214296266
A5AHV004A1D3+TDR+TSTAT-16.012.08.111,600214296267
A5AHV005A1D3+TDR+TSTAT-16.012.08.111,600215611072
A5AHV005A1D3+TDR+TSTAT-16.012.08.111,600215611073
5PX*BD06AS3+TSTATA952V060BD3SB16.012.08.011,400215574548
5PX*BD06AS3+TSTATA952V060BD3SB16.012.08.011,400215574549
5PX*BD06AS3+TSTATA951X040BD3SA16.012.08.011,500215574552
5PX*BD06AS3+TSTATA951X040BD3SA16.012.08.011,500215574553
A5AHC004A1B3+TDR+TSTAT-16.012.08.011,400218154630
A5AHC004A1B3+TDR+TSTAT-16.012.08.011,400218154629
5TXCB006AS3+TSTATL8V1A040U3VSB16.012.07.811,100214296250
5TXCB006AS3+TSTATL8V1A040U3VSB16.012.07.811,100214296251
5TXCB006AS3+TSTATL8V1A060U3VSB16.012.07.811,100214296252
5TXCB006AS3+TSTATL8V1A060U3VSB16.012.07.811,100214296253
5TXCB006AS3+TSTATL8V1B080U4VSB16.012.07.811,400214296254
5TXCB006AS3+TSTATL8V1B080U4VSB16.012.07.811,400214296255
5TXCB004AS3+TSTATA951X060BU4SA15.212.08.111,400214296200
5TXCB004AS3+TSTATA951X060BU4SA15.212.08.111,400214296201
5TXCB004AS3+TSTATA951X080BU4SA15.212.08.111,200214296202
5TXCB004AS3+TSTATA951X080BU4SA15.212.08.111,200214296203
A5AHV003A1B3+TDR+TSTAT-15.212.08.111,800214296265
A5AHV003A1B3+TDR+TSTAT-15.212.08.111,800214296264
A5AHC003A1B3+TDR+TSTAT-15.212.08.111,400215611066
A5AHC003A1B3+TDR+TSTAT-15.212.08.111,400215611067
A5AHC004A1D3+TDR+TSTAT-15.212.08.111,100215611068
A5AHC004A1D3+TDR+TSTAT-15.212.08.111,100215611069
A5AHV002A1B3+TDR+TSTAT-15.212.08.111,300215611070
A5AHV002A1B3+TDR+TSTAT-15.212.08.111,300215611071
5TXCB004AS3+TSTATA801X080BM4TD15.212.07.811,300214296196
5TXCB004AS3+TSTATA801X080BM4TD15.212.07.811,300214296197
5TXCB004AS3+TSTATA951X040BU3SA15.212.07.811,100214296198
5TXCB004AS3+TSTATA951X040BU3SA15.212.07.811,100214296199
5TXCB004AS3+TSTATA952V040BU3SA15.212.07.811,200214296205
5TXCB004AS3+TSTATA952V040BU3SA15.212.07.811,200214296204
5TXCB004AS3+TSTATA952V040BU3SB15.212.07.811,200214296206
5TXCB004AS3+TSTATA952V040BU3SB15.212.07.811,200214296207
5TXCB004AS3+TSTATA952V060BU4SA15.212.07.811,200214296208
5TXCB004AS3+TSTATA952V060BU4SA15.212.07.811,200214296209
5TXCB004AS3+TSTATA952V060BU4SB15.212.07.811,200214296210
5TXCB004AS3+TSTATA952V060BU4SB15.212.07.811,200214296211
5TXCB004AS3+TSTATL8V1A040U3VSB15.212.07.811,000214296212
5TXCB004AS3+TSTATL8V1A040U3VSB15.212.07.811,000214296213
5TXCB004AS3+TSTATL8V1A060U3VSB15.212.07.811,100214296214
5TXCB004AS3+TSTATL8V1A060U3VSB15.212.07.811,100214296215
5TXCB004AS3+TSTATL8V1B080U4VSB15.212.07.811,400214296216
5TXCB004AS3+TSTATL8V1B080U4VSB15.212.07.811,400214296217
5TXCB004AS3+TSTATL9X1A050U3VSA15.211.77.810,600214296218
5TXCB004AS3+TSTATL9X1A050U3VSA15.211.77.810,600214296219
5TXCB004AS3+TSTATA801X080BM4SD15.212.07.811,300214296226
5TXCB004AS3+TSTATA801X080BM4SD15.212.07.811,300214296227
5TXCB004AS3+TSTATA801X060BM4TD15.212.07.811,300214296228
5TXCB004AS3+TSTATA801X060BM4TD15.212.07.811,300214296229
Yearly running cost in 10 large cities$685-$1,714

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the RunTru A5HP5024A1?
The RunTru A5HP5024A1 is rated at up to 16.0 SEER2 and 12.0 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 72 certified matchups SEER2 ranges from 15.2-16.0.
Is the RunTru A5HP5024A1 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
How much does the RunTru A5HP5024A1 cost to run per year?
At its rated efficiency it costs about $685-$1,714 a year in electricity in large U.S. cities, depending on climate and local rates - for example $828 in Phoenix and $1,419 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the RunTru A5HP5024A1?
ENERGY STAR lists 72 certified combinations for this outdoor unit. The highest-rated ones use 5TXCB006AS3+TSTAT, A5AHV004A1D3+TDR+TSTAT, A5AHV005A1D3+TDR+TSTAT.
What refrigerant does the RunTru A5HP5024A1 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $813/yrYou save $364/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump RunTru A5HP5024A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$813
Current system, per year
$1,177
You save per year
$364
Payback
24.7 years
Net after 10 years
-$5,364

Cooling $515Heating $299Electricity used: 5,084 kWhSaved vs. a minimum-efficiency heat pump: $85

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of March 26, 2026. How we use the data.